Plan Review Details - Permit 20050739
Plan Review Stops For Permit 20050739
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-10-25 Cont ID  
Sent By jwitmer Date 2020-10-25 Time 13:16 Rev Time 0.00
Received By jwitmer Date 2020-10-25 Time 13:02 Sent To  
Notes
2020-10-25 13:16:17BUILDING PROVISO:THE SUBMITTED SKETCH SHOWS BOTH BOLTED
 AND WELDED CONNECTIONS, PLEASE SHOW COMPLIANCE WITH
 WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
 WELDING CERTIFICATES WILL NEED TO BE ON THE JOBSITE AT
 TIME OF INSPECTION SO THE INSPECTOR CAN BRING THEM INTO
 THE CITY.
 J. WITMER BUILDING PLANS EXAMINER

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 16:14 Rev Time 0.00
Received By jwitmer Date 2020-09-21 Time 15:59 Sent To  
Notes
2020-09-21 16:13:542017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050739
 ADD: 120 S. OLIVE AVE.
 CONT: PETTERSON CONSTTRUCTION GROUP
 TEL: 954-649-5986
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: MON.SEPT. 21ST/ 2020
 ACTION: DENIED
  
 1) I SPOKE WITH CHASE AS TO THE REQUIREMENT FOR A
 CONTRACTOR TAKING RESPONSIBILITY FOR THE DRAWINGS,
 PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER.2B)
 2ND REQUEST. THE CONTRACTOR IS REPLACING THE DECK ONLY
 NOT ANY STEEL FRAME WORK. WITH THAT BEING SAID THE
 CONTRACTOR HAS TO TAKE RESPONSIBILITY FOR THEIR DESIGN.
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
 2) BUILDING PROVISO:THE SUBMITTED SKETCH SHOWS BOTH
 BOLTED AND WELDED CONNECTIONS, PLEASE SHOW COMPLIANCE
 WITH WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
 WELDING CERTIFICATES WILL NEED TO BE ON THE JOBSITE AT
 TIME OF INSPECTION SO THE INSPECTOR CAN BRING THEM INTO
 THE CITY.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-12 Cont ID  
Sent By jwitmer Date 2020-08-12 Time 16:02 Rev Time 0.00
Received By jwitmer Date 2020-08-12 Time 15:33 Sent To  
Notes
2020-08-12 16:08:272017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050739
 ADD: 120 S. OLIVE AVE.
 CONT: PETTERSON CONSTTRUCTION GROUP
 TEL: 954-649-5986
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. AUGUST 12TH/ 2020
 ACTION: DENIED
  
 1) COMPLIED.
  
 2A) COMPLIED, DECK ONLY BEING REPLACED WITH SAME
 THICKNESS OF STEEL.
  
 2B) 2ND REQUEST. THE CONTRACTOR IS REPLACING THE DECK
 ONLY NOT ANY STEEL FRAME WORK. WITH THAT BEING SAID THE
 CONTRACTOR HAS TO TAKE RESPONSIBILITY FOR THEIR DESIGN.
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
  
  
  
 1ST ROUND OF COMMENTS. THE PROPOSED DESIGNER ALSO HAS
 NOT INCLUDED ANY CALCULATIONS FOR THE LOADS TO BE
 CARRIED BY THE NON-CEMETERY LOADING OF THE WALL
 BRACING. CERTIFICATION BY CONTRACTORS CAN ONLY OCCUR ON
 DRAWINGS FOR ONE AND TWO FAMILY DWELLINGS AND INTERIOR
 WORK THAT DOES NOT INCLUDE STRUCTURAL ENGINEERING.
 107.4.3.2 CERTIFICATION BY CONTRACTORS AND F. S.
 471.003?QUALIFICATIONS FOR PRACTICE ENGINEERING ;(1) NO
 PERSON OTHER THAN A DULY LICENSED ENGINEER SHALL
 PRACTICE ENGINEERING.
  
 3) BUILDING PROVISO:THE SUBMITTED SKETCH SHOWS BOTH
 BOLTED AND WELDED CONNECTIONS, PLEASE SHOW COMPLIANCE
 WITH WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
 WELDING CERTIFICATES WILL NEED TO BE ON THE JOBSITE AT
 TIME OF INSPECTION SO THE INSPECTOR CAN BRING THEM INTO
 THE CITY.
  
