Plan Review Details - Permit 20050913
| Plan Review Stops For Permit 20050913 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-15 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-14 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-13 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-02 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-06-04 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-05-28 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-15 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-15 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-13 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-13 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2020-07-13 08:26:52 | APPROVED WITH A NOTE: THE NEW DRAWING DOES NOT INDICATE | | | THE DUCT SIZES. THE ORIGINAL DRAWING WITH AN APPROVAL | | | DATE OF 2002 MUST BE ON THE JOB SITE FOR THE INSPECTOR | | | AT ALL INSPECTIONS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-06-04 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-06-04 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2020-06-04 15:30:03 | CODE REFERENCE FOR BELOW NOTES IS FBC FS 107.2.1 | | 2020-06-04 15:26:20 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20050913 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE SCOPE OF WORK. THE DRAWING SUBMITTED | | | IS AN APPROVED COPY FROM 1/10/2002. THIS DRAWING IS | | | SHOWING A NEW AHU AND A/C UNIT INCLUDED AS THE SCOPE OF | | | WORK. PLEASE PROVIDE A DRAWING WITH ONLY THE WORK BEING | | | COMPLETED IN THIS PROJECT. PROVIDE INFORMATION ON THE | | | DUCTS; SIZES AND INSULATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-15 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-15 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-13 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-13 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2020-07-13 08:28:39 | NEW DRAWING MUST BE SIGNED AND DATED BY THE | | | DESIGNER.FBC FS 471.025 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-06-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-06-04 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-06-04 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2020-06-04 15:28:31 | DESIGNER MUST SIGN AND DATE THE DRAWING. |
|
|
|