| Plan Review Stops For Permit 20050315 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-09 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-09 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-24 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-24 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-03 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2020-09-14 14:29:41 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 2ND REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | | | 1) PLEASE PROVIDE DETAILS FOR THE METAL FRAMING FRONT | | | CANOPY AND BOX OUTS - SHOW ALL FRAMING DESIGNATIONS AND | | | ATTACHMENTS TO COMPLY WITH THE DESIGN WIND LOADS PER | | | DRAWING S.9 ( PLEASE SHOW ATTACHMENT OF THE FRAMING TO | | | THE CONCRETE STRUCTURE) | | | | | | 2) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | | APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED | | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-52.5) | | | - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT | | | APPROVAL.) | | | | | | 3) PLEASE PROVIDE A DIGITALLY SIGNED AND SEALED SURVEY | | | SHOWING THE FLOOD ZONE PER THE LATEST FIRM . FBC WPB | | | AMENDMENTS 107.2.5 | | | | | | 4) GARAGE FINISHED FLOOR ELEVATIONS BELOW FEMA BASE | | | FLOOD ELEVATION ARE REQUIRED TO HAVE FLOOD VENTS PER | | | FBC R322.2.2 PLEASE PROVIDE THE REQUIRED STATEMENT - (A | | | STATEMENT BY A REGISTERED DESIGN PROFESSIONAL THAT THE | | | DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF | | | HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING | | | FOR THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS | | | SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24.) | | | R322.2.2 ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | | (2.) BE PROVIDED WITH FLOOD OPENINGS THAT MEET THE | | | FOLLOWING CRITERIA AND ARE INSTALLED IN ACCORDANCE WITH | | | SECTION R322.2.2.1: | | | | | | 2.1.THE TOTAL NET AREA OF NON-ENGINEERED OPENINGS SHALL | | | BE NOT LESS THAN 1 SQUARE INCH (645 MM2) FOR EACH | | | SQUARE FOOT (0.093 M2) OF ENCLOSED AREA WHERE THE | | | ENCLOSED AREA IS MEASURED ON THE EXTERIOR OF THE | | | ENCLOSURE WALLS, OR THE OPENINGS SHALL BE DESIGNED AS | | | ENGINEERED OPENINGS AND THE CONSTRUCTION DOCUMENTS | | | SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN | | | PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL | | | PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON | | | EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND | | | EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF | | | ASCE 24. | | | | | | 2.2.OPENINGS SHALL BE NOT LESS THAN 3 INCHES (76 MM) IN | | | ANY DIRECTION IN THE PLANE OF THE WALL. | | | | | | 2.3.THE PRESENCE OF LOUVERS, BLADES, SCREENS AND | | | FACEPLATES OR OTHER COVERS AND DEVICES SHALL ALLOW THE | | | AUTOMATIC FLOW OF FLOODWATER INTO AND OUT OF THE | | | ENCLOSED AREAS AND SHALL BE ACCOUNTED FOR IN THE | | | DETERMINATION OF THE NET OPEN AREA. | | | | | | 5) EQUIPMENT SHOWN IN THE GARAGE AND OUTSIDE THE | | | BUILDING (WASHER, DRYER, AC ETC.) WILL NEED TO BE | | | ELEVATED TO COMPLY WITH FBC R322.1.6 | | | | | | 6) PLEASE SHOW THE REQUIRED RAILING AT THE 2ND FLOOR | | | "OPENING TO BELOW". FBC R312 | | | | | | 7) PLEASE PROVIDE A COMPLETED ELEVATION CERTIFICATE - | | | MARKED ( CONSTRUCTION DRAWINGS). FBC WPB AMENDMENTS | | | 107.3.5.1.1 (1) | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-02 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-02 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2020-06-02 15:50:50 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE REQUIRED DRAFT STOPPING FOR THE | | | CEILING / FLOOR ASSEMBLY TO COMPLY WITH FBC R302.12 | | | 2) PLEASE SHOW THE REQUIRED HANDRAILS FOR ALL STAIRS | | | (GARAGE TO LIVING SPACE) (FRONT ENTRY) TO COMPLY WITH | | | FBC R311.7.8 (R311.3.1) | | | 3) PLEASE SHOW THE WIDTH OF THE STAIRS IN GARAGE NUMBER | | | 1 TO COMPLY WITH FBC R311.7.1 | | | 4) BEDROOM NUMBER 3 DOES NOT COMPLY WITH EMERGENCY | | | EGRESS REQUIREMENTS PER FBC R310.2.1 | | | 5) PLEASE SHOW THE REQUIRED LENGTH OF THE LEDGER ANCHOR | | | BOLTS FOR NOTE NUMBER 8 ON DRAWING (S.5) | | | 6) DRAWING S.9 SHOWS WIND DESIGN PER ASCE 7-16 = SHOULD | | | BE ASCE 7-10 PER FBC CHAPTER 35. | | | 7) PLEASE PROVIDE DETAILS FOR THE METAL FRAMING FRONT | | | CANOPY AND BOX OUTS - SHOW ALL FRAMING DESIGNATIONS AND | | | ATTACHMENTS TO COMPLY WITH THE DESIGN WIND LOADS PER | | | DRAWING S.9 | | | 8) PLEASE PROVIDE COMPLETE PRODUCT APPROVALS FOR THE | | | OVERHEAD GARAGE DOOR AND (SS-3500 IMPACT - RESISTANT | | | STOREFRONT WINDOW SYSTEM) - NEED FRONT PAGES FOR THE | | | MIAMI DADE OR FLORIDA STATE PRODUCT APPROVALS - ONLY | | | THE INSTALLATION INSTRUCTIONS WERE PROVIDED. | | | 9) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD. | | | 10) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE ROOFING SYSTEM TO BE USED. | | | 11) PRIVACY WALL SHALL BE ON A SEPARATE PERMIT - PLEASE | | | MAKE NOTE ON THE DRAWING. | | | 12) PLEASE PROVIDE A DIGITALLY SIGNED AND SEALED SURVEY | | | SHOWING THE FLOOD ZONE PER THE LATEST FIRM AND THE | | | PROPERTY DRAINAGE. | | | 13) PALM BEACH COUNTY FLOOD MAPS SHOW THIS PROPERTY IN | | | A FLOOD ZONE (AE 7) - PLEASE SHOW THE FINISHED FLOOR | | | ELEVATION 2 FEET ABOVE THE BASE FLOOD ELEVATION (FFE = | | | 9.00 NAVD) OR HIGHER. FBC R322.2.1 | | | 14) GARAGE FINISHED FLOOR ELEVATIONS BELOW FEMA BASE | | | FLOOD ELEVATION ARE REQUIRED TO HAVE FLOOD VENTS PER | | | FBC R322.2.2 | | | 15) EQUIPMENT SHOWN IN THE GARAGE AND OUTSIDE THE | | | BUILDING (WASHER, DRYER, AC ETC.) WILL NEED TO BE | | | ELEVATED TO COMPLY WITH FBC R322.1.6 | | | 16) DRAWINGS SHOW "ICYNENE" INSULATION TO THE BOTTOM OF | | | THE ROOF DECK AND VENTED ATTIC SPACE. SHOULD THE ATTIC | | | BE VENTED? | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-18 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-17 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-11 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-11 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-04 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-03 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2020-06-04 09:54:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-1 AND E-2 | | | | | | 1) PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 NOT | | | ALL LOCATED WITHIN 10' OF THE SLEEPING AREAS. | | | | | | PAGE E=3 | | | | | | 2) PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT | | | CURRENT AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. | | | NEC 110.10 | | | | | | 3) PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE3602.3 | | | | | | 4) GROUND ROD AT PANELS ??? | | | | | | 5) PANEL SCHEDULE SHALL BE LEGIBLY IDENTIFIED AS TO | | | THEIR CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE | | | IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW | | | EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE | | | POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR | | | SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE | | | IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY | | | LOCATED ON THE FACE OF THE PANELBOARD ENCLOSURE OR | | | INSIDE THE PANEL DOOR. CIRCUITS SHALL NOT BE DESCRIBED | | | IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF | | | OCCUPANCY. FBC RE3706. OUTLETS AND LIGHTS NOT | | | ACCEPTABLE. | | | | | | 6) NOTE #5 CALLS FOR EMT UNDERGROUND, EMT NOT ALLOWED | | | IN THE EARTH WITHOUT A CORROSION INHIBITOR. 358.10(B) | | | CORROSION PROTECTION. FERROUS OR NONFERROUS EMT, | | | ELBOWS, COUPLINGS, AND FITTINGS SHALL BE PERMIT TED TO | | | BE INSTALLED IN CONCRETE, IN DIRECT CONTACT WITH THE | | | EARTH, OR IN AREAS SUBJECT TO SEVERE CORROSIVE | | | INFLUENCES WHERE PROTECTED BY CORROSION PROTECTION AND | | | APPROVED AS SUITABLE FOR THE CONDITION. | | | | | | PAGE E-1 | | | | | | 7) PROVIDE AN OUTLET (GFCI) WITH 6' AND NOT MORE THAN | | | 20' FROM POOL. E4203.1.2 WHERE REQUIRED. AT LEAST ONE | | | 125-VOLT, 15- OR 20-AMPERE RECEPTACLE SUPPLIED BY A | | | GENERAL-PURPOSE BRANCH CIRCUIT SHALL BE LOCATED A | | | MINIMUM OF 6 FEET (1829 MM) FROM AND NOT MORE THAN 20 | | | FEET (6096 MM) FROM THE INSIDE WALL OF POOLS AND | | | OUTDOOR SPAS AND HOT TUBS. THIS RECEPTACLE SHALL BE | | | LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE | | | THE FLOOR, PLATFORM OR GRADE LEVEL SERVING THE POOL, | | | SPA OR HOT TUB. [680.22(A)(1)] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-07 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-07 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-02 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-02 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-09-02 13:39:40 | 09/02/20 2 ND GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE NOTE THAT IF A GAS REVIEW IS DONE IT MUST BE | | | COMPLETED AND A SEPARATE GAS SUB PERMIT WILL BE ISSUED | | | BUT ALL COMMENTS AND CONCERNS HAVE TO BE ADDRESSED BY | | | REGISTERED ARCHITECT. | | | | | | 2. SIGNED AND SEALED DRAWINGS NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - | | | IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR DIGITAL | | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | | ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN | | | REVIEW REQUEST FORM" EXPLAINING THE REASON FOR | | | SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | | AND ASKING FOR THE FORM. | | | | | | 3. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS-STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. ON PLANS IT SAYS FIRE PLACE, FIRE BAR AND FIRE PIT, | | | THERE IS ONLY ONE SPECIFICATION SUBMITTED AND IS IT A | | | FIRE PLACE, ARE THE TWO FIRE PLACES IN THE HOUSE THE | | | SAME AND IF NOT PLEASE SUBMIT OR RELABEL ON ISOMETRIC | | | FOR CLARITY ON PLANS PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. SHEET A-1 SHOW ELECTRIC WATER HEATER, PLEASE REMOVE | | | AND SHOW GAS TYPE PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 6. SHEET 023 P-5 IS LABELED AS ISOMETRIC GAS RISER | | | WHICH HAS NO DETAIL ABOUT GAS AND 035 P-8 HAS THE | | | ISOMETRIC INFORMATION PLEASE SWAP AND SHOW. P-5 HAS A | | | STORAGE TANK WATER HEATER PLEASE CHANGE AND DELETE | | | INFORMATION NOT PERTAINING TO PLANS PER THE WPB | | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 7. THE TANK-LEES HEATER SPECIFICATION HAS 160 BTU'S BUT | | | THE ISOMETRIC HAS 300 BTU'S PLEASE RECALCULATE AND | | | DOUBLE CHECK ALL BTU'S TO COORDINATE WITH ISOMETRIC | | | TOTAL BTU'S PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. THE TANK-LESS GAS HEATER HAS A CONDENSATE LINE THAT | | | DRIP CONSTANTLY PLEASE MAKE A NOTE THAT THAT SHALL BE | | | 1' AWAY FROM BUILDING PER THE 2017 FBC SEC G318.5. | | | | | | 9. PLEASE LIST THE BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2017 | | | FBC-RES. SEC. G2413.3, G2413.4 AND TABLES G2413.4 (1 ) | | | THROUGH G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES | | | ARE USED. | | | | | | 10. THESE TANK-LESS UNIT CALL FOR 10.5" WATER COLUMN | | | WHICH REQUIRING A REGULATOR FOR THIS UNIT AS PER | | | MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | | APPROVED FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES. | | | SEC. G2421.1. | | | | | | 11. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1' OF | | | EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2. | | | | | | 12. SHOW DRIP LEG ON EQUIPMENT INSTALLED EXCEPT FOR | | | APPLIANCES, RANGE, DRYERS & OD GRILLS PER THE 2017 FBC | | | RES. SEC. G2419.2. | | | | | | 13. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC FG SEC. 304.1, 614.5 (CLOTHES DRYERS COOK TOP AND | | | OVEN) OR 2017 FBC RES. SEC. G2407.1 AND G2439.4. | | | | | | 14. IF USING LOVERS, PLEASE SHOW THE LOCATION OF THE | | | METAL OR WOOD LOUVERS THAT ARE BEING INSTALLED FOR THE | | | COMBUSTION AIR. THE LOUVERS CANNOT BE LOCATED ON AN | | | EXTERIOR WALL THAT IS FIRE RATED AS THE FIRE RATING OF | | | THE WALL MUST BE MAINTAINED PER THE WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 15. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC RES. SEC. G2413.2. | | | | | | 16. SUBMIT MANUFACTURER?S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT (FIRE | | | PIT, FIRE BAR/OUTDOOR GRILL, COOK TOP AND DRYER) TO | | | VERIFY COMPLIANCE, WITH STANDARDS NFPA 54, NFPA 58, AND | | | 2017 FBC-RES. SEC. G2404.3. | | | | | | 17. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FBC-RES. | | | SEC. G2408.1. | | | | | | 18. THE ISOMETRIC SHOWS A GAS GRILL PLEASE INDICATE ON | | | THE PLAN IF THE GRILL IS LOCATED UNDER A ROOF AND IF IN | | | A COVERED PATIO, PLEASE PROVIDE MANUFACTURES | | | RECOMMENDATION FOR A VENTILATION HOOD PER THE 2017 FBC | | | RES. SEC. G2408.1. | | | | | | 19. SUBMIT ON A HOUSE PLAN SHOWING THE LOCATION OF THE | | | TANK-LESS WATER HEATER AND THE LOCATION AND DISTANCE OF | | | ANY OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER | | | HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY | | | WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER | | | THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 20. THESE IS A FIRE PIT SHOW ON ISOMETRIC BUT NOT ON | | | FLAT PLAN PLEASE SHOW LOCATION PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-06-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-08 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-08 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2020-06-08 15:31:05 | PLAN REVIEW ? FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT TWO COPIES OF AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE | | | PER 2017 FBC-R SEC. G2413.4.1, G2413.4.2. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING | | | | | | (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-RES. SEC. | | | G2413.3, G2413.4 AND TABLES G2413.4 (1 ) THROUGH | | | G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES ARE | | | USED. | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-RES. SEC. G 2413.4.1, G2413.4.2. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES DRYERS). | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 8. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC-RES. SEC.G2426 THROUGH G2439. | | | | | | 9. SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FBC-RES. SEC.G2408.1. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-03 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-03 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-18 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-18 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-09 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-29 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-08 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-07 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-09-25 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-09-01 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-15 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-02 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-08-18 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2021-08-31 14:35:10 | RECEIPT MU-2021-041888 - $9948.86 PAID | | 2021-08-18 14:01:46 | 8/18/2021 EMAILED IMPACT FOR REVIEW-AO | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-02 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-02 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2020-06-02 16:00:46 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-14 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-14 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-02-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-09 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-09 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-05-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-05-27 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-05-27 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-05-27 15:34:02 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT -20020315 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 1) PLEASE SHOW A DETAIL DRAWING OF AHU AND THE DUCT | | | WORK IN THE GARAGE. FBC RES R302.5.2 | | | | | | 2) SHOW A DETAIL DRAWING OF THE DRYER DUCTWORK IN THE | | | GARAGE AT THE RATED WALL. FBC RES R302.5.3 | | | | | | 3) PLEASE PROVIDE THE MODEL NUMBERS FOR THE RANGE AND | | | THE HOOD. FBC FS 107.2.1 | | | | | | 4) PROVIDE THE CFM?S OF THE HOOD, ALSO MAKEUP AIR. FBC | | | FS 107.2.1 | | | | | | 5) IS THE FIREPLACE UNVENTED? PLEASE PROVIDE THE MODEL | | | NUMBER FOR THE FIREPLACE. FBC FS 107.2.1 | | | | | | 6) PLEASE SHOW VENTING FOR THE FIREPLACE IN THE MASTER | | | BEDROOM. FBC FS 107.2.1 | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-24 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2021-05-24 14:16:03 | FIRM = AE 7 | | | PROPOSED FINISHED FLOOR = 10.68 NAVD | | | GARAGE = 7.68 NAVD - SHOWS PROPOSED FLOOD VENTS | | | AC PAD = 9.18 NAVD |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-14 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2020-09-14 14:31:38 | SEE BUILDING PLAN REVIEW. | | | FLOOD ZONE (AE 7) | | | FFE = 9.18 | | | GARAGE FLOOD VENTS = | | | EQUIPMENT ELEVATION = |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-02 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-02 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2020-06-02 16:02:13 | SEE BUILDING PLAN REVIEW. | | | FLOOD ZONE (AE 7) | | | FFE = | | | GARAGE FLOOD VENTS = | | | EQUIPMENT ELEVATION = |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-07 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-07 |
Time |
18:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-02 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-02 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-09-02 14:12:51 | 09/02/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE SHOW THE DISTANCE BETWEEN THE SHOWER, WATER | | | CLOSET AND BIDET TO BE 30" BETWEEN FIXTURES PER THE | | | 2017 FBC SEC. R 2705.1 GENERAL. | | | | | | 2. BIDET SHALL HAVE A WATER TEMPERATURE NOT GREATER | | | THAN 110 F BY A WATER-TEMPERATURE-LIMITING DEVICE | | | CONFORMING TO ASSE 1070 OR CSA B125.3 PER THE 2017 FBC | | | SEC. R 2721.2 BIDET WATER TEMPERATURE. | | | | | | 3. ROMAN TUB HOT WATER SUPPLIED SHALL BE LIMITED TO A | | | TEMPERATURE OF NOT GREATER THAN 120 F BY A WATER | | | TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070 | | | OR CSA B125.3, EXCEPT WHERE SUCH PROTECTION IS | | | OTHERWISE PROVIDED BY A COMBINATION TUB/SHOWER VALVE IN | | | ACCORDANCE WITH SECTION P2708.4. IF TEMPERING VALVE IS | | | INSTALLED IT SHALL HAVE AN ACCESS TO IT. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-08 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-08 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2020-06-08 15:29:58 | PLAN REVIEW - PLUMBING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SHOWER PAN DETAIL. | | | P2709.1 SHOWER PAN CONSTRUCTION. FBC 107.2.1 | | | | | | 2. LABEL ALL PIPE SIZES ON SANITARY RISER. | | | P3005.4DRAIN PIPE SIZING. | | | | | | 3. PROVIDE WATER DISTRIBUTION RISER DIAGRAHM. | | | P2903.1WATER SUPPLY SYSTEM DESIGN CRITERIA.THE WATER | | | SERVICE AND WATER DISTRIBUTION SYSTEMS SHALL BE | | | DESIGNED, AND PIPE SIZES SHALL BE SELECTED SUCH THAT | | | UNDER CONDITIONS OF PEAK DEMAND, THE CAPACITIES AT THE | | | POINT OF OUTLET DISCHARGE SHALL NOT BE LESS THAN SHOWN | | | IN TABLE P2903.1. | | | | | | 4. PROVIDE THERMOSTATIC SHOWER CONTROL VALVES. | | | P2708.4SHOWER CONTROL VALVES. INDIVIDUAL SHOWER AND | | | TUB/ SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH | | | CONTROL VALVES OF THE PRESSURE-BALANCE, | | | THERMOSTATIC-MIXING OR COMBINATION | | | PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A | | | HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME | | | A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET | | | TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN | | | 120?F (49?C). IN-LINE THERMOSTATIC VALVES SHALL NOT BE | | | USED FOR COMPLIANCE WITH THIS SECTION. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-18 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-18 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-09 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-09 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2021-08-09 10:06:54 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | | | 1) DRAWING A-4 SHOWS A TAPERED INSULATED ROOF. THE | | | PROVIDED PRODUCT APPROVAL ROOFING SYSTEM IS FOR A NON | | | INSULATED ROOF SYSTEM. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-24 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-24 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2021-05-24 14:09:35 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | | | 1) 2ND REVISION OF THE ROOFING PRODUCT APPROVAL | | | PROVIDED DOES NOT SHOW A ROOFING SYSTEM TO BE USED - | | | PLEASE CIRCLE A ROOFING SYSTEM TO BE USED ON THE | | | PRODUCT APPROVAL - STARTING ON PAGE 8 OF THE PRODUCT | | | APPROVAL. ROOFING SYSTEM TO BE USED ON THE PROVIDED | | | PRODUCT APPROVAL MAY REQUIRE ADDITIONAL SIGNED AND | | | SEALED ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER | | | FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER | | | PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL | | | ( ) - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE | | | PRODUCT APPROVAL.) | | | | | | 2) ROOFING SYSTEMS PRODUCT APPROVALS MAY BE DEFERRED | | | SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON THE | | | CONSTRUCTION DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-14 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-09-14 14:32:24 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-02 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-02 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2020-06-02 16:04:38 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-03 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-03 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-18 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-18 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2021-08-18 15:46:10 | SIGNATURE REVIEW | | | DOCUMENT LABELED "ROOF ENGINEERING.PDF" IN PROJECTDOX | | | DOES NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE READER | | | - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR - | | | IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-07 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-07 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2021-05-07 15:00:56 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-14 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-09-14 14:33:07 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | | AND ASKING FOR THE FORM. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-02 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2020-06-02 16:07:17 | ALL SIGNED AND SEALED DRAWINGS NEED TO BE DIGITALLY OR | | | ELECTRONICALLY SIGNED BY THE ARCHITECT OR ENGINEER FOR | | | USE IN PROJECTDOX. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-05-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-05-25 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-05-25 10:09:37 | SEPERATE PERMITS NEEDED FOR DRIVEWAY, POOLS, MECHANICAL | | | EQUIPMENT AND ANY ADDITIONAL WORK ONSITE. | | | | | | RAFAELA THERMIDOR | | | 561-822-1443 - [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-09-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-05-27 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-05-27 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-05-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-05-27 09:30:47 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 5/27/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY AS IT | | | APPEARS PART OF THE POOL IS IN AN EASEMENT AND EXCEEDS | | | THE 75% OR 1000 SQUARE FEET REQUIREMENT | | | 2. INDICATE THE SETBACK DIMENSIONS FROM PROPOSED POOL | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO THE CITY | | | OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR) SECTION 94-305(B)(4): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1443 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG |
|
|