 4) COMPLIED.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-21 Cont ID  
Sent By jwitmer Date 2020-06-21 Time 15:30 Rev Time 0.00
Received By jwitmer Date 2020-06-21 Time 14:17 Sent To  
Notes
2020-06-21 15:51:422017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050739
 ADD: 120 S. OLIVE AVE.
 CONT: PETTERSON CONSTTRUCTION GROUP
 TEL: 954-649-5986
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN. JUNE 21ST/ 2020
 ACTION: DENIED
  
 1) THE SUBMITTED VALUE FOR THE PROPOSED PROJECT IS LOW
 FOR THE FABRICATION AND INSTALLATION OF THIS PROJECT
 AND REQUIRED ENGINEERING.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 109.3*
 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) THE SUBMITTED SKETCH OF WHAT APPEARS TO BE A
 MID-LANDING, IS THE ONLY DOCUMENT SUBMITTED FOR PLANS.
 THERE IS NO SITE PLAN SHOWING THE LOCATION OF THE FIRE
 ESCAPE, DISTANCE BETWEEN BUILDINGS, NOR IS THERE AN
 ELEVATION VIEW SHOWING THE LOCATION OF THIS MID-LANDING
 HEIGHT ABOVE GRADE OR CLEARANCE AT THE BOTTOM OF THE
 WALL BRACE LOCATED BELOW THE LANDING. THE PLANS ARE
 ALSO SILENT AS TO WHAT ANCHORS ARE GOING TO BE USED IN
 THE INSTALLATION OR IF THE WALL IS TERRA-COTTA WALL
 SYSTEM COMMONLY USED IN THAT TIME PERIOD OR OTHER
 MATERIAL? THERE IS NO MENTION OF THE EXISTING GUARDRAIL
 AT THE PROPOSED LANDING? THE PROPOSED DESIGNER ALSO HAS
 NOT INCLUDED ANY CALCULATIONS FOR THE LOADS TO BE
 CARRIED BY THE NON-CEMETERY LOADING OF THE WALL
 BRACING. CERTIFICATION BY CONTRACTORS CAN ONLY OCCUR ON
 DRAWINGS FOR ONE AND TWO FAMILY DWELLINGS AND INTERIOR
 WORK THAT DOES NOT INCLUDE STRUCTURAL ENGINEERING.
 107.4.3.2 CERTIFICATION BY CONTRACTORS AND F. S.
 471.003?QUALIFICATIONS FOR PRACTICE ENGINEERING ;(1) NO
 PERSON OTHER THAN A DULY LICENSED ENGINEER SHALL
 PRACTICE ENGINEERING.
  
 3) THE SUBMITTED SKETCH SHOWS BOTH BOLTED AND WELDED
 CONNECTIONS, PLEASE SHOW COMPLIANCE WITH WELDED OR
 BOLTED CONNECTIONS. THE CONTRACTOR IS REQUIRED TO
 PROVIDE WELD PROCEDURE SPECIFICATIONS & WELDER OPERATOR
 PERFORMANCE QUALIFICATION RECORDS IN ACCORDANCE WITH
 THE REFERENCED STANDARDS AT TIME OF INSPECTION. THIRD
 PARTY CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 4) THE SUBMITTED SKETCH WILL NEED TO SHOW COMPLIANCE
 WITH THE CALCULATION FOR THE FIRE ESCAPE AND LIVE LOADS
 FOR 100 PSF 2017 FBC-B TABLE 1607.1(13) FIRE ESCAPES.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2020-10-23 Cont ID  
Sent By pleduc Date 2020-10-23 Time   Rev Time 0.00
Received By pleduc Date 2020-10-23 Time 10:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-09-17 Cont ID  
Sent By pleduc Date 2020-09-17 Time   Rev Time 0.00
Received By pleduc Date 2020-09-17 Time 11:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2020-08-10 Cont ID  
Sent By pleduc Date 2020-08-10 Time   Rev Time 0.00
Received By pleduc Date 2020-08-10 Time 13:19 Sent To  
Notes
2020-08-10 13:23:46*******PREVIOUS FIRE COMMENTS WERE NOT SPECICALLY
 ADDRESSED***********
  
 PREVIOUS COMMENTS RESUBMITTED:
  
  
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE SUBMITTED SHEET INDICATES THE "ALL" DECKS &
 BOLTS WITH NO INDICATION OF HOW MANY OR LEVELS.
  
 PLEASE PROVIDE A HORIZONTAL VIEW OF THE ENTIRE ESCAPE
 STAIR AND THE SPECIFIC LOCATIONS OF THE PROPOSED
 REPAIRS.
  
  
 2) THERE ARE NO INDICATIONS OF HOW LONG THIS PROPOSED
 REPAIR WILL TAKE AND WHAT MEASURES WILL BE PUT IN PLACE
 TO AVOID USE OF THE STAIR WHILE IT IS IN AN UNSAFE
 STATE.
  
