Plan Review Details - Permit 20050444
Plan Review Stops For Permit 20050444
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-07-27 Cont ID  
Sent By jwitmer Date 2020-07-27 Time 10:31 Rev Time 0.00
Received By hmoser Date 2020-07-31 Time 11:29 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-05-25 Cont ID  
Sent By jwitmer Date 2020-05-25 Time 16:17 Rev Time 0.00
Received By jwitmer Date 2020-05-25 Time 15:34 Sent To  
Notes
2020-05-25 16:17:07PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-27 Cont ID  
Sent By jwitmer Date 2020-07-27 Time 10:31 Rev Time 0.00
Received By jwitmer Date 2020-07-27 Time 10:16 Sent To  
Notes
2020-07-27 10:25:32DATE: MON. JULY 27TH/ 2020
 ACTION:BUILDING PROVISO
  
 1) SHEET A1 INDICATES THE AIR HANDLER IS TO BE
 REPLACED, NOTE 5 INDICATES DUCT WORK TO REMAIN, THE
 PLANS ARE SILENT AS TO HOW THE RETURN AIR IS GETTING TO
 THE AIR HANDLER.
 IF THE BI-FOLD DOORS ARE USED TO TRANSFER THE RETURN
 AIR TO THE UNIT THEN THE LOUVER DOORS NEED TO BE METAL.
 2017 FBC-B SECTION 2801.1 MECHANICAL EQUIPMENT AND
 SYSTEMS SHALL BE CONSTRUCTED, INSTALLED AND MAINTAINED
 IN ACCORDANCE WITH THE FBC-M AND FBC-B FOR PLENUMS.
 JAMES A. WITMER BN, PX, SFP, CBO

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-05-25 Cont ID  
Sent By jwitmer Date 2020-05-25 Time 16:18 Rev Time 0.00
Received By jwitmer Date 2020-05-25 Time 15:32 Sent To  
Notes
2020-05-25 16:16:152017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050444
 ADD: 37050444
 CONT: WENDELL HALL INC.
 TEL: 561-863-5525
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY, MAY 25TH/2020
 ACTION: DENIED
  
 1) THE COVERSHEET (CVR) HAS THE ADDRESS OF THE WEST
 PALM BEACH BUILDING DIVISION & ZONING DIVISION AT 2300
 N. CONGRESS, PLEASE UPDATE THE PLAN THAT ADDRESS IS FOR
 THE PALM BEACH COUNTY BUILDING & ZONING DEPARTMENTS.
 DISCREPANCY IN PLANS. 107.2.1.2 ADDITIONAL INFORMATION
 REQUIRED.
  
 2) SHEET A1 INDICATES THE AIR HANDLER IS TO BE
 REPLACED, NOTE 7 INDICATES DUCT WORK TO REMAIN, THE
 PLANS ARE SILENT AS TO HOW THE RETURN AIR IS GETTING TO
 THE AIR HANDLER. IS THE BI-FOLD LOUVER DOOR A LOUVER
 DOOR AND THE RETURN AIR GOES THROUGH THE LOUVER? IS THE
 BI-FOLD DOOR A WOOD LOUVER.
 2017 FBC-B SECTION 2801.1 MECHANICAL EQUIPMENT AND
 SYSTEMS SHALL BE CONSTRUCTED, INSTALLED AND MAINTAINED
 IN ACCORDANCE WITH THE FBC-M AND FBC-B FOR PLENUMS.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-07 Cont ID  
Sent By jleahy Date 2020-08-07 Time 16:45 Rev Time 0.00
Received By jleahy Date 2020-08-07 Time 16:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-04 Cont ID  
Sent By jleahy Date 2020-06-04 Time 13:28 Rev Time 0.00
Received By jleahy Date 2020-06-04 Time 13:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-07-23 Cont ID  
Sent By pleduc Date 2020-07-23 Time   Rev Time 0.00
Received By pleduc Date 2020-07-23 Time 13:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-05-21 Cont ID  
Sent By pleduc Date 2020-05-21 Time   Rev Time 0.00
Received By pleduc Date 2020-05-20 Time 10:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-07 Cont ID  
Sent By jleahy Date 2020-08-07 Time 16:46 Rev Time 0.00
Received By jleahy Date 2020-07-22 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-18 Cont ID  
Sent By tklarge Date 2020-06-18 Time 13:55 Rev Time 0.00
Received By tklarge Date 2020-05-19 Time 14:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By hmoser Date 2020-07-31 Time 11:48 Rev Time 0.00
Received By hmoser Date 2020-07-31 Time 11:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-01 Cont ID  
Sent By medwards Date 2020-06-01 Time 10:39 Rev Time 0.00
Received By medwards Date 2020-05-29 Time 13:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-06-18 Cont ID  
Sent By tklarge Date 2020-06-18 Time 13:55 Rev Time 0.00
Received By tklarge Date 2020-06-18 Time 13:52 Sent To  
Notes
2020-06-18 13:55:59PLANS SHOW NO PLUMBING WORK BEING DONE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-07 Cont ID  
Sent By jleahy Date 2020-08-07 Time 16:45 Rev Time 0.00
Received By jleahy Date 2020-08-07 Time 16:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-29 Cont ID  
Sent By medwards Date 2020-05-29 Time 13:38 Rev Time 0.00
Received By medwards Date 2020-05-29 Time 13:37 Sent To  
Notes
***NONE***