Plan Review Details - Permit 20050856
Plan Review Stops For Permit 20050856
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-06-01 Cont ID  
Sent By jwitmer Date 2020-06-01 Time 09:49 Rev Time 0.00
Received By jwitmer Date 2020-06-01 Time 09:47 Sent To  
Notes
2020-06-01 09:50:17NEW BUILDING, NO ASBESTOS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-19 Cont ID  
Sent By jwitmer Date 2020-07-08 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2020-07-08 Time 13:28 Sent To  
Notes
2020-07-08 13:54:10NOTE ONLY:
 BREAK ROOM STONE COUNTERTOP SHELF
 ELIMINATED.
 SHEET: A1.3 DETAILS A-11 & K-4.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-01 Cont ID  
Sent By jwitmer Date 2020-06-01 Time 10:31 Rev Time 0.00
Received By jwitmer Date 2020-06-01 Time 09:46 Sent To  
Notes
2020-06-01 10:31:192017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050856
 ADD: 525 OKEECHOBEE BLVD. SUITE: 860
 CONT: HOLT-LEE
 TEL:954-725-4881
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY JUNE 01/2020
 ACTION: DENIED
  
 1) SHEET A1.2 L. S. SHEET ROOM 873 IS SHOWN AS THE
 BREAKROOM. SHEET A1.3 SHOWS THE DETAILS OF THE BREAK
 ROOM WITH A STONE COUNTER TOP AT 42 INCHES ABOVE FINISH
 FLOOR.
 THE PLAN DOES NOT SHOW SEATING AT THE COUNTER BUT CAN
 ONLY BE ASSUMED THAT THE COUNTER/ HI-TOP WILL BE USED
 FOR EITHER DRINKING OR EATING FOODS SINCE THIS IS A
 BREAK ROOM.
 1A) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3 OF THE 2017
 FBC-ACCESSIBILITY CODE. ADVISORY 902.1 GENERAL. DINING
 SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, TABLES,
 LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK SURFACES
 INCLUDE WRITING SURFACES, STUDY CARRELS, STUDENT
 LABORATORY STATIONS, BABY CHANGING AND OTHER TABLES OR
 FIXTURES FOR PERSONAL GROOMING, COUPON COUNTERS, AND
 WHERE COVERED BY THE ADA SCOPING PROVISIONS, EMPLOYEE
 WORK STATIONS.
  
 1A)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 1A)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
  
 1B) THE LIFE SAFETY SHEET DOES NOT SHOW COMPLIANCE WITH
 THE 2017 FBC-ACCESSIBILITY CODE NOR SHEET A1.3 WITH
 226.1 2017 ACCESSIBILITY CODE. WHERE DINING SURFACES
 ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT
 LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING
 SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-07-24 Cont ID  
Sent By jleahy Date 2020-07-24 Time 10:10 Rev Time 0.00
Received By jleahy Date 2020-07-24 Time 09:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-12 Cont ID  
Sent By jleahy Date 2020-06-12 Time 09:54 Rev Time 0.00
Received By jleahy Date 2020-06-11 Time 15:19 Sent To  
Notes
2020-06-12 09:54:51ONLY LOW VOLTAGE SYSTEM SHOW IS PHONE AND DATA JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-05-29 Cont ID  
Sent By pleduc Date 2020-05-29 Time   Rev Time 0.00
Received By pleduc Date 2020-05-28 Time 16:32 Sent To  
Notes
2020-05-29 10:09:56THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO AND CONSTRUCTION.
  
  
  
 2) ALL WORK ON THE FS & FA SHALL BE DONE UNDER SEPARATE
 PERMITS AND SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-24 Cont ID  
Sent By jwitmer Date 2020-07-24 Time 10:11 Rev Time 0.00
Received By jleahy Date 2020-07-07 Time 14:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-06-24 Time   Rev Time 0.00
Received By lmarchan Date 2020-05-27 Time 15:03 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-06-01 Cont ID  
Sent By jwitmer Date 2020-06-01 Time 10:31 Rev Time 0.00
Received By jwitmer Date 2020-06-01 Time 09:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-07-17 Cont ID  
Sent By medwards Date 2020-07-17 Time 07:21 Rev Time 0.00
Received By medwards Date 2020-07-17 Time 07:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-10 Cont ID  
Sent By medwards Date 2020-06-10 Time 09:25 Rev Time 0.00
Received By medwards Date 2020-06-10 Time 07:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-07-21 Cont ID  
Sent By ccole Date 2020-07-21 Time 16:36 Rev Time 0.00
Received By ccole Date 2020-07-21 Time 15:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-24 Cont ID  
Sent By ccole Date 2020-06-24 Time 17:09 Rev Time 0.00
Received By ccole Date 2020-06-24 Time 16:11 Sent To  
Notes
2020-06-24 17:09:221ST REVIEW FBC-2017 PLUMBING
 PERMIT 20050856
 6/24/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REFER TO TABLE 403.3 FBC P AND PROVIDE A SCHEDULE ON
 THE PLAN INDICATING THE REQUIRED AND PROVIDED PLUMBING
 FIXTURES FOR THE BUSINESS OCCUPANCY. THE DEMOLISHED
 WATER CLOSET AND LAV SINK MAY HAVE TO BE REPLACED
 DEPENDING ON THE OCCUPANT LOAD OF THE FLOOR AND THE
 NUMBER OF COMMUNAL FIXTURES AVAILABLE FOR ALL
 OCCUPANTS- SECTION 107.2.1 WPB.
  
 2) THE NEW TENANT SINK, AND THE REPLACED SINK IN THE
 ADJACENT OCCUPANCY SHALL BE INSTALLED IN ACCORDANCE
 WITH ACCESSIBILITY REQUIREMENTS UNDER SECTION 606.1-
 606.5 FBC ACC. PROVIDE DETAILS AND SPECIFICATIONS TO
 INDICATE COMPLIANCE.
  
 3) CONNECTING THE NEW SINK DRAIN TO THE EXISTING
 SANITARY MAY REQUIRE THE FLOOR SLAB TO BE X-RAYED IN
 ORDER TO LOCATE POST STRESSED TENDONS OR STEEL
 REINFORCEMENTS. PLEASE PROVIDE ADDITIONAL INFORMATION
 ON THE PLAN,
  
 4) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB
 WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE
 AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION
 714.4.1.2 FBC-B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-24 Cont ID  
Sent By jleahy Date 2020-07-24 Time 10:11 Rev Time 0.00
Received By jleahy Date 2020-07-24 Time 10:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-06-10 Cont ID  
Sent By medwards Date 2020-06-10 Time 09:31 Rev Time 0.00
Received By medwards Date 2020-06-10 Time 09:25 Sent To  
Notes
***NONE***