 PER NFPA 101
  
 4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT
 OPERATIONS.
 4.6.10.1* BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE
 PERMITTED TO
 BE OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS,
 OR ADDITIONS
 ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE
 PROTECTION
 FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR
 THE PORTION
 OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES
 ACCEPTABLE TO
 THE AUTHORITY HAVING JURISDICTION ARE IN PLACE.
 4.6.10.2* IN BUILDINGS UNDER CONSTRUCTION, ADEQUATE
 ESCAPE
 FACILITIES SHALL BE MAINTAINED AT ALL TIMES FOR THE USE
 OF
 CONSTRUCTION WORKERS. ESCAPE FACILITIES SHALL CONSIST
 OF DOORS,
 WALKWAYS, STAIRS, RAMPS, FIRE ESCAPES, LADDERS, OR
 OTHER APPROVED
 MEANS OR DEVICES ARRANGED IN ACCORDANCE WITH THE
 GENERAL
 PRINCIPLES OF THE CODE INSOFAR AS THEY CAN REASONABLY
 BE APPLIED
 TO BUILDINGS UNDER CONSTRUCTION.
  
 PLEASE PROVIDE SPECIFIC DETAILS
  
  
  
 3) THERE IS NO INDICATIONS OF COMPLIANCE WITH NFPA 101,
 CH 7 MEANS OF EGRESS
  
 7.2.8.4 STAIR DETAILS. FIRE ESCAPE STAIRS SHALL COMPLY
 WITH THE
 REQUIREMENTS OF TABLE 7.2.8.4(A). REPLACEMENT OF FIRE
 ESCAPE
 STAIRS SHALL COMPLY WITH THE REQUIREMENTS OF TABLE
 7.2.8.4(B).
  
 7.2.8.6.2 THE AUTHORITY HAVING JURISDICTION SHALL BE
 PERMITTED TO
 APPROVE ANY EXISTING FIRE ESCAPE STAIR THAT HAS BEEN
 SHOWN BY LOAD
 TEST OR OTHER SATISFACTORY EVIDENCE TO HAVE ADEQUATE
 STRENGTH.
  
 PLEASE ENSURE COMPLAINCE WITH AN APPLICABLE NOTE AND
 PROVIDE DETAILS.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-06-22 Cont ID  
Sent By pleduc Date 2020-06-22 Time   Rev Time 0.00
Received By pleduc Date 2020-06-22 Time 08:46 Sent To  
Notes
2020-06-22 09:13:48THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE SUBMITTED SHEET INDICATES THE "ALL" DECKS &
 BOLTS WITH NO INDICATION OF HOW MANY OR LEVELS.
  
 PLEASE PROVIDE A HORIZONTAL VIEW OF THE ENTIRE ESCAPE
 STAIR AND THE SPECIFIC LOCATIONS OF THE PROPOSED
 REPAIRS.
  
  
 2) THERE ARE NO INDICATIONS OF HOW LONG THIS PROPOSED
 REPAIR WILL TAKE AND WHAT MEASURES WILL BE PUT IN PLACE
 TO AVOID USE OF THE STAIR WHILE IT IS IN AN UNSAFE
 STATE.
  
 PER NFPA 101
  
 4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT
 OPERATIONS.
 4.6.10.1* BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE
 PERMITTED TO
 BE OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS,
 OR ADDITIONS
 ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE
 PROTECTION
 FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR
 THE PORTION
 OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES
 ACCEPTABLE TO
 THE AUTHORITY HAVING JURISDICTION ARE IN PLACE.
 4.6.10.2* IN BUILDINGS UNDER CONSTRUCTION, ADEQUATE
 ESCAPE
 FACILITIES SHALL BE MAINTAINED AT ALL TIMES FOR THE USE
 OF
 CONSTRUCTION WORKERS. ESCAPE FACILITIES SHALL CONSIST
 OF DOORS,
 WALKWAYS, STAIRS, RAMPS, FIRE ESCAPES, LADDERS, OR
 OTHER APPROVED
 MEANS OR DEVICES ARRANGED IN ACCORDANCE WITH THE
 GENERAL
 PRINCIPLES OF THE CODE INSOFAR AS THEY CAN REASONABLY
 BE APPLIED
 TO BUILDINGS UNDER CONSTRUCTION.
  
 PLEASE PROVIDE SPECIFIC DETAILS
  
  
  
 3) THERE IS NO INDICATIONS OF COMPLIANCE WITH NFPA 101,
 CH 7 MEANS OF EGRESS
  
 7.2.8.4 STAIR DETAILS. FIRE ESCAPE STAIRS SHALL COMPLY
 WITH THE
 REQUIREMENTS OF TABLE 7.2.8.4(A). REPLACEMENT OF FIRE
 ESCAPE
 STAIRS SHALL COMPLY WITH THE REQUIREMENTS OF TABLE
 7.2.8.4(B).
  
