Plan Review Details - Permit 20050562
Plan Review Stops For Permit 20050562
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By rmcphers Date 2020-07-31 Time 15:34 Rev Time 0.00
Received By jleahy Date 2020-08-03 Time 16:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-06-17 Cont ID  
Sent By rmcphers Date 2020-06-17 Time 09:02 Rev Time 0.00
Received By rmcphers Date 2020-06-17 Time 08:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-03 Cont ID  
Sent By jleahy Date 2020-08-03 Time 16:25 Rev Time 0.00
Received By jleahy Date 2020-08-03 Time 16:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-19 Cont ID  
Sent By jpearson Date 2020-06-19 Time 14:54 Rev Time 0.00
Received By jpearson Date 2020-06-19 Time 11:31 Sent To  
Notes
2020-06-19 14:15:12CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. THERE ARE DISCREPANCIES ON SEVERAL SHEETS. E-601 AND
 E-604 SHOW THERE IS ONE METER EXISTING, WHILE E-603 AND
 E-606 SHOW THERE ARE TWO METERS. PROVIDE CLARIFICATION
 AND CORRECTIONS AS NEEDED. WPB FBC 107.2.1
 2. PROVIDE WIRE SIZES FOR ALL NEW WIRING SHOWN ON PLAN.
 NEC 215.5, 310.15(B)(16); WPB FBC 107.2.1
 3. WHAT TYPE OF VOLTAGE (AC OR DC) WILL BE RUN BETWEEN
 THE BUILDINGS IN THE TRENCH, WHAT TYPE OF CONDUIT WILL
 BE USED? WHERE IS THE OVERCURRENT PROTECTION FOR THESE
 CONDUCTORS? PROVIDE CLARIFICAITON. WPB FBC 107.2.1; NEC
 690.9, 690.10, 690.31(G).
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-03 Cont ID  
Sent By jleahy Date 2020-08-03 Time 16:25 Rev Time 0.00
Received By jleahy Date 2020-07-15 Time 15:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-06-19 Time   Rev Time 0.00
Received By lmarchan Date 2020-06-01 Time 15:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-08-13 Cont ID  
Sent By pvalenti Date 2020-08-13 Time 17:26 Rev Time 0.00
Received By pvalenti Date 2020-08-13 Time 17:26 Sent To  
Notes
2020-08-13 17:28:01PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 SIGNATURE REVIEW APPROVED BY ORIGINAL PAPER SUBMITTALS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-31 Cont ID  
Sent By rmcphers Date 2020-07-31 Time 15:40 Rev Time 0.00
Received By rmcphers Date 2020-07-31 Time 15:40 Sent To  
Notes
2020-07-31 15:41:51DOCUMENT/DRAWING LABELED "ANDERSON_SESTAMPED..." AND
 "PAGES FROM SP1-SITE PLAN ANDERSON 1.PDF" IN PROJECTDOX
 = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER OR ARCHITECT DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP
 BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS
 ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE
 REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN
 REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING
 [email protected] AND ASKING FOR THE FORM

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-19 Cont ID  
Sent By rmcphers Date 2020-06-17 Time 09:02 Rev Time 0.00
Received By jpearson Date 2020-06-17 Time 09:02 Sent To  
Notes
2020-06-19 11:35:22DIGITALLY SIGNED DOCUMENTS IN THE SIGNATURES FOLDER.
 EACH SHEET OF PLAN SHOULD BE DIGITALLY SIGNED/SEALED
 AND UPLOADED SEPARATELY. ANY NEW SHEETS SUBMITTED WILL
 NEED TO BE CHECKED.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 IS REQUIRED TO BE SIGNED (AND SEALED FOR DESIGN
 PROFESSIONALS) BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED OR SIGNED/SEALED
 PAPER SET MAY BE SUPPLIED TO THE BUILDING DEPARTMENT
 WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
  
  
  
2020-06-17 09:05:45DRAWINGS NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO
 BE USED IN ELECTRONIC PLAN REVIEW. DRAWINGS DO NOT SHOW
 IN "ADOBE READER" AS DIGITALLY/ELECTRONICALLY SIGNED.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-07-23 Cont ID  
Sent By rthermid Date 2020-07-23 Time   Rev Time 0.00
Received By rthermid Date 2020-07-23 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-06-05 Cont ID  
Sent By rthermid Date 2020-06-05 Time   Rev Time  
Received By rthermid Date 2020-06-05 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved