Plan Review Details - Permit 20050399
Plan Review Stops For Permit 20050399
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-07-29 Cont ID  
Sent By cpuell Date 2021-07-29 Time 09:15 Rev Time 0.00
Received By cpuell Date 2021-07-29 Time 09:15 Sent To  
Notes
2021-07-29 09:15:42ADD ADDRESSING - HALF ADDRESS VIOLATION

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-07-27 Cont ID  
Sent By lcrespo Date 2020-07-27 Time 14:36 Rev Time 0.00
Received By lcrespo Date 2020-07-27 Time 14:36 Sent To  
Notes
2020-07-27 15:56:4607/27/20 1ST GAS/ REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLANS FOR MASTER 19040482 NEED TO BE UPLOADED TO
 PROJECT DOCS SO A COMPREHENSIVE REVIEW CAN BE
 COMPLETED.
 2. PLEASE PROVIDE SPECS FOR TANKLESS WATER HEATERS PER
 THE 2017 FBC RES. SEC. G2408.1.
 3. THESE TANKLESS UNIT CALL FOR 10.5? WATER COLUMN AND
 THE SERVICE METER DISCHARGES IS A 12? WATER COLUMN
 REQUIRING A REGULATOR FOR THIS UNIT AS PER
 MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER?S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES.
 SEC. G2421.1.
 4. PLEASE LABEL DRIP LEG ON TANKLESS AND SHOW REGULATOR
 WITH UNION ON ISOMETRIC PER THE WPB AMENDMENTS TO THE
 FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 5. THE LOCATION OF TANKLESS ARE SHOWN INSIDE THE HOME
 PLEASE CLARIFY THE TYPE OF VENTING BEING USED AND THE
 EXIT LOCATION TO EXHAUST TO THE OUTSIDE FROM ANY DOOR
 OR OPERABLE WINDOW OF THE TANKLESS WATER HEATER FROM
 EACH VENT AND INTAKE PER THE WPB AMENDMENTS TO THE FBC
 SEC. 107.2.1. INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-27 Cont ID  
Sent By lcrespo Date 2020-07-27 Time 14:37 Rev Time 0.00
Received By lcrespo Date 2020-07-13 Time 11:03 Sent To  
Notes
2020-07-15 11:06:15PLANS UNDER 19040782

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-27 Cont ID  
Sent By lcrespo Date 2020-07-27 Time 14:37 Rev Time 0.00
Received By lcrespo Date 2020-07-27 Time 14:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-07-27 Cont ID  
Sent By lcrespo Date 2020-07-27 Time 14:37 Rev Time 0.00
Received By lcrespo Date 2020-07-27 Time 14:37 Sent To  
Notes
***NONE***