| Plan Review Stops For Permit 20050144 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-22 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-22 |
Time |
07:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2020-07-30 08:27:34 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-06-09 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-06-09 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2020-06-09 08:44:38 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-06-09 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-06-09 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2020-06-09 08:56:00 | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2) PROVIDE THE FOLLOWING INFORMATION FOR THE NEW TILE | | | FLOORING : | | | | | | 1. DESCRIPTION OF EXISTING SITE CONDITIONS: | | | (A) THICKNESS OF SLAB (B) FLOOR/CEILING ASSEMBLY BELOW | | | (EXPOSED CONCRETE, SUSPENDED GYPSUM OR ACOUSTICAL ). | | | 2. PROPOSED SOUND UNDERLAYMENT. | | | 3. TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON | | | THE EXISTING SITE CONDITIONS. THE TEST REPORTS FOR THE | | | SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE | | | DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS. | | | 4. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S: | | | E-84, E-90 & E-492. | | | | | | FBC 603.1 FLAME SPREAD - ASTM E 84-09 | | | | | | FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | FBC 603 COMBUSTIBLE MATERIAL IN TYPE I AND II | | | CONSTRUCTION | | | 603.1 ALLOWABLE MATERIALS. | | | COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS | | | OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING | | | APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1 | | | THROUGH 603.1.3: | | | 2. THERMAL AND ACOUSTICAL INSULATION, OTHER THAN FOAM | | | PLASTICS, HAVING A FLAME SPREAD INDEX OF NOT MORE THAN | | | 25. | | | EXCEPTIONS: | | | 1. INSULATION PLACED BETWEEN TWO LAYERS OF | | | NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING | | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 100. | | | 2. INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND | | | SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE | | | ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN | | | 200. | | | | | | 3. FOAM PLASTICS IN ACCORDANCE WITH CHAPTER 26. | | | | | | | | | FBC 2603 FOAM PLASTIC INSULATION | | | 2603.3 SURFACE-BURNING CHARACTERISTICS. | | | UNLESS OTHERWISE INDICATED IN THIS SECTION, FOAM | | | PLASTIC INSULATION AND FOAM PLASTIC CORES OF | | | MANUFACTURED ASSEMBLIES SHALL HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 75 AND A SMOKE-DEVELOPED INDEX OF NOT | | | MORE THAN 450 WHERE TESTED IN THE MAXIMUM THICKNESS | | | INTENDED FOR USE IN ACCORDANCE WITH ASTM E 84 OR UL | | | 723. LOOSE FILL-TYPE FOAM PLASTIC INSULATION SHALL BE | | | TESTED AS BOARD STOCK FOR THE FLAME SPREAD AND | | | SMOKE-DEVELOPED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-17 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-17 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-21 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-21 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2020-07-21 07:50:30 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLAN IS NOT CLEAR AS TO WHERE NEW LED LIGHTS ARE GOING? | | | | | | FAN IN BREAKFAST ROOM IS IT NEW? | | | | | | NEED TO SHOW ELECTRIC IN NEW ISLAND AND LOCATION OF | | | OUTLETS. | | | | | | NEED TO SHOW NEW LIGHTING AND OUTLETS EXACT LOCATIONS. | | | | | | REPLACING ALL OUTLETS AND SWITCHES REQUIRES ARC FAULT | | | PROTECTION PER 406.4(D)(4) | | | | | | 406.4(D) REPLACEMENTS. REPLACEMENT OF RECEPTACLES SHALL | | | COMPLY WITH 40 6.4(D)(1) THROUGH (D)(6), AS APPLICABLE. | | | ARC-FAULT CIRCUITINTERRUPTER TYPE AND GROUND-FAULT | | | CIRCUIT-INTERRUPTER TYPE RECEPTACLES SHALL BE INSTALLED | | | IN A READILY ACCESSIBLE LOCATION. | | | (4) ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. WHERE A | | | RECEPTACLE OUTLET IS SUPPLIED BY A BRANCH CIRCUIT THAT | | | REQUIRES ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION AS | | | SPECIFIED ELSEWHERE IN THIS CODE, A REPLACEMENT | | | RECEPTACLE AT THIS OUTLET SHALL BE ONE OF THE | | | FOLLOWING: (1) A LISTED OUTLET BRANCH-CIRCUIT TYPE | | | ARC-FAULT CIRCUIT-INTERRUPTER RECEPTACLE (2) A | | | RECEPTACLE PROTECTED BY A LISTED OUTLET BRANCH-CIRCUIT | | | TYPE ARC-FAULT CIRCUIT-INTERRUPTER TYPE RECEPTACLE (3) | | | A RECEPTACLE PROTECTED BY A LISTED COMBINATION TYPE | | | ARCFAULT CIRCUIT-INTERRUPTER TYPE CIRCUIT BREAKER THIS | | | REQUIREMENT BECOMES EFFECTIVE JANUARY 1, 2014. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-06-03 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-06-03 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2020-06-03 14:18:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW THAT IS DESIGNED | | | BY AND SIGNED AND SEALED BY A LICENSED DESIGN | | | PROFESSIONAL OR DESIGNED BY AND SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-09-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-17 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-21 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2020-07-21 09:13:53 | PREVIOUS COMMENTS NOT ADDRESSED. | | | | | | PREVIOUS COMMENTS REPOSTED: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF EXISTING FIRE SPRINKLER | | | OR FIRE ALARM SYSTEMS. | | | | | | ANY WORK ON THE WALLS AND CEILINGS AFFECT FIRE ALARM | | | DEVICES AND COVERAGE. | | | | | | ANY WORK ON THE FA SYSTEM SHALL BE DONE UNDER SPERATE | | | PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE DETAILS AND PROVIDE AN APPLICABLE NOTE | | | OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 2) THERE APPEARS TO BE NEW DOORS; HOWEVER, THERE IS NO | | | DOOR SCHEDULE. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 3) THERE IS INDICATIONS OF NEW TILE; HOWEVER, THERE IS | | | NO UNDERLAYMENT. | | | | | | PER NFPA 31, EXISTING APARTMENT BUILDINGS | | | | | | 31.3.3 INTERIOR FINISH. | | | 31.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH SECTION | | | 10.2. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-06-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-03 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2020-06-03 14:41:21 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF EXISTING FIRE SPRINKLER | | | OR FIRE ALARM SYSTEMS. | | | | | | ANY WORK ON THE WALLS AND CEILINGS AFFECT FIRE ALARM | | | DEVICES AND COVERAGE. | | | | | | ANY WORK ON THE FA SYSTEM SHALL BE DONE UNDER SPERATE | | | PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE DETAILS AND PROVIDE AN APPLICABLE NOTE | | | OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 2) THERE APPEARS TO BE NEW DOORS; HOWEVER, THERE IS NO | | | DOOR SCHEDULE. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 3) THERE IS INDICATIONS OF NEW TILE; HOWEVER, THERE IS | | | NO UNDERLAYMENT. | | | | | | PER NFPA 31, EXISTING APARTMENT BUILDINGS | | | | | | 31.3.3 INTERIOR FINISH. | | | 31.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH SECTION | | | 10.2. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-21 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-09-21 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2020-09-16 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-06-09 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-05-18 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2020-05-18 10:08:28 | 5/18/2020 WILL CONVERT TO DIGITAL RES | | 2020-05-11 15:11:55 | 05/11/2020 TALKED TO SAMANTHA. NO FEES PAID. PLAN | | | REVIEWS NOT PERFORMED. SENT TO LIBRARY UNDER "FEES NO | | | PAID". JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-15 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-28 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-28 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2020-08-28 15:11:24 | PLEASE SHOW MECHANICAL WORK BEING DONE UNDER THIS | | | REPORT. NOTE ON BOTTOM OF PAGE IS NOT ACCEPTABLE AS | | | THERE IS NO SCOPE OF WORK FOR THE MECHANICAL SYSTEM. | | | FBC FS 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-22 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-22 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-06-05 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-06-05 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2020-06-05 08:04:16 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT 20050144 | | | 6/5/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE PLUMBING PLANS FOR THE PROPOSED PROJECT THAT | | | INCLUDE: | | | A) A NARRATIVE SCOPE OF WORK. | | | B) SANITARY ISOMETRIC AND WATER RISER DRAWINGS. | | | C) CONSTRUCTION DETAILS FOR THE NEW SHOWER PAN AND | | | SHOWER FLOOR AND WALLS. | | | | | | REFER TO SECTIONS 107.2.1 AND 107.3.5.1.3 WPB; AND | | | SECTIONS 602.1, 701.1, 901.1.2.1, 417.1- 417.6 FBC P. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-17 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-17 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-30 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|