Plan Review Details - Permit 20050060
Plan Review Stops For Permit 20050060
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-07-21 Cont ID  
Sent By jwitmer Date 2020-07-21 Time 15:07 Rev Time 0.00
Received By jwitmer Date 2020-07-21 Time 14:30 Sent To  
Notes
2020-07-21 15:07:15NOT REQUIRED, NEW BUILDING 2015. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-11 Cont ID  
Sent By jwitmer Date 2020-09-11 Time 16:00 Rev Time 0.00
Received By jwitmer Date 2020-09-11 Time 15:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-07-21 Cont ID  
Sent By jwitmer Date 2020-07-21 Time 15:07 Rev Time 0.00
Received By jwitmer Date 2020-07-21 Time 14:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-20 Cont ID  
Sent By fgiaquin Date 2020-08-20 Time 20:14 Rev Time 0.00
Received By fgiaquin Date 2020-08-20 Time 19:34 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-03-01 Cont ID  
Sent By fgiaquin Date 2021-03-01 Time 20:38 Rev Time 0.00
Received By fgiaquin Date 2021-03-01 Time 19:47 Sent To  
Notes
2021-03-01 20:19:48APPROVED FOR LOW VOLTAGE "DATA' ONLY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-09-10 Cont ID  
Sent By pleduc Date 2020-09-10 Time   Rev Time 0.00
Received By pleduc Date 2020-09-10 Time 11:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-07-17 Cont ID  
Sent By sathomas Date 2020-07-17 Time 00:00 Rev Time 0.00
Received By sathomas Date 2020-07-17 Time 00:00 Sent To M
Notes
2020-07-17 10:11:29PROVISO:
  
 1. PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 2. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
 3. UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 S. THOMAS
 561-804-4728
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-15 Cont ID  
Sent By jesmith Date 2020-09-15 Time 11:50 Rev Time 0.00
Received By jesmith Date 2020-09-15 Time 11:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By fgiaquin Date 2020-08-20 Time 20:14 Rev Time 0.00
Received By fgiaquin Date 2020-07-14 Time 13:28 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-07-21 Cont ID  
Sent By jwitmer Date 2020-07-21 Time 15:06 Rev Time 0.00
Received By jwitmer Date 2020-07-21 Time 14:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-08-07 Cont ID  
Sent By hmoser Date 2020-08-07 Time 12:33 Rev Time 0.00
Received By hmoser Date 2020-08-07 Time 12:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-09-15 Cont ID  
Sent By jsmith Date 2020-09-15 Time 11:50 Rev Time 0.00
Received By jesmith Date 2020-09-15 Time 10:02 Sent To  
Notes
2020-09-15 11:50:1720050060 1791 PALM BEACH LAKES BLVD # W113
  
 PLUMBING COMMENTS: APPROVED
  
 PROVISOS/CLARIFICATIONS: SEE APPROVED PLAN P-100
  
 1. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE
 AS A DEFERRED SUBMITTAL, A SLAB REPAIR DETAIL FOR
 REVIEW AND ONCE APPROVED HAVE TWO (2) COPIES AT THE JOB
 SITE PRIOR TO THE FIRST INSPECTION. SHOW THE WIDTH OF
 THE REPAIR, THE MINIMUM THICKNESS OF THE CONCRETE TO BE
 REPLACED, AND THE PSI OF THE CONCRETE. SHOW THE SIZE
 AND LENGTH OF THE DOWELS, THE MINIMUM EMBEDMENT INTO
 THE EXISTING SLAB, THE ANCHORING MATERIAL FOR THE
 DOWELS AND THE SPACING OF THE DOWELS ON CENTER. THE
 REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL
 AND THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR THE FINAL INSPECTION. PROCEED AT YOUR OWN RISK.
 2. PER FBC PL 608.3, A LEAD FREE BACKFLOW PREVENTER
 SHALL BE PROVIDED IN-LINE AT THE CONNECTION FOR THE
 WATER COOLER
 3. PER FBC PL 504.2, PROVIDE VACUUM RELIEF VALVE, NOT
 VACUUM BREAKER AT COLD WATER TO WATER HEATER
  
 PROVISOS/CLARIFICATIONS: SEE REDLINED A-203
  
 1. A-203/DETAIL 9: PER FBC 1210.2.2 AND FBC PL 310.3,
 THE FIBERGLASS PANEL IS REQUIRED AT THE MOP BASIN
 2. THE CENTERLINE OF THE WATER CLOSET SHALL BE 16
 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL
 OR PARTITION PER FBC ACC 604.2
 3. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 4. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM
 MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE
 SPRUNG TO RETURN TO A LIFTED POSITION PER FBC ACC
 604.4.
 5. PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE PER FBC ACC 609.4
 6. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND PER FBC ACC 603.3
  
2020-09-10 16:08:41FOR JERRY SMITH

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-13 Cont ID  
Sent By jesmith Date 2020-08-13 Time 14:28 Rev Time 0.00
Received By jesmith Date 2020-08-13 Time 09:43 Sent To  
Notes
2020-08-13 14:25:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20050060 1791 PALM BEACH LAKES BLVD # W113
  
 1ST REVIEW
 PLUMBING COMMENTS:
  
 I. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 II. THIS IS AN ALTERATION AS DESCRIBED IN FBC
 DEFINITIONS. EXISTING TOILET ROOM TO REMAIN SHALL
 COMPLY WITH ALL PROVISIONS OF THE 2017 FLORIDA BUILDING
 CODES INCLUDING BUT NOT LIMITED TO THE ACCESSIBILITY
 REQUIREMENTS AND WALL FINISHES AS WELL AS THE
 REQUIREMENTS OF THE 2017 WEST PALM BEACH AMENDMENTS TO
 THE FLORIDA BUILDING CODE.
  
 1. REGARDING P-100 PLUMBING PLAN, PER WPB FBC 107.2.1,
 THE PLUMBING FIXTURE SCHEDULE FOR THE EXISTING TOILET
 ROOM SHALL BE AVAILABLE FOR REVIEW AND SHOW COMPLIANCE
 WITH THE 2017 FLORIDA BUILDING CODES. DO NOT CROSS OUT,
 BUT NOTE AS EXISTING IF THEY ARE COMPLIANT, OTHERWISE
 SPECIFY COMPLIANT FIXTURES.
 2. REGARDING P-100 PLUMBING PLAN, PER WPB FBC 107.2.1,
 THE WATER RISER DIAGRAM SHALL REFLECT THE NOTE
 REQUIRING THE WATER SUPPLY CONNECTION TO THE WATER
 COOLER. IF THE CONNECTION IS TO BE INTEGRATED WITH THE
 EXISTING PIPING THEN THE EXISTING PIPING SHALL BE
 SHOWN.
 3. REGARDING P-100 PLUMBING PLAN, DOES THE WATER COOLER
 HAVE A DRAIN? IS IT GOING TO PROVIDE FILTERED WATER TO
 THE END USER? WILL IT PROVIDE HOT WATER AND CHILLED
 COLD WATER? PER WPB FBC 107.2.1, PROVIDE A
 MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL FOR
 THE WATER COOLER.
 4. REGARDING P-100 PLUMBING PLAN, THE AO SMITH DEL 6
 ELECTRIC WATER HEATER IS A BOTTOM FED WATER HEATER AND
 REQUIRES A VACUUM RELIEF VALVE IN THE COLD WATER SUPPLY
 PER FBC PL 504.2. ADDITIONALLY, IS THE CHECK VALVE IN
 THE COLD WATER LINE NECESSARY? THERE APPARENTLY IS NO
 RECIRCULATING HOT WATER AND THERE IS THE REQUIRED
 THERMAL EXPANSION PROTECTION IN PLACE. PLEASE CLARIFY.
 5. REGARDING P-100 PLUMBING PLAN, PROVIDE DETAIL FOR
 THE WATER HEATER SUPPORT BRACKET AND ANCHORS PER WPB
 FBC 107.2.1.
 6. PER FBC PL 606.1(5), FULL-OPEN VALVES SHALL BE
 INSTALLED ON THE TOP OF EVERY WATER DOWN-FEED PIPE IN
 OCCUPANCIES OTHER THAN ONE- AND TWO-FAMILY RESIDENTIAL
 OCCUPANCIES.
 7. REGARDING THE MOP SINK AND THE EXISTING TOILET ROOM,
 PER WPB 107.2.1, WALLS AND PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE.
  
 III. PER WPB 107.2.1, PROVIDE DETAILS FOR THE
 ACCESSIBLE PLUMBING FIXTURES IN THE EXISTING BATHROOM
 AND FOR THE NEW ACCESSIBLE DRINKING FOUNTAIN(S).
  
 A. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2
 B. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 C. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL PER FBC ACC 604.5.1
 D. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 E. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
 HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH 309.
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET PER FBC ACC 604.6
 F. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 G. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES
 (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS
 SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION PER
 FBC ACC 604.4.
 H. PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP (NOT
 THE CENTER) OF THE GRIPPING SURFACE,
 I. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE
 FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 J. UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED PER FBC ACC 602.2
 K. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
 L. DRINKING FOUNTAIN SHALL COMPLY WITH FBC ACC 306 KNEE
 AND TOE CLEARANCE, 307 PROTRUDING OBJECTS, 309 OPERABLE
 PARTS, 602.4 SPOUT HEIGHT, 602.5 SPOUT LOCATION 602.6
 WATER FLOW AND 602.7 DRINKING FOUNTAIN FOR STANDING
 PERSON
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE PLUMBING COMMENTS
 FROM THE FIRST REVIEW.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20050060 1791 PALM BEACH LAKES BLVD # W113
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-11 Cont ID  
Sent By jwitmer Date 2020-09-11 Time 16:00 Rev Time 0.00
Received By jwitmer Date 2020-09-11 Time 15:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-20 Cont ID  
Sent By fgiaquin Date 2020-08-20 Time 20:15 Rev Time 0.00
Received By fgiaquin Date 2020-08-20 Time 20:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-08-18 Cont ID  
Sent By eschneid Date 2020-08-18 Time 15:16 Rev Time 0.50
Received By eschneid Date 2020-08-18 Time 15:16 Sent To  
Notes
***NONE***