Plan Review Details - Permit 20050311
Plan Review Stops For Permit 20050311
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By cthroop Date 2020-07-31 Time 06:53 Rev Time 0.00
Received By cthroop Date 2020-07-30 Time 15:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-06-10 Cont ID  
Sent By cthroop Date 2020-06-10 Time 16:38 Rev Time 0.00
Received By cthroop Date 2020-06-10 Time 14:23 Sent To  
Notes
2020-06-10 16:44:20NO NOTES

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By cthroop Date 2020-07-31 Time 06:38 Rev Time 0.00
Received By cthroop Date 2020-07-30 Time 15:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-05 Cont ID  
Sent By jleahy Date 2020-06-05 Time 13:08 Rev Time 0.00
Received By jleahy Date 2020-06-05 Time 13:03 Sent To  
Notes
2020-06-05 13:21:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 1) LOAD CALCULATION REQUIRED FOR 200A PANEL, LOAD
 CALCULATION ON STORAGE PANEL WHAT SECTION OF THE CODE
 DOES IT COME FROM?
  
 PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3
  
 2) GROUNDING ELECTRODE SYSTEM REQUIRED AT SEPARATE
 BUILDING.
  
 A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE
 ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND
 CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF
 GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC
 RE3607.3
  
 3) WHAT SIZE BREAKER IS FEEDING THE STORAGE UNIT? 215.5
  
 4) TANKLESS WATER HEATER AT 5700W CAN NOT BE INSTALLED
 ON A 60A BREAKER.
  
 5) AHU 2500W ON EACH PHASE OR 1250 ON EACH PHASE?
  
 6) STORAGE PANEL HAS MORE THAN 6 THROWS OF THE HAND TO
 SHUT OFF A MAIN BREAKER IS NEEDED,
  
 225.33 MAXIMUM NUMBER OF DISCONNECTS (A) GENERAL. TH E
 DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY 225.30
 SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR SIX
 CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN A
 GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A SWITCHBOARD
 OR SWITCHGEAR. THERE SHALL BE NO MORE THAN SIX
 DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-31 Cont ID  
Sent By cthroop Date 2020-07-31 Time 06:54 Rev Time 0.00
Received By cthroop Date 2020-07-20 Time 10:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-10 Cont ID  
Sent By cthroop Date 2020-06-10 Time 16:44 Rev Time 0.00
Received By cthroop Date 2020-05-26 Time 14:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2020-07-27 Cont ID  
Sent By medwards Date 2020-07-27 Time 11:44 Rev Time 0.00
Received By medwards Date 2020-07-27 Time 11:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-01 Cont ID  
Sent By hmoser Date 2020-06-01 Time 13:23 Rev Time 0.00
Received By hmoser Date 2020-06-01 Time 13:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By cthroop Date 2020-07-31 Time 06:53 Rev Time 0.00
Received By cthroop Date 2020-07-30 Time 15:31 Sent To  
Notes
2020-07-31 06:54:26PROVISO: SHOWER PAN LINING SHALL COMPLY WITH P2709.3.
 SHOWER CONTROL VALVE SHALL COMPLY WITH P2708 AND ASSE
 1016. CT

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-10 Cont ID  
Sent By cthroop Date 2020-06-10 Time 16:44 Rev Time 0.00
Received By cthroop Date 2020-06-10 Time 14:23 Sent To  
Notes
2020-06-10 16:47:33PLAN REVIEW - PLUMBING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE PLUMBING SANITARY RISER DIAGRAHM INDICATES A
 SINK WITH STUDOR VENT AS PART OF THE SYSTEM. NO SINK
 APPEARS ON PLUMBING PLAN.
 107.2 CONSTRUCTION DOCUMENTS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-08-13 Cont ID  
Sent By jgomez Date 2020-08-13 Time 17:58 Rev Time 0.00
Received By jgomez Date 2020-08-13 Time 17:58 Sent To  
Notes
2020-08-13 18:00:43DRAWINGS 01, D-1 AND E-1 MATCH DRAWINGS UPLOADED TO
 PROJECTDOX. DRAWINGS HAVE ENGINEER'S EMBOSSED SEAL AND
 ORIGINAL SIGNATURE. SENT TO STORAGE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-31 Cont ID  
Sent By cthroop Date 2020-07-31 Time 06:31 Rev Time 0.00
Received By cthroop Date 2020-07-30 Time 15:31 Sent To  
Notes
2020-07-31 06:32:25PLAN REVIEW - DIGITAL SIGNATURES AND SEALS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 EOR DAVID CABERA, P.E. HAS BEEN PREVIOUSLY NOTIFIED
 THAT PROFESSIONAL ENGINEER'S CANNOT SELF CERTIFY.
  
 DESIGN PROFESSIONALS
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
 OPTION -1:
 RE-SUBMIT PLANS WITH VALID SIGNATURE AND SEAL.
  
 OPTION - 2:
 YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH WET
 SEAL AND SIGNATURE OF DESIGN PROFESSIONAL PRIOR TO
 PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL
 FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT
 SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR
 INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND
 IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU
 TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS.
  
 OPTION - 3:
 YOU MAY MAIL IN A HARD COPY OF PLANS WITH WET SEAL AND
 SIGNATURE. A FINAL INSPECTION HOLD WILL BE PLACED ON
 YOUR PERMIT UNTIL DESIGN PROFESSIONALS SIGNATURE AND
 SEAL ARE VERIFIED.
  
 PLEASE ADVISE HOW YOU WISH TO PROCEED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-10 Cont ID  
Sent By cthroop Date 2020-06-10 Time 16:33 Rev Time 0.00
Received By cthroop Date 2020-06-10 Time 14:23 Sent To  
Notes
2020-06-10 16:38:09PLAN REVIEW - DIGITAL SIGNATURES AND SEALS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 EOR DAVID CABERA, P.E. HAS BEEN PREVIOUSLY NOTIFIED
 THAT PROFESSIONAL ENGINEER'S CANNOT SELF CERTIFY.
  
 DESIGN PROFESSIONALS
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
 OPTION -1:
 RE-SUBMIT PLANS WITH VALID SIGNATURE AND SEAL.
  
 OPTION - 2:
 YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH WET
 SEAL AND SIGNATURE OF DESIGN PROFESSIONAL PRIOR TO
 PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL
 FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT
 SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR
 INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND
 IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU
 TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS.
  
 OPTION - 3:
 YOU MAY MAIL IN A HARD COPY OF PLANS WITH WET SEAL AND
 SIGNATURE. A FINAL INSPECTION HOLD WILL BE PLACED ON
 YOUR PERMIT UNTIL DESIGN PROFESSIONALS SIGNATURE AND
 SEAL ARE VERIFIED.
  
 PLEASE ADVISE HOW YOU WISH TO PROCEED.
  
  
  
  