| Plan Review Stops For Permit 20050562 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-31 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-03 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-06-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-17 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-17 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-03 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-03 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-06-19 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-06-19 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2020-06-19 14:15:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THERE ARE DISCREPANCIES ON SEVERAL SHEETS. E-601 AND | | | E-604 SHOW THERE IS ONE METER EXISTING, WHILE E-603 AND | | | E-606 SHOW THERE ARE TWO METERS. PROVIDE CLARIFICATION | | | AND CORRECTIONS AS NEEDED. WPB FBC 107.2.1 | | | 2. PROVIDE WIRE SIZES FOR ALL NEW WIRING SHOWN ON PLAN. | | | NEC 215.5, 310.15(B)(16); WPB FBC 107.2.1 | | | 3. WHAT TYPE OF VOLTAGE (AC OR DC) WILL BE RUN BETWEEN | | | THE BUILDINGS IN THE TRENCH, WHAT TYPE OF CONDUIT WILL | | | BE USED? WHERE IS THE OVERCURRENT PROTECTION FOR THESE | | | CONDUCTORS? PROVIDE CLARIFICAITON. WPB FBC 107.2.1; NEC | | | 690.9, 690.10, 690.31(G). | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-03 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-15 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-06-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-01 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-13 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-13 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2020-08-13 17:28:01 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | SIGNATURE REVIEW APPROVED BY ORIGINAL PAPER SUBMITTALS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-31 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-31 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2020-07-31 15:41:51 | DOCUMENT/DRAWING LABELED "ANDERSON_SESTAMPED..." AND | | | "PAGES FROM SP1-SITE PLAN ANDERSON 1.PDF" IN PROJECTDOX | | | = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER OR ARCHITECT DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-06-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-17 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-06-17 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2020-06-19 11:35:22 | DIGITALLY SIGNED DOCUMENTS IN THE SIGNATURES FOLDER. | | | EACH SHEET OF PLAN SHOULD BE DIGITALLY SIGNED/SEALED | | | AND UPLOADED SEPARATELY. ANY NEW SHEETS SUBMITTED WILL | | | NEED TO BE CHECKED. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED (AND SEALED FOR DESIGN | | | PROFESSIONALS) BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED OR SIGNED/SEALED | | | PAPER SET MAY BE SUPPLIED TO THE BUILDING DEPARTMENT | | | WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | | | | | | | | | 2020-06-17 09:05:45 | DRAWINGS NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO | | | BE USED IN ELECTRONIC PLAN REVIEW. DRAWINGS DO NOT SHOW | | | IN "ADOBE READER" AS DIGITALLY/ELECTRONICALLY SIGNED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-07-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-07-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-06-05 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-06-05 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-06-05 |
Time |
|
Sent To |
I |
|
| Notes |
|
|