 7.2.8.6.2 THE AUTHORITY HAVING JURISDICTION SHALL BE
 PERMITTED TO
 APPROVE ANY EXISTING FIRE ESCAPE STAIR THAT HAS BEEN
 SHOWN BY LOAD
 TEST OR OTHER SATISFACTORY EVIDENCE TO HAVE ADEQUATE
 STRENGTH.
  
 PLEASE ENSURE COMPLAINCE WITH AN APPLICABLE NOTE AND
 PROVIDE DETAILS.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2020-10-30 Cont ID  
Sent By fmittner Date 2020-10-30 Time 12:24 Rev Time 0.00
Received By fmittner Date 2020-10-30 Time 12:24 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-09-25 Cont ID  
Sent By fmittner Date 2020-09-25 Time 10:44 Rev Time 0.00
Received By fmittner Date 2020-09-25 Time 10:44 Sent To  
Notes
2020-09-25 10:44:26DECK ONLY NOT FRAME

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2020-08-26 Cont ID  
Sent By fmittner Date 2020-08-26 Time 13:10 Rev Time 0.00
Received By fmittner Date 2020-08-26 Time 13:10 Sent To  
Notes
2020-08-26 13:11:31SEE COMMENTS FROM FIRST REVIEW

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-07-02 Cont ID  
Sent By fmittner Date 2020-07-02 Time 17:06 Rev Time 0.00
Received By fmittner Date 2020-07-02 Time 17:06 Sent To  
Notes
2020-07-02 17:07:11NEED SUPPLEMENTAL INFO....PHOTOS OF EXISITNG TO COMPARE
 TO PROPSED

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-11-13 Cont ID  
Sent By medwards Date 2020-11-13 Time 10:21 Rev Time 0.00
Received By medwards Date 2020-10-22 Time 15:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-22 Cont ID  
Sent By lmarchan Date 2020-10-22 Time 13:54 Rev Time 0.00
Received By lmarchan Date 2020-09-14 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-04 Cont ID  
Sent By lmarchan Date 2020-09-04 Time 14:24 Rev Time 0.00
Received By lmarchan Date 2020-08-07 Time 13:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-06 Cont ID  
Sent By shill Date 2020-07-06 Time 14:44 Rev Time 0.00
Received By shill Date 2020-06-12 Time 14:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2020-11-13 Cont ID  
Sent By medwards Date 2020-11-13 Time 10:16 Rev Time 0.00
Received By medwards Date 2020-11-13 Time 10:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-12 Cont ID  
Sent By jwitmer Date 2020-08-12 Time 16:03 Rev Time 0.00
Received By jwitmer Date 2020-08-12 Time   Sent To  
Notes
2020-08-12 16:09:19107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-06 Cont ID  
Sent By shill Date 2020-07-06 Time 14:43 Rev Time 0.00
Received By shill Date 2020-07-06 Time 14:43 Sent To  
Notes
2020-07-06 14:44:21SIGNATURE REVIEW TO BE DONE ON NEXT REVIEW CYCLE
  

Review Stop Z ZONING
Rev No 3 Status P Date 2020-10-22 Cont ID  
Sent By elevesqu Date 2020-10-22 Time 13:44 Rev Time 0.00
Received By elevesqu Date 2020-10-22 Time 13:44 Sent To  
Notes
2020-10-22 13:45:02ON EAST SIDE OF BUILDING PER CONTRACTOR

Review Stop Z ZONING
Rev No 2 Status F Date 2020-08-11 Cont ID  
Sent By elevesqu Date 2020-08-11 Time 15:35 Rev Time 0.00
Received By elevesqu Date 2020-08-11 Time 15:34 Sent To  
Notes
2020-08-11 15:34:58REPEAT COMMENT:
  
 PLES SUBMIT SURVEY OF PROPERTY
  
 PLEASE INDICATE LOCATION FOR LANDING/S WITHIN STRUCTURE
 AND ON SITE
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By elevesqu Date 2020-06-16 Time 15:18 Rev Time 0.00
Received By elevesqu Date 2020-06-16 Time 15:18 Sent To  
Notes
2020-06-16 15:18:30PLES SUBMIT SURVEY OF PROPERTY
  
 PLEASE INDICATE LOCATION FOR LANDING/S WITHIN STRUCTURE
 AND ON SITE
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]