Plan Review Details - Permit 20050315
Plan Review Stops For Permit 20050315
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 10:04 Rev Time 0.00
Received By rmcphers Date 2021-08-09 Time 10:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 13:58 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 13:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-09-14 Cont ID  
Sent By rmcphers Date 2020-09-14 Time 14:29 Rev Time 0.00
Received By rmcphers Date 2020-09-03 Time 15:08 Sent To  
Notes
2020-09-14 14:29:41NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 2ND REVIEW
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) PLEASE PROVIDE DETAILS FOR THE METAL FRAMING FRONT
 CANOPY AND BOX OUTS - SHOW ALL FRAMING DESIGNATIONS AND
 ATTACHMENTS TO COMPLY WITH THE DESIGN WIND LOADS PER
 DRAWING S.9 ( PLEASE SHOW ATTACHMENT OF THE FRAMING TO
 THE CONCRETE STRUCTURE)
  
 2) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-52.5)
 - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL.)
  
 3) PLEASE PROVIDE A DIGITALLY SIGNED AND SEALED SURVEY
 SHOWING THE FLOOD ZONE PER THE LATEST FIRM . FBC WPB
 AMENDMENTS 107.2.5
  
 4) GARAGE FINISHED FLOOR ELEVATIONS BELOW FEMA BASE
 FLOOD ELEVATION ARE REQUIRED TO HAVE FLOOD VENTS PER
 FBC R322.2.2 PLEASE PROVIDE THE REQUIRED STATEMENT - (A
 STATEMENT BY A REGISTERED DESIGN PROFESSIONAL THAT THE
 DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF
 HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING
 FOR THE AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS
 SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24.)
 R322.2.2 ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION.
 (2.) BE PROVIDED WITH FLOOD OPENINGS THAT MEET THE
 FOLLOWING CRITERIA AND ARE INSTALLED IN ACCORDANCE WITH
 SECTION R322.2.2.1:
  
 2.1.THE TOTAL NET AREA OF NON-ENGINEERED OPENINGS SHALL
 BE NOT LESS THAN 1 SQUARE INCH (645 MM2) FOR EACH
 SQUARE FOOT (0.093 M2) OF ENCLOSED AREA WHERE THE
 ENCLOSED AREA IS MEASURED ON THE EXTERIOR OF THE
 ENCLOSURE WALLS, OR THE OPENINGS SHALL BE DESIGNED AS
 ENGINEERED OPENINGS AND THE CONSTRUCTION DOCUMENTS
 SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN
 PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL
 PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON
 EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND
 EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF
 ASCE 24.
  
 2.2.OPENINGS SHALL BE NOT LESS THAN 3 INCHES (76 MM) IN
 ANY DIRECTION IN THE PLANE OF THE WALL.
  
 2.3.THE PRESENCE OF LOUVERS, BLADES, SCREENS AND
 FACEPLATES OR OTHER COVERS AND DEVICES SHALL ALLOW THE
 AUTOMATIC FLOW OF FLOODWATER INTO AND OUT OF THE
 ENCLOSED AREAS AND SHALL BE ACCOUNTED FOR IN THE
 DETERMINATION OF THE NET OPEN AREA.
  
 5) EQUIPMENT SHOWN IN THE GARAGE AND OUTSIDE THE
 BUILDING (WASHER, DRYER, AC ETC.) WILL NEED TO BE
 ELEVATED TO COMPLY WITH FBC R322.1.6
  
 6) PLEASE SHOW THE REQUIRED RAILING AT THE 2ND FLOOR
 "OPENING TO BELOW". FBC R312
  
 7) PLEASE PROVIDE A COMPLETED ELEVATION CERTIFICATE -
 MARKED ( CONSTRUCTION DRAWINGS). FBC WPB AMENDMENTS
 107.3.5.1.1 (1)
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By rmcphers Date 2020-06-02 Time 15:59 Rev Time 0.00
Received By rmcphers Date 2020-06-02 Time 09:18 Sent To  
Notes
2020-06-02 15:50:50NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE REQUIRED DRAFT STOPPING FOR THE
 CEILING / FLOOR ASSEMBLY TO COMPLY WITH FBC R302.12
 2) PLEASE SHOW THE REQUIRED HANDRAILS FOR ALL STAIRS
 (GARAGE TO LIVING SPACE) (FRONT ENTRY) TO COMPLY WITH
 FBC R311.7.8 (R311.3.1)
 3) PLEASE SHOW THE WIDTH OF THE STAIRS IN GARAGE NUMBER
 1 TO COMPLY WITH FBC R311.7.1
 4) BEDROOM NUMBER 3 DOES NOT COMPLY WITH EMERGENCY
 EGRESS REQUIREMENTS PER FBC R310.2.1
 5) PLEASE SHOW THE REQUIRED LENGTH OF THE LEDGER ANCHOR
 BOLTS FOR NOTE NUMBER 8 ON DRAWING (S.5)
 6) DRAWING S.9 SHOWS WIND DESIGN PER ASCE 7-16 = SHOULD
 BE ASCE 7-10 PER FBC CHAPTER 35.
 7) PLEASE PROVIDE DETAILS FOR THE METAL FRAMING FRONT
 CANOPY AND BOX OUTS - SHOW ALL FRAMING DESIGNATIONS AND
 ATTACHMENTS TO COMPLY WITH THE DESIGN WIND LOADS PER
 DRAWING S.9
 8) PLEASE PROVIDE COMPLETE PRODUCT APPROVALS FOR THE
 OVERHEAD GARAGE DOOR AND (SS-3500 IMPACT - RESISTANT
 STOREFRONT WINDOW SYSTEM) - NEED FRONT PAGES FOR THE
 MIAMI DADE OR FLORIDA STATE PRODUCT APPROVALS - ONLY
 THE INSTALLATION INSTRUCTIONS WERE PROVIDED.
 9) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD.
 10) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE ROOFING SYSTEM TO BE USED.
 11) PRIVACY WALL SHALL BE ON A SEPARATE PERMIT - PLEASE
 MAKE NOTE ON THE DRAWING.
 12) PLEASE PROVIDE A DIGITALLY SIGNED AND SEALED SURVEY
 SHOWING THE FLOOD ZONE PER THE LATEST FIRM AND THE
 PROPERTY DRAINAGE.
 13) PALM BEACH COUNTY FLOOD MAPS SHOW THIS PROPERTY IN
 A FLOOD ZONE (AE 7) - PLEASE SHOW THE FINISHED FLOOR
 ELEVATION 2 FEET ABOVE THE BASE FLOOD ELEVATION (FFE =
 9.00 NAVD) OR HIGHER. FBC R322.2.1
 14) GARAGE FINISHED FLOOR ELEVATIONS BELOW FEMA BASE
 FLOOD ELEVATION ARE REQUIRED TO HAVE FLOOD VENTS PER
 FBC R322.2.2
 15) EQUIPMENT SHOWN IN THE GARAGE AND OUTSIDE THE
 BUILDING (WASHER, DRYER, AC ETC.) WILL NEED TO BE
 ELEVATED TO COMPLY WITH FBC R322.1.6
 16) DRAWINGS SHOW "ICYNENE" INSULATION TO THE BOTTOM OF
 THE ROOF DECK AND VENTED ATTIC SPACE. SHOULD THE ATTIC
 BE VENTED?
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-05-18 Cont ID  
Sent By jleahy Date 2021-05-18 Time 13:16 Rev Time 0.00
Received By jleahy Date 2021-05-17 Time 17:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-09-11 Cont ID  
Sent By jleahy Date 2020-09-11 Time 14:14 Rev Time 0.00
Received By jleahy Date 2020-09-11 Time 13:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-04 Cont ID  
Sent By jleahy Date 2020-06-04 Time 09:54 Rev Time 0.00
Received By jleahy Date 2020-06-03 Time 11:47 Sent To  
Notes
2020-06-04 09:54:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E-1 AND E-2
  
 1) PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 NOT
 ALL LOCATED WITHIN 10' OF THE SLEEPING AREAS.
  
 PAGE E=3
  
 2) PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT
 CURRENT AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE.
 NEC 110.10
  
 3) PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220; FBC RE3602.3
  
 4) GROUND ROD AT PANELS ???
  
 5) PANEL SCHEDULE SHALL BE LEGIBLY IDENTIFIED AS TO
 THEIR CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE
 IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW
 EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE
 POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR
 SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE
 IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY
 LOCATED ON THE FACE OF THE PANELBOARD ENCLOSURE OR
 INSIDE THE PANEL DOOR. CIRCUITS SHALL NOT BE DESCRIBED
 IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF
 OCCUPANCY. FBC RE3706. OUTLETS AND LIGHTS NOT
 ACCEPTABLE.
  
 6) NOTE #5 CALLS FOR EMT UNDERGROUND, EMT NOT ALLOWED
 IN THE EARTH WITHOUT A CORROSION INHIBITOR. 358.10(B)
 CORROSION PROTECTION. FERROUS OR NONFERROUS EMT,
 ELBOWS, COUPLINGS, AND FITTINGS SHALL BE PERMIT TED TO
 BE INSTALLED IN CONCRETE, IN DIRECT CONTACT WITH THE
 EARTH, OR IN AREAS SUBJECT TO SEVERE CORROSIVE
 INFLUENCES WHERE PROTECTED BY CORROSION PROTECTION AND
 APPROVED AS SUITABLE FOR THE CONDITION.
  
 PAGE E-1
  
 7) PROVIDE AN OUTLET (GFCI) WITH 6' AND NOT MORE THAN
 20' FROM POOL. E4203.1.2 WHERE REQUIRED. AT LEAST ONE
 125-VOLT, 15- OR 20-AMPERE RECEPTACLE SUPPLIED BY A
 GENERAL-PURPOSE BRANCH CIRCUIT SHALL BE LOCATED A
 MINIMUM OF 6 FEET (1829 MM) FROM AND NOT MORE THAN 20
 FEET (6096 MM) FROM THE INSIDE WALL OF POOLS AND
 OUTDOOR SPAS AND HOT TUBS. THIS RECEPTACLE SHALL BE
 LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE
 THE FLOOR, PLATFORM OR GRADE LEVEL SERVING THE POOL,
 SPA OR HOT TUB. [680.22(A)(1)]

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2021-06-07 Cont ID  
Sent By abelisle Date 2021-06-07 Time 18:57 Rev Time 0.00
Received By abelisle Date 2021-06-07 Time 18:00 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2020-09-02 Cont ID  
Sent By lcrespo Date 2020-09-02 Time 15:58 Rev Time 0.00
Received By lcrespo Date 2020-09-02 Time 10:41 Sent To  
Notes
2020-09-02 13:39:4009/02/20 2 ND GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE NOTE THAT IF A GAS REVIEW IS DONE IT MUST BE
 COMPLETED AND A SEPARATE GAS SUB PERMIT WILL BE ISSUED
 BUT ALL COMMENTS AND CONCERNS HAVE TO BE ADDRESSED BY
 REGISTERED ARCHITECT.
  
 2. SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE A ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN
 REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.
  
 3. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS-STEEL TUBING (IF APPLICABLE) FOR
 EACH PIPE SIZE PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. ON PLANS IT SAYS FIRE PLACE, FIRE BAR AND FIRE PIT,
 THERE IS ONLY ONE SPECIFICATION SUBMITTED AND IS IT A
 FIRE PLACE, ARE THE TWO FIRE PLACES IN THE HOUSE THE
 SAME AND IF NOT PLEASE SUBMIT OR RELABEL ON ISOMETRIC
 FOR CLARITY ON PLANS PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 5. SHEET A-1 SHOW ELECTRIC WATER HEATER, PLEASE REMOVE
 AND SHOW GAS TYPE PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 6. SHEET 023 P-5 IS LABELED AS ISOMETRIC GAS RISER
 WHICH HAS NO DETAIL ABOUT GAS AND 035 P-8 HAS THE
 ISOMETRIC INFORMATION PLEASE SWAP AND SHOW. P-5 HAS A
 STORAGE TANK WATER HEATER PLEASE CHANGE AND DELETE
 INFORMATION NOT PERTAINING TO PLANS PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 7. THE TANK-LEES HEATER SPECIFICATION HAS 160 BTU'S BUT
 THE ISOMETRIC HAS 300 BTU'S PLEASE RECALCULATE AND
 DOUBLE CHECK ALL BTU'S TO COORDINATE WITH ISOMETRIC
 TOTAL BTU'S PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 8. THE TANK-LESS GAS HEATER HAS A CONDENSATE LINE THAT
 DRIP CONSTANTLY PLEASE MAKE A NOTE THAT THAT SHALL BE
 1' AWAY FROM BUILDING PER THE 2017 FBC SEC G318.5.
  
 9. PLEASE LIST THE BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2017
 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES G2413.4 (1 )
 THROUGH G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES
 ARE USED.
  
 10. THESE TANK-LESS UNIT CALL FOR 10.5" WATER COLUMN
 WHICH REQUIRING A REGULATOR FOR THIS UNIT AS PER
 MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES.
 SEC. G2421.1.
  
 11. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1' OF
 EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2.
  
 12. SHOW DRIP LEG ON EQUIPMENT INSTALLED EXCEPT FOR
 APPLIANCES, RANGE, DRYERS & OD GRILLS PER THE 2017 FBC
 RES. SEC. G2419.2.
  
 13. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017
 FBC FG SEC. 304.1, 614.5 (CLOTHES DRYERS COOK TOP AND
 OVEN) OR 2017 FBC RES. SEC. G2407.1 AND G2439.4.
  
 14. IF USING LOVERS, PLEASE SHOW THE LOCATION OF THE
 METAL OR WOOD LOUVERS THAT ARE BEING INSTALLED FOR THE
 COMBUSTION AIR. THE LOUVERS CANNOT BE LOCATED ON AN
 EXTERIOR WALL THAT IS FIRE RATED AS THE FIRE RATING OF
 THE WALL MUST BE MAINTAINED PER THE WPB AMENDMENTS TO
 FBC SEC.107.2.1.
  
 15. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER 2017 FBC RES. SEC. G2413.2.
  
 16. SUBMIT MANUFACTURER?S SPECIFICATION
 SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT (FIRE
 PIT, FIRE BAR/OUTDOOR GRILL, COOK TOP AND DRYER) TO
 VERIFY COMPLIANCE, WITH STANDARDS NFPA 54, NFPA 58, AND
 2017 FBC-RES. SEC. G2404.3.
  
 17. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION. FBC-RES.
 SEC. G2408.1.
  
 18. THE ISOMETRIC SHOWS A GAS GRILL PLEASE INDICATE ON
 THE PLAN IF THE GRILL IS LOCATED UNDER A ROOF AND IF IN
 A COVERED PATIO, PLEASE PROVIDE MANUFACTURES
 RECOMMENDATION FOR A VENTILATION HOOD PER THE 2017 FBC
 RES. SEC. G2408.1.
  
 19. SUBMIT ON A HOUSE PLAN SHOWING THE LOCATION OF THE
 TANK-LESS WATER HEATER AND THE LOCATION AND DISTANCE OF
 ANY OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER
 HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY
 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER
 THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION
 ON CONSTRUCTION DOCUMENTS.
  
 20. THESE IS A FIRE PIT SHOW ON ISOMETRIC BUT NOT ON
 FLAT PLAN PLEASE SHOW LOCATION PER THE WPB AMENDMENTS
 TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-06-08 Cont ID  
Sent By cthroop Date 2020-06-08 Time 15:30 Rev Time 0.00
Received By cthroop Date 2020-06-08 Time 13:43 Sent To  
Notes
2020-06-08 15:31:05PLAN REVIEW ? FUEL GAS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL
 BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING
 IN THE CITY OF WEST PALM BEACH:
  
 1. SUBMIT TWO COPIES OF AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE
 PER 2017 FBC-R SEC. G2413.4.1, G2413.4.2.
  
 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS STEEL TUBING
  
 (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO
 FBC SEC.107.2.1.
  
 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC.
 107.2.1.
  
 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL
 BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-RES. SEC.
 G2413.3, G2413.4 AND TABLES G2413.4 (1 ) THROUGH
 G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES ARE
 USED.
  
 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017
 FBC-RES. SEC. G 2413.4.1, G2413.4.2.
  
 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017
 FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES DRYERS).
  
 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER 2017 FBC RES. SEC. G2413.2, G2413.4.3.
  
 8. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF
 VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE
 THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER
 2017 FBC-RES. SEC.G2426 THROUGH G2439.
  
 9. SUBMIT TWO COPIES OF THE MANUFACTURER?S
 SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54,
 NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND
 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES
 SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS
 FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT
 THE TIME OF INSPECTION. FBC-RES. SEC.G2408.1.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-09-03 Cont ID  
Sent By cthroop Date 2021-09-03 Time 16:32 Rev Time 0.00
Received By cthroop Date 2021-09-03 Time 14:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-08-18 Cont ID  
Sent By rmcphers Date 2021-08-18 Time 15:46 Rev Time 0.00
Received By rmcphers Date 2021-08-18 Time 13:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 10:07 Rev Time 0.00
Received By rmcphers Date 2021-07-29 Time 09:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-08 Cont ID  
Sent By lmarchan Date 2021-06-08 Time 08:05 Rev Time 0.00
Received By lmarchan Date 2021-05-07 Time 09:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-25 Cont ID  
Sent By shill Date 2020-09-25 Time 10:52 Rev Time 0.00
Received By shill Date 2020-09-01 Time 15:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-08 Cont ID  
Sent By cthroop Date 2020-06-08 Time 15:31 Rev Time 0.00
Received By cthroop Date 2020-05-15 Time 07:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-09-02 Cont ID  
Sent By lmarchan Date 2021-09-02 Time 09:14 Rev Time 0.00
Received By lmarchan Date 2021-08-18 Time 14:01 Sent To  
Notes
2021-08-31 14:35:10RECEIPT MU-2021-041888 - $9948.86 PAID
2021-08-18 14:01:468/18/2021 EMAILED IMPACT FOR REVIEW-AO
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By rmcphers Date 2020-06-02 Time 15:59 Rev Time 0.00
Received By rmcphers Date 2020-06-02 Time 15:59 Sent To  
Notes
2020-06-02 16:00:46PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-05-14 Cont ID  
Sent By medwards Date 2021-05-14 Time 08:48 Rev Time 0.00
Received By medwards Date 2021-05-14 Time 08:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-02-16 Cont ID  
Sent By medwards Date 2020-09-09 Time 10:47 Rev Time 0.00
Received By medwards Date 2020-09-09 Time 09:07 Sent To  
Notes
2020-09-09 10:48:07 
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-05-27 Cont ID  
Sent By medwards Date 2020-05-27 Time 15:28 Rev Time 0.00
Received By medwards Date 2020-05-27 Time 13:17 Sent To  
Notes
2020-05-27 15:34:021ST REVIEW FBC-2017 MECHANICAL
 PERMIT -20020315
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) PLEASE SHOW A DETAIL DRAWING OF AHU AND THE DUCT
 WORK IN THE GARAGE. FBC RES R302.5.2
  
 2) SHOW A DETAIL DRAWING OF THE DRYER DUCTWORK IN THE
 GARAGE AT THE RATED WALL. FBC RES R302.5.3
  
 3) PLEASE PROVIDE THE MODEL NUMBERS FOR THE RANGE AND
 THE HOOD. FBC FS 107.2.1
  
 4) PROVIDE THE CFM?S OF THE HOOD, ALSO MAKEUP AIR. FBC
 FS 107.2.1
  
 5) IS THE FIREPLACE UNVENTED? PLEASE PROVIDE THE MODEL
 NUMBER FOR THE FIREPLACE. FBC FS 107.2.1
  
 6) PLEASE SHOW VENTING FOR THE FIREPLACE IN THE MASTER
 BEDROOM. FBC FS 107.2.1
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 14:16 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 14:11 Sent To  
Notes
2021-05-24 14:16:03FIRM = AE 7
 PROPOSED FINISHED FLOOR = 10.68 NAVD
 GARAGE = 7.68 NAVD - SHOWS PROPOSED FLOOD VENTS
 AC PAD = 9.18 NAVD

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2020-09-14 Cont ID  
Sent By rmcphers Date 2020-09-14 Time 14:31 Rev Time 0.00
Received By rmcphers Date 2020-09-14 Time 14:30 Sent To  
Notes
2020-09-14 14:31:38SEE BUILDING PLAN REVIEW.
 FLOOD ZONE (AE 7)
 FFE = 9.18
 GARAGE FLOOD VENTS =
 EQUIPMENT ELEVATION =

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By rmcphers Date 2020-06-02 Time 16:00 Rev Time 0.00
Received By rmcphers Date 2020-06-02 Time 16:00 Sent To  
Notes
2020-06-02 16:02:13SEE BUILDING PLAN REVIEW.
 FLOOD ZONE (AE 7)
 FFE =
 GARAGE FLOOD VENTS =
 EQUIPMENT ELEVATION =

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-06-07 Cont ID  
Sent By abelisle Date 2021-06-07 Time 18:57 Rev Time 0.00
Received By abelisle Date 2021-06-07 Time 18:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-09-02 Cont ID  
Sent By lcrespo Date 2020-09-02 Time 10:41 Rev Time 0.00
Received By lcrespo Date 2020-09-02 Time 10:41 Sent To  
Notes
2020-09-02 14:12:5109/02/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE SHOW THE DISTANCE BETWEEN THE SHOWER, WATER
 CLOSET AND BIDET TO BE 30" BETWEEN FIXTURES PER THE
 2017 FBC SEC. R 2705.1 GENERAL.
  
 2. BIDET SHALL HAVE A WATER TEMPERATURE NOT GREATER
 THAN 110 F BY A WATER-TEMPERATURE-LIMITING DEVICE
 CONFORMING TO ASSE 1070 OR CSA B125.3 PER THE 2017 FBC
 SEC. R 2721.2 BIDET WATER TEMPERATURE.
  
 3. ROMAN TUB HOT WATER SUPPLIED SHALL BE LIMITED TO A
 TEMPERATURE OF NOT GREATER THAN 120 F BY A WATER
 TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070
 OR CSA B125.3, EXCEPT WHERE SUCH PROTECTION IS
 OTHERWISE PROVIDED BY A COMBINATION TUB/SHOWER VALVE IN
 ACCORDANCE WITH SECTION P2708.4. IF TEMPERING VALVE IS
 INSTALLED IT SHALL HAVE AN ACCESS TO IT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-08 Cont ID  
Sent By cthroop Date 2020-06-08 Time 15:18 Rev Time 0.00
Received By cthroop Date 2020-06-08 Time 13:38 Sent To  
Notes
2020-06-08 15:29:58PLAN REVIEW - PLUMBING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SHOWER PAN DETAIL.
 P2709.1 SHOWER PAN CONSTRUCTION. FBC 107.2.1
  
 2. LABEL ALL PIPE SIZES ON SANITARY RISER.
 P3005.4DRAIN PIPE SIZING.
  
 3. PROVIDE WATER DISTRIBUTION RISER DIAGRAHM.
 P2903.1WATER SUPPLY SYSTEM DESIGN CRITERIA.THE WATER
 SERVICE AND WATER DISTRIBUTION SYSTEMS SHALL BE
 DESIGNED, AND PIPE SIZES SHALL BE SELECTED SUCH THAT
 UNDER CONDITIONS OF PEAK DEMAND, THE CAPACITIES AT THE
 POINT OF OUTLET DISCHARGE SHALL NOT BE LESS THAN SHOWN
 IN TABLE P2903.1.
  
 4. PROVIDE THERMOSTATIC SHOWER CONTROL VALVES.
 P2708.4SHOWER CONTROL VALVES. INDIVIDUAL SHOWER AND
 TUB/ SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH
 CONTROL VALVES OF THE PRESSURE-BALANCE,
 THERMOSTATIC-MIXING OR COMBINATION
 PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A
 HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME
 A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET
 TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN
 120?F (49?C). IN-LINE THERMOSTATIC VALVES SHALL NOT BE
 USED FOR COMPLIANCE WITH THIS SECTION.
  
  
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2021-08-18 Cont ID  
Sent By rmcphers Date 2021-08-18 Time 15:46 Rev Time 0.00
Received By rmcphers Date 2021-08-18 Time 15:46 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2021-08-09 Cont ID  
Sent By rmcphers Date 2021-08-09 Time 10:04 Rev Time 0.00
Received By rmcphers Date 2021-08-09 Time 10:04 Sent To  
Notes
2021-08-09 10:06:54NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) DRAWING A-4 SHOWS A TAPERED INSULATED ROOF. THE
 PROVIDED PRODUCT APPROVAL ROOFING SYSTEM IS FOR A NON
 INSULATED ROOF SYSTEM.
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2021-05-24 Cont ID  
Sent By rmcphers Date 2021-05-24 Time 14:09 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 14:04 Sent To  
Notes
2021-05-24 14:09:35NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) 2ND REVISION OF THE ROOFING PRODUCT APPROVAL
 PROVIDED DOES NOT SHOW A ROOFING SYSTEM TO BE USED -
 PLEASE CIRCLE A ROOFING SYSTEM TO BE USED ON THE
 PRODUCT APPROVAL - STARTING ON PAGE 8 OF THE PRODUCT
 APPROVAL. ROOFING SYSTEM TO BE USED ON THE PROVIDED
 PRODUCT APPROVAL MAY REQUIRE ADDITIONAL SIGNED AND
 SEALED ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER
 FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER
 PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL
 ( ) - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE
 PRODUCT APPROVAL.)
  
 2) ROOFING SYSTEMS PRODUCT APPROVALS MAY BE DEFERRED
 SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON THE
 CONSTRUCTION DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS.
 FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS
 ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE
 NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT
 ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2020-09-14 Cont ID  
Sent By rmcphers Date 2020-09-14 Time 14:32 Rev Time 0.00
Received By rmcphers Date 2020-09-14 Time 14:32 Sent To  
Notes
2020-09-14 14:32:24SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By rmcphers Date 2020-06-02 Time 16:04 Rev Time 0.00
Received By rmcphers Date 2020-06-02 Time 16:04 Sent To  
Notes
2020-06-02 16:04:38SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2021-09-03 Cont ID  
Sent By cthroop Date 2021-09-03 Time 16:32 Rev Time 0.00
Received By cthroop Date 2021-09-03 Time 16:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2021-08-18 Cont ID  
Sent By rmcphers Date 2021-08-18 Time 15:42 Rev Time 0.00
Received By rmcphers Date 2021-08-18 Time 15:42 Sent To  
Notes
2021-08-18 15:46:10SIGNATURE REVIEW
 DOCUMENT LABELED "ROOF ENGINEERING.PDF" IN PROJECTDOX
 DOES NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE READER
 - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR -
 IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-05-07 Cont ID  
Sent By medwards Date 2021-05-07 Time 14:53 Rev Time 0.00
Received By medwards Date 2021-05-07 Time 14:53 Sent To  
Notes
2021-05-07 15:00:56ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-14 Cont ID  
Sent By rmcphers Date 2020-09-14 Time 14:35 Rev Time 0.00
Received By rmcphers Date 2020-09-14 Time 14:32 Sent To  
Notes
2020-09-14 14:33:07SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By rmcphers Date 2020-06-02 Time 16:05 Rev Time 0.00
Received By rmcphers Date 2020-06-02 Time 16:05 Sent To  
Notes
2020-06-02 16:07:17ALL SIGNED AND SEALED DRAWINGS NEED TO BE DIGITALLY OR
 ELECTRONICALLY SIGNED BY THE ARCHITECT OR ENGINEER FOR
 USE IN PROJECTDOX.

Review Stop Z ZONING
Rev No 3 Status P Date 2021-05-25 Cont ID  
Sent By rthermid Date 2021-05-25 Time   Rev Time 0.00
Received By rthermid Date 2021-05-25 Time   Sent To I
Notes
2021-05-25 10:09:37SEPERATE PERMITS NEEDED FOR DRIVEWAY, POOLS, MECHANICAL
 EQUIPMENT AND ANY ADDITIONAL WORK ONSITE.
  
 RAFAELA THERMIDOR
 561-822-1443 - [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2020-09-22 Cont ID  
Sent By rthermid Date 2020-09-22 Time   Rev Time 0.00
Received By rthermid Date 2020-09-22 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-05-27 Cont ID  
Sent By rthermid Date 2020-05-27 Time   Rev Time  
Received By rthermid Date 2020-05-27 Time   Sent To I
Notes
2020-05-27 09:30:47ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 5/27/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY AS IT
 APPEARS PART OF THE POOL IS IN AN EASEMENT AND EXCEEDS
 THE 75% OR 1000 SQUARE FEET REQUIREMENT
 2. INDICATE THE SETBACK DIMENSIONS FROM PROPOSED POOL
 EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR) SECTION 94-305(B)(4): MECHANICAL
 EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A
 REQUIRED SETBACK.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST
 THAT IT BE SENT TO YOU BY EMAILING [email protected]
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1443
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG