Plan Review Details - Permit 20050144
Plan Review Stops For Permit 20050144
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-09-22 Cont ID  
Sent By rmcdouga Date 2020-09-22 Time 07:12 Rev Time 0.00
Received By rmcdouga Date 2020-09-22 Time 07:11 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-07-30 Cont ID  
Sent By rmcdouga Date 2020-07-30 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2020-07-30 Time 08:27 Sent To  
Notes
2020-07-30 08:27:34PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-06-09 Cont ID  
Sent By rmcdouga Date 2020-06-09 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2020-06-09 Time 08:27 Sent To  
Notes
2020-06-09 08:44:38PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-30 Cont ID  
Sent By rmcdouga Date 2020-07-30 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2020-07-30 Time 08:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-09 Cont ID  
Sent By rmcdouga Date 2020-06-09 Time 08:28 Rev Time 0.00
Received By rmcdouga Date 2020-06-09 Time 08:28 Sent To  
Notes
2020-06-09 08:56:001ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.
  
 2) PROVIDE THE FOLLOWING INFORMATION FOR THE NEW TILE
 FLOORING :
  
 1. DESCRIPTION OF EXISTING SITE CONDITIONS:
 (A) THICKNESS OF SLAB (B) FLOOR/CEILING ASSEMBLY BELOW
 (EXPOSED CONCRETE, SUSPENDED GYPSUM OR ACOUSTICAL ).
 2. PROPOSED SOUND UNDERLAYMENT.
 3. TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON
 THE EXISTING SITE CONDITIONS. THE TEST REPORTS FOR THE
 SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE
 DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS.
 4. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S:
 E-84, E-90 & E-492.
  
 FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 FBC 603 COMBUSTIBLE MATERIAL IN TYPE I AND II
 CONSTRUCTION
 603.1 ALLOWABLE MATERIALS.
 COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS
 OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING
 APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1
 THROUGH 603.1.3:
 2. THERMAL AND ACOUSTICAL INSULATION, OTHER THAN FOAM
 PLASTICS, HAVING A FLAME SPREAD INDEX OF NOT MORE THAN
 25.
 EXCEPTIONS:
 1. INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
 2. INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND
 SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
  
 3. FOAM PLASTICS IN ACCORDANCE WITH CHAPTER 26.
  
  
 FBC 2603 FOAM PLASTIC INSULATION
 2603.3 SURFACE-BURNING CHARACTERISTICS.
 UNLESS OTHERWISE INDICATED IN THIS SECTION, FOAM
 PLASTIC INSULATION AND FOAM PLASTIC CORES OF
 MANUFACTURED ASSEMBLIES SHALL HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 75 AND A SMOKE-DEVELOPED INDEX OF NOT
 MORE THAN 450 WHERE TESTED IN THE MAXIMUM THICKNESS
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E 84 OR UL
 723. LOOSE FILL-TYPE FOAM PLASTIC INSULATION SHALL BE
 TESTED AS BOARD STOCK FOR THE FLAME SPREAD AND
 SMOKE-DEVELOPED

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-17 Cont ID  
Sent By jleahy Date 2020-09-17 Time 10:57 Rev Time 0.00
Received By jleahy Date 2020-09-17 Time 10:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-07-21 Cont ID  
Sent By jleahy Date 2020-07-21 Time 07:45 Rev Time 0.00
Received By jleahy Date 2020-07-21 Time 07:40 Sent To  
Notes
2020-07-21 07:50:30ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PLAN IS NOT CLEAR AS TO WHERE NEW LED LIGHTS ARE GOING?
  
 FAN IN BREAKFAST ROOM IS IT NEW?
  
 NEED TO SHOW ELECTRIC IN NEW ISLAND AND LOCATION OF
 OUTLETS.
  
 NEED TO SHOW NEW LIGHTING AND OUTLETS EXACT LOCATIONS.
  
 REPLACING ALL OUTLETS AND SWITCHES REQUIRES ARC FAULT
 PROTECTION PER 406.4(D)(4)
  
 406.4(D) REPLACEMENTS. REPLACEMENT OF RECEPTACLES SHALL
 COMPLY WITH 40 6.4(D)(1) THROUGH (D)(6), AS APPLICABLE.
 ARC-FAULT CIRCUITINTERRUPTER TYPE AND GROUND-FAULT
 CIRCUIT-INTERRUPTER TYPE RECEPTACLES SHALL BE INSTALLED
 IN A READILY ACCESSIBLE LOCATION.
 (4) ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. WHERE A
 RECEPTACLE OUTLET IS SUPPLIED BY A BRANCH CIRCUIT THAT
 REQUIRES ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION AS
 SPECIFIED ELSEWHERE IN THIS CODE, A REPLACEMENT
 RECEPTACLE AT THIS OUTLET SHALL BE ONE OF THE
 FOLLOWING: (1) A LISTED OUTLET BRANCH-CIRCUIT TYPE
 ARC-FAULT CIRCUIT-INTERRUPTER RECEPTACLE (2) A
 RECEPTACLE PROTECTED BY A LISTED OUTLET BRANCH-CIRCUIT
 TYPE ARC-FAULT CIRCUIT-INTERRUPTER TYPE RECEPTACLE (3)
 A RECEPTACLE PROTECTED BY A LISTED COMBINATION TYPE
 ARCFAULT CIRCUIT-INTERRUPTER TYPE CIRCUIT BREAKER THIS
 REQUIREMENT BECOMES EFFECTIVE JANUARY 1, 2014.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-03 Cont ID  
Sent By jpearson Date 2020-06-03 Time 14:18 Rev Time 0.00
Received By jpearson Date 2020-06-03 Time 14:08 Sent To  
Notes
2020-06-03 14:18:43CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW THAT IS DESIGNED
 BY AND SIGNED AND SEALED BY A LICENSED DESIGN
 PROFESSIONAL OR DESIGNED BY AND SIGNED BY THE
 ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H);
 471.025; WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-09-21 Cont ID  
Sent By pleduc Date 2020-09-21 Time   Rev Time 0.00
Received By pleduc Date 2020-09-17 Time 13:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2020-07-21 Cont ID  
Sent By pleduc Date 2020-07-21 Time   Rev Time 0.00
Received By pleduc Date 2020-07-21 Time 09:01 Sent To  
Notes
2020-07-21 09:13:53PREVIOUS COMMENTS NOT ADDRESSED.
  
 PREVIOUS COMMENTS REPOSTED:
  
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF EXISTING FIRE SPRINKLER
 OR FIRE ALARM SYSTEMS.
  
 ANY WORK ON THE WALLS AND CEILINGS AFFECT FIRE ALARM
 DEVICES AND COVERAGE.
  
 ANY WORK ON THE FA SYSTEM SHALL BE DONE UNDER SPERATE
 PERMITS AND SHOP DRAWINGS.
  
 PLEASE PROVIDE DETAILS AND PROVIDE AN APPLICABLE NOTE
 OF ACKNOWLEDGEMENT.
  
  
  
 2) THERE APPEARS TO BE NEW DOORS; HOWEVER, THERE IS NO
 DOOR SCHEDULE.
  
 PLEASE PROVIDE DETAILS.
  
  
 3) THERE IS INDICATIONS OF NEW TILE; HOWEVER, THERE IS
 NO UNDERLAYMENT.
  
 PER NFPA 31, EXISTING APARTMENT BUILDINGS
  
 31.3.3 INTERIOR FINISH.
 31.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH SECTION
 10.2.
  
 PLEASE PROVIDE DETAILS.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-06-03 Cont ID  
Sent By pleduc Date 2020-06-03 Time   Rev Time 0.00
Received By pleduc Date 2020-06-03 Time 14:24 Sent To  
Notes
2020-06-03 14:41:21THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF EXISTING FIRE SPRINKLER
 OR FIRE ALARM SYSTEMS.
  
 ANY WORK ON THE WALLS AND CEILINGS AFFECT FIRE ALARM
 DEVICES AND COVERAGE.
  
 ANY WORK ON THE FA SYSTEM SHALL BE DONE UNDER SPERATE
 PERMITS AND SHOP DRAWINGS.
  
 PLEASE PROVIDE DETAILS AND PROVIDE AN APPLICABLE NOTE
 OF ACKNOWLEDGEMENT.
  
  
  
 2) THERE APPEARS TO BE NEW DOORS; HOWEVER, THERE IS NO
 DOOR SCHEDULE.
  
 PLEASE PROVIDE DETAILS.
  
  
 3) THERE IS INDICATIONS OF NEW TILE; HOWEVER, THERE IS
 NO UNDERLAYMENT.
  
 PER NFPA 31, EXISTING APARTMENT BUILDINGS
  
 31.3.3 INTERIOR FINISH.
 31.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH SECTION
 10.2.
  
 PLEASE PROVIDE DETAILS.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-21 Cont ID  
Sent By ccarvaja Date 2020-09-21 Time 16:15 Rev Time 0.00
Received By ccarvaja Date 2020-09-16 Time 10:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-30 Cont ID  
Sent By rmcdouga Date 2020-07-30 Time 08:28 Rev Time 0.00
Received By rmcdouga Date 2020-07-20 Time 13:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-09 Cont ID  
Sent By rmcdouga Date 2020-06-09 Time 08:42 Rev Time 0.00
Received By rmcdouga Date 2020-05-18 Time 10:05 Sent To  
Notes
2020-05-18 10:08:285/18/2020 WILL CONVERT TO DIGITAL RES
2020-05-11 15:11:5505/11/2020 TALKED TO SAMANTHA. NO FEES PAID. PLAN
 REVIEWS NOT PERFORMED. SENT TO LIBRARY UNDER "FEES NO
 PAID". JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-09-15 Cont ID  
Sent By medwards Date 2020-09-15 Time 14:28 Rev Time 0.00
Received By medwards Date 2020-09-15 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-08-28 Cont ID  
Sent By medwards Date 2020-08-28 Time 15:09 Rev Time 0.00
Received By medwards Date 2020-08-28 Time 15:09 Sent To  
Notes
2020-08-28 15:11:24PLEASE SHOW MECHANICAL WORK BEING DONE UNDER THIS
 REPORT. NOTE ON BOTTOM OF PAGE IS NOT ACCEPTABLE AS
 THERE IS NO SCOPE OF WORK FOR THE MECHANICAL SYSTEM.
 FBC FS 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-07-22 Cont ID  
Sent By ccole Date 2020-07-22 Time 10:30 Rev Time 0.00
Received By ccole Date 2020-07-22 Time 07:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-05 Cont ID  
Sent By ccole Date 2020-06-05 Time 07:53 Rev Time 0.00
Received By ccole Date 2020-06-05 Time 07:25 Sent To  
Notes
2020-06-05 08:04:161ST REVIEW FBC-2017 PLUMBING
 PERMIT 20050144
 6/5/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE PLUMBING PLANS FOR THE PROPOSED PROJECT THAT
 INCLUDE:
 A) A NARRATIVE SCOPE OF WORK.
 B) SANITARY ISOMETRIC AND WATER RISER DRAWINGS.
 C) CONSTRUCTION DETAILS FOR THE NEW SHOWER PAN AND
 SHOWER FLOOR AND WALLS.
  
 REFER TO SECTIONS 107.2.1 AND 107.3.5.1.3 WPB; AND
 SECTIONS 602.1, 701.1, 901.1.2.1, 417.1- 417.6 FBC P.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-17 Cont ID  
Sent By jleahy Date 2020-09-17 Time 10:57 Rev Time 0.00
Received By jleahy Date 2020-09-17 Time 10:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-30 Cont ID  
Sent By rmcdouga Date 2020-07-30 Time 08:28 Rev Time 0.00
Received By rmcdouga Date 2020-07-30 Time 08:28 Sent To  
Notes
***NONE***