| Plan Review Stops For Permit 20050766 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-30 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-30 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2020-07-30 12:28:36 | PROVISO: CONTRACTOR TO PROVIDE LETTER |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-09 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2020-06-09 07:56:18 | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | ASBESTOS REVIEW DENIED: | | | | | | ASBESTOS REQUIREMENTS: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-20 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-20 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-09 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-08 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2020-06-09 16:18:30 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, ON PAGE A0.01, ADD THE SECTION FROM THE | | | EXISTING BUILDING CODE THAT YOU ARE REFERENCING | | | (EXAMPLE: ALTERATION LEVEL 1, 2, OR 3). | | | THIS WILL HELP TO ADDRESS CONCERNS OF POTENTIAL CODE | | | VIOLATIONS SUCH AS: FBC B 1016.2 EGRESS THROUGH | | | INTERVENING SPACES. | | | | | | FBC B 107, PLEASE ADDRESS THE CONCERN OF ELEVATOR | | | LOBBIES IN EXISTING HIGH RISE CONSTRUCTION AS IT | | | APPEARS THAT A DOOR MAY BE REQUIRED SEPARATING THE | | | CENTER CORRIDOR FROM THE ELEVATOR LOBBY. | | | (THIS ISSUE HAS COME UP UNDER PRIOR PERMITS FROM OTHER | | | FLOORS WITHIN THIS BUILDING, PER CHIEF PLANS EXAMINER | | | S. HILL) | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-17 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-16 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-06-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-05 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-05 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-16 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-05-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-05-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-05-29 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2020-05-29 11:13:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 1.11 - WITHIN THE LAB ROOM THERE ARE TWO | | | HOODS INDICATED THAT ARE NOT ON THE MECHANICAL PLAN | | | SHEETS. | | | | | | WHAT IS THE FUNCTION OF THESE HOODS AND DO THEY HAVE | | | ANY VENTING/EXHAUSTED RELEATED FEATURES TO THEM? | | | | | | PLEASE PROVIDE DETAILS/SPEC SHEETS AND ADD THEM TO THE | | | MECHANICAL PLANS IF APPLICABLE. | | | | | | | | | | | | 2) SHEET AO.14 - WITHIN THE DOOR SCHEDULE UNDER | | | HARDWARE GROUP THERE ARE INDICATIONS OF TBD & N/A. | | | | | | ON REVIEW OF THE BACK UP INFORMATION LABORATORY SUMMARY | | | THERE IS INDICATIONS OF: "LABORATORY FACILITIES | | | (SECONDARY BARRIERS) # 1 LABORATORY DOORS SHOULD BE | | | SELF-CLOSING AND HAVE LOCKS IN ACCORDANCE WITH THE | | | COMPNAY PLOICIES." | | | | | | THERE ARE NO INDICATIONS OF SELF-CLOSERS WITHIN THE | | | DOOR SCHEDULE. | | | | | | THERE ARE NO INDICATIONS OF DOO & LOCKS/LATCHING | | | HARDWARE. | | | | | | PER NFPA 101 CH 7, MEANS OF EGRESS | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM | | | THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. | | | 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY | | | TO DOOR | | | LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER EXPOSURE TO | | | ELEVATED | | | TEMPERATURE IN ACCORDANCE WITH THE LISTING, BASED ON | | | LABORATORY | | | FIRE TEST PROCEDURES. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A | | | TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM | | | THE EGRESS | | | SIDE. | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | | | | 3) ELECTRICAL SHEETS - FOR INFOMATIONAL PURPOSES ONLY | | | | | | THERE ARE NO INDICATIONS OF ACCESS CONTROL WITHIN THE | | | PORJECT. | | | | | | SHOULD ACCESS CONTROL BE CONSIDERED, IT SHALL BE | | | SUBMITTED UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PROVIDE AND APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | PLEASE ENSURE COMPLINACE IF PROPOSED. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-07-21 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-07-21 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-06-11 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-05-28 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-09 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-08 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-18 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-18 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-06-10 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-06-05 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2020-06-10 17:43:45 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20050766 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE BIO SAFETY PDF DOCUMENT IS A BLANK PAGE, PLEASE | | | UPLOAD DOCUMENT. FBC FS 107.2.1 | | | | | | 2) SHEET M0.1: PLEASE PROVIDE OUTDOOR AIR CALCULATIONS | | | INCLUDING THE SYSTEM VENTILATION EFFICIENCY. FBC | | | M403.3.1.1.2.3.2 | | | | | | 3) PLEASE PROVIDE ENERGY CODE CALCULATIONS. FBC EC | | | C403.2 | | | | | | 4) PLEASE PROVIDE A LIST OF HAZARDOUS MATERIALS WITH | | | QUANTITIES OF EACH STORED FOR THIS FACILITY. FBC FS | | | 107.2.1 | | | | | | 5) PLEASE PROVIDE SPEC SHEETS FOR ALL EQUIPMENT USED IN | | | THESE AREAS. FBC FS 107.2.1 | | | | | | 6) ACCORDING TO THE A SHEETS THESE WALLS HAVE A FIRE | | | RATING OF 1 HR. PLEASE SHOW ALL DUCT WORK PASSING | | | THROUGH THESE WALLS ARE PROTECTED WITH THE REQUIRED FD. | | | FBC M 607.5 | | | | | | 7) PLEASE SHOW HOW AHU-1 IS PROVIDING VENTILATION FOR | | | THE AREA. SHOW DUCT WORK ON THE DRAWING. FBC FS 107.2.1 | | | | | | 8) PLEASE SHOW HOW THE HOODS LOCATED IN THE LABS ARE | | | EXHAUSTING THE AIR AND SHOW THE EXHAUST TERMINATION | | | LOCATION. FBC FS 107.2.1 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-07-21 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-07-21 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2020-07-21 11:15:12 | 20050766 625 N FLAGLER DR # 625 | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | EXISTING DRINKING FOUNTAIN TO REMAIN AS IS; SEE A0.02 | | | AND A1.11 | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-06-09 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-06-09 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2020-06-09 12:30:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 20050766 625 N FLAGLER DR # 625 | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | | APPROVAL. | | | | | | 1. PER WPB FBC 107.2.1, PROVIDE ON PLANS THE | | | LOCATION(S) OF MINIMUM PLUMBING FACILITIES FOR THE | | | BUSINESS OCCUPANCY PER FBC PL 403.1, TABLE 403.1 AS | | | FOLLOW: | | | A. FBC PL 410.3 REQUIRES NO FEWER THAN TWO DRINKING | | | FOUNTAINS. ONE DRINKING FOUNTAIN SHALL COMPLY WITH THE | | | REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR AND ONE | | | DRINKING FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS | | | FOR STANDING PERSONS. A SINGLE DRINKING FOUNTAIN WITH | | | TWO SEPARATE SPOUTS THAT COMPLIES WITH THE REQUIREMENTS | | | FOR PEOPLE WHO USE A WHEELCHAIR AND STANDING PERSONS | | | SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE | | | DRINKING FOUNTAINS. COMPLY WITH FBC ACC 211.2 AND | | | SECTION 602. | | | B. ONE (1) SERVICE SINK | | | | | | 2. THE BSL-2 RESEARCH LABORATORY SUMMARY SUBMITTED IN | | | SUPPORTING DOCUMENTS CALL OUT AN AUTOCLAVE. PER WPB FBC | | | 107.2.1, PROVIDE MANUFACTURER?S | | | SPECIFICATION/INSTALLATION MANUAL SHOWING COMPLIANCE | | | WITH FBC PL 422.9 AND SHOW LOCATION ON THE PLANS. | | | 3. THE BSL-2 RESEARCH LABORATORY SUMMARY SUBMITTED IN | | | SUPPORTING DOCUMENTS CALL OUT AND SHOW TWO (2) | | | EMERGENCY EYEWASH STATIONS. PER WPB FBC 107.2.1, | | | PROVIDE MANUFACTURER?S SPECIFICATION/INSTALLATION | | | MANUAL SHOWING COMPLIANCE WITH FBC PL 411.1 AND SHOW | | | LOCATIONS ON THE PLANS. | | | | | | A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT | | | THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A | | | RESPONSE NARRATIVE ADDRESSING THE PLUMBING COMMENTS | | | FROM THE FIRST REVIEW. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS | | | REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | | | | 20050766 625 N FLAGLER DR # 625 | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-20 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-20 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-09 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|