Plan Review Details - Permit 20041058
Plan Review Stops For Permit 20041058
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-09-08 Cont ID  
Sent By ccole Date 2020-09-08 Time 14:29 Rev Time 0.00
Received By ccole Date 2020-09-08 Time 14:29 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By jwitmer Date 2020-06-16 Time 16:16 Rev Time 0.00
Received By jwitmer Date 2020-06-16 Time 13:02 Sent To  
Notes
2020-06-16 16:14:19PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2021-03-03 Time 13:14 Rev Time 0.00
Received By jwitmer Date 2021-03-02 Time 08:32 Sent To  
Notes
2021-03-03 13:16:112017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20041058
 ADD: 650 BELVEDERE RD.
 CONT: NUNNO BUILDERS
 TEL: 954-961-0777
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: WED. MARCH 03RD /2021
 ACTION: BUILDING PROVISO
  
 1) BUILDING PROVISO: THE NEW ENCLOSED COOLER/ FREEZER
 (399 SQ. FT.) TO BE UNDER A SEPARATE PERMIT, REVIEW AND
 ASSOCIATED FEES.
  
 2A) THE DESIGNER OF RECORD HAS REQUESTED THAT ALL
 COMPONENTS & CLADDING PRODUCT APPROVALS BE DEFERRED
 SUBMITTALS, AFTER PERMIT ISSUANCE.
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 2B) DEFERRED SUBMITTAL/ PROVISO. IDENTIFY GLAZING/
 MULLIONS. PLEASE IDENTIFY ON THE PRODUCT APPROVAL
 BEFORE SUBMITTING TO DESIGNER OF RECORD AND BEFORE
 SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS
 WITH GLAZING, PLEASE IDENTIFY THE OPENING WIDTH &
 HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
 UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 3) BUILDING PROVISO: WELDED OR BOLTED CONNECTIONS. THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION. THIRD PARTY
 CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE
 CHIEF BUILDING INSPECTOR KEN CONRAD AT 561-805-6666.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-09-15 Cont ID  
Sent By jwitmer Date 2020-09-15 Time 12:10 Rev Time 0.00
Received By jwitmer Date 2020-09-15 Time 10:16 Sent To  
Notes
2020-09-15 12:09:582017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20041058
 ADD: 650 BELVEDERE RD.
 CONT: NUNNO BUILDERS
 TEL: 954-961-0777
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. SEPT. 15TH /2020
 ACTION: DENIED
  
 1) SHEET C-102 SEMI-COMPLIED. IN THE UPPER RIGHT-HAND
 CORNER OF THE PLAN THE W. P. B. CITY STANDARD IS SOWN
 WITH 4-INCH-WIDE STRIPES. FURTHER DOWN THE SAME PAGE
 THERE IS ANOTHER ACCESSIBLE STRIPING REVISION DETAIL
 WITH THE LINE TYPE A & B BOTH 6-INCH STIPES PLEASE
 CORRECT OR XXX THROUGH THIS REVISION.
  
 1ST ROUND OF COMMENTS. 2017 ACCESSIBILITY CODE SECTION
 502.2 VEHICLE SPACES. EACH PARKING SPACE MUST BE AT
 LEAST 12 FEET WIDE, SHALL BE MARKED TO DEFINE THE
 WIDTH, AND SHALL HAVE AN ADJACENT ACCESS AISLE
 COMPLYING WITH 502.3.
 ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR
 OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT
 MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS.
 WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485
 ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL
 PAINTING.
  
 2) 2ND REQUEST. BOTH SHEETS C-100 & SHEET AR1 LIST THE
 ADDITION OF THE FREEZERS AS 458 SQ. FT. = 400SQ.FT= 858
 SQ. FT. IN THE 2017 FBC-B SECTION 2603.4.1.3 IN NON-
 SPRINKLERED BUILDINGS LIMITS THE AGGREGATE FLOOR AREA
 (TOTAL FLOOR AREA) TO 400 SQ. FT.
  
 3-4) COMPLIED.
  
 5) COMPLIED, MISSING PRODUCT APPROVALS ADDED TO LIST.
 SHEET A2.0.
  
 6A) 2ND REQUEST. RESPONSE STATES PLEASE SEE REVIEWED &
 STAMPED PRODUCT APPROVALS. NONE WERE SUBMITTED. ARE ALL
 OF THE COMPONENT & CLADDING GOING TO BE DEFERRED
 SUBMITTALS?
 1ST ROUND COMMENTS. W. P. B. 107.3.4. PRODUCT
 APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY
 FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6B) COMPLIED/ ACKNOWLEDGED. DELEGATED ENGINEERING.
 61G15-30.003 ENGINEERING DOCUMENT CLASSIFICATION. FL
 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL FORWARD
 THE DELEGATED ENGINEERING DOCUMENTS TO THE ENGINEER OF
 RECORD FOR REVIEW.
  
 6C) SEMI-COMPLIED. RESPONSE LIST OF DEFERRED SUBMITTALS
 DOES NOT INCLUDE THE SINGLE PLY ROOF SYSTEM.
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 7)DEFERRED SUBMITTAL/ PROVISO. IDENTIFY GLAZING/
 MULLIONS. PLEASE IDENTIFY ON THE PRODUCT APPROVAL
 BEFORE SUBMITTING TO DESIGNER OF RECORD AND BEFORE
 SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS
 WITH GLAZING, PLEASE IDENTIFY THE OPENING WIDTH &
 HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
 UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 8)) COMPLIED
  
 9) BUILDING PROVISO: WELDED OR BOLTED CONNECTIONS. THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION. THIRD PARTY
 CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 10) 109.3* BUILDING PERMIT VALUATION.ACKNOWLEGED. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, PLUMBING,
 MECHANICAL, INTERIOR FINISHES, NORMAL SITE WORK
 (EXCAVATION AND BACKFILL FOR BUILDINGS), ARCHITECTURAL
 AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT;
 EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS, ETC.) WITH REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY THE INTERNATIONAL CODE CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL
 TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED
 SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE,
 LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR
 FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE
 REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By jwitmer Date 2020-06-16 Time 16:16 Rev Time 0.00
Received By jwitmer Date 2020-06-16 Time 13:02 Sent To  
Notes
2020-06-16 16:13:142017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20041058
 ADD: 650 BELVEDERE RD.
 CONT: NUNNO BUILDERS
 TEL: 954-961-0777
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JUNE 15TH /2020
 ACTION: DENIED
  
 1) SHEET C-100 SHOWS THE PARKING LOT WITH SINGLE LINE
 STRIPING.
 2017 ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES.
 EACH PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL
 BE MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN
 ADJACENT ACCESS AISLE COMPLYING WITH 502.3.
 ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR
 OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT
 MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS.
 WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485
 ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL
 PAINTING.
  
 2) BOTH SHEETS C-100 & SHEET AR1 LIST THE ADDITION OF
 THE FREEZERS AS 458 SQ. FT. IN THE 2017 FBC-B SECTION
 2603.4.1.3 IN NONSPRINKLERED BUILDINGS LIMITS THE
 AGGREGATE FLOOR AREA TO 400 SQ. FT.
 3) SHEET A1.0 IN THE UPPER RIGHT CORNER OF THE SHEET,
 NOTE 11 STATES THERE IS AN OPTION FOR EXTERIOR DOOR
 REPLACEMENT. 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR
 IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC INFORMATION AND OPTIONS.".
 CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITY TO
 INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 4) SHEET A1.2 SHOWS 60 SEATS BUT THE PLAN DOES NOT SHOW
 ANY ACCESSIBLE SEATS. PLEASE SHOW COMPLIANCE WITH:
  
 4A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 4B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES
 REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 4C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN
 RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL
 BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR
 SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 4D) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK
 SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS,
 STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER
 TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORK STATIONS.
  
 4E)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 4E)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 5) SHEET A2.0 LIST SOME OF THE PRODUCT APPROVALS FOR
 WINDOWS AND DOORS BUT IS SILENT TO THE FOLLOWING:
 5A) METAL WALL PANEL SYSTEM (CM)
 5B) ALUMINUM BATTEN SYSTEM (AL)
 5C) APOLIC METAL PANEL (AP)
  
 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, ROOF TOP
 INSULATION, LIGHTWEIGHT CONCRETE INSULATION, ROOF TOP
 VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 6A) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 6C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 7) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 8A) SHEETS A2.1 AND S0.2 BOTH SHOW WALL PRESSURES IN
 VULT, THE NEGATIVE WALL PRESSURES SEAM LOW FOR THE 10
 SQ. FT. AT A MEAN ROOF HEIGHT OF 18 FEET. THE PLANS DO
 NOT INDICATE ANY INTERPOLATION BETWEEN CONTOUR LINES IS
 THIS THE CASE?
  
 8B) PLEASE PROVIDE THE PRESSURES FOUND ON SHEET S0.2 IN
 VASD SINCE BOTH THE MIAMI-DADE NOAS AND FLORIDA
 APPROVALS ARE IN VASD. THE INSPECTORS DO NOT HAVE THE
 TIME TO MULTIPLY THE VULT BY 0.6, SINCE THE APPROVALS
 ARE VASD.
  
 9) WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 10) 109.3* BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL
 TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED
 SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE,
 LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR
 FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE
 REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-09-28 Cont ID  
Sent By fgiaquin Date 2020-09-28 Time 21:59 Rev Time 0.00
Received By fgiaquin Date 2020-09-28 Time 20:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By fgiaquin Date 2020-07-16 Time 20:21 Rev Time 0.00
Received By fgiaquin Date 2020-07-16 Time 19:30 Sent To  
Notes
2020-07-16 20:19:40ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
  
 2. PROVIDE COMPLIANCE FOR THE FOLLOWING, A NOTE ON PLAN
 WILL SUFFICE.
  
 A. EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER
 CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE
 LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY
 OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL
 UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN NEC
 600.6(A)(1)
  
 B. ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 405.1
 SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT
 OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR &
 TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME
 SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING
 DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS.
 FBC-EC 405.2.5
  
 3. THERE ARE SEVERAL OPTIONS ON THIS PLAN I.E. LIGHTING
 NOTE #2, POWER PLAN KEY NOTE #2, POWER PLAN KEY NOTE
 #4, POWER PLAN KEY NOTE #7. PROVIDE NOTE ON PLAN
 STATING IF OPTIONS ARE EXERCISED REVISIONS TO THE PLAN
 WILL BE SUBMITTED TO THE AHJ. FBC 107.4, 107.2.1
  
 4. PROVIDE NOTE ON PLAN STATING LOW VOLTAGE WILL
 REQUIRE A SEPARATE ELECTRICAL PERMIT. FBC 107.2.1 FBC
 105.1
  
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-02-26 Cont ID  
Sent By pleduc Date 2021-02-26 Time   Rev Time 0.00
Received By pleduc Date 2021-02-26 Time 10:51 Sent To  
Notes
2021-02-26 10:59:30SHEET E 1 - COOLER EXIT SIGNS NOT INDICATED
  
  
 FIRE PROVISO:
  
 PROVIDE EXIT SIGNS PER REVISED SHEET A 1.0
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2020-09-14 Cont ID  
Sent By pleduc Date 2020-09-14 Time   Rev Time 0.00
Received By pleduc Date 2020-09-14 Time 11:13 Sent To  
Notes
2020-09-14 11:31:292ND REVIEW COMMENTS
  
  
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 THE COOLER DOORS ARE WITHIN THE MEANS OF EGRESS, THEY
 ARE THE ONLY WAY OUT AND THE TWO INTERIOR DOORS SHALL
 BE IDENTIFIED AND MARKED AS AN EXIT.
  
 BOTH DOORS ARE INDICATED AS # 9.
  
 THE EXTERIOR DOORS MARKED AS 3A AND 9 WOULD NOT BE
 REQUIRED TO BE MARKED AS EXIT.
  
  
  
 THE BELOW PREVIOUS COMMENTS A RE-SUBMITTED:
  
  
 1) SHEET A 1.0 - AT THE OUSIDE OF THE NEW COOLER THERE
 APPEARS TO BE 2 DOORS # 3A AND # 9.
  
 IS THIS DOOR PROPOSED AS AN EXIT DOOR FROM THE COOLER?
 IF SO, PLEASE PROVIDE FOR COMPLAINCE WITH NFPA 101, CH
 7 MEANS OF EGRESS.
  
 BOTH DOORS OPEN OUT AND THERE APPEARS TO BE A DEADBOLT
 ON DOOR 3A (GENERAL NOTES- DOOR 3A # 2)
  
  
  
 2) SHEET E 1 - THERE IS NO INDICATIONS OF EXIT SIGNAGE
 WITHIN THE NEW COOLERS.
  
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-06-09 Cont ID  
Sent By pleduc Date 2020-06-09 Time   Rev Time 0.00
Received By pleduc Date 2020-06-09 Time 09:03 Sent To  
Notes
2020-06-09 15:10:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 1.0 - AT THE OUSIDE OF THE NEW COOLER THERE
 APPEARS TO BE 2 DOORS # 3A AND # 9.
  
 IS THIS DOOR PROPOSED AS AN EXIT DOOR FROM THE COOLER?
 IF SO, PLEASE PROVIDE FOR COMPLAINCE WITH NFPA 101, CH
 7 MEANS OF EGRESS.
  
 BOTH DOORS OPEN OUT AND THERE APPEARS TO BE A DEADBOLT
 ON DOOR 3A (GENERAL NOTES- DOOR 3A # 2)
  
  
 PER NFPA 101, CH 7
  
 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES.
 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED
 READILY FROM
 THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED.
 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY
 TO DOOR
 LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER EXPOSURE TO
 ELEVATED
 TEMPERATURE IN ACCORDANCE WITH THE LISTING, BASED ON
 LABORATORY
 FIRE TEST PROCEDURES.
 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE
 OF A KEY, A
 TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM
 THE EGRESS
 SIDE.
 7.2.1.5.4 THE REQUIREMENTS OF 7.2.1.5.1 AND 7.2.1.5.3
 SHALL NOT
 APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 18 THROUGH
 23.
 7.2.1.5.5 KEY-OPERATED LOCKS.
 7.2.1.5.5.1* EXTERIOR DOOR ASSEMBLIES SHALL BE
 PERMITTED TO HAVE
 KEY-OPERATED LOCKS FROM THE EGRESS SIDE, PROVIDED THAT
 ALL OF THE
 FOLLOWING CRITERIA ARE MET:
 (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11
 THROUGH 43 FOR
 THE SPECIFIC OCCUPANCY.
 (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS
 THAN 1 IN.
 (25 MM) HIGH ON A CONTRASTING BACKGROUND THAT READS AS
 FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF:
 THIS
 DOOR TO REMAIN UNLOCKED WHEN THE
 BUILDING IS OCCUPIED.
 (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY
 DISTINGUISHABLE
 AS LOCKED.
 (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT
 INSIDE THE
 BUILDING WHEN IT IS LOCKED.
  
 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR
 LEAF SHALL
 BE PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS
 METHOD OF
 OPERATION AND THAT IS READILY OPERATED UNDER ALL
 LIGHTING CONDITIONS.
 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH
 SHALL BE
 LOCATED AS FOLLOWS:
 (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED
 FLOOR FOR
 OTHER THAN EXISTING INSTALLATIONS
 (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED
 FLOOR
 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE
 DOOR LEAF
 WITH NOT MORE THAN ONE RELEASING OPERATION, UNLESS
 OTHERWISE
 SPECIFIED IN 7.2.1.5.10.3, 7.2.1.5.10.4, OR
 7.2.1.5.10.6.
  
 PLEASE REVIEW AND PROVIDE DETAILS.
  
  
  
 2) SHEET E 1 - THERE IS NO INDICATIONS OF EXIT SIGNAGE
 WITHIN THE NEW COOLERS.
  
 PER NFPA 101, CH 38 AND CH 7
  
 38.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS
 SHALL HAVE
 SIGNS IN ACCORDANCE WITH SECTION 7.10.
  
 7.10 MARKING OF MEANS OF EGRESS.
 7.10.1 GENERAL.
 7.10.1.1 WHERE REQUIRED. MEANS OF EGRESS SHALL BE
 MARKED IN
 ACCORDANCE WITH SECTION 7.10 WHERE REQUIRED IN CHAPTERS
 11
 THROUGH 43.
 7.10.1.2 EXITS.
 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS
 THAT OBVIOUSLY
 AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED
 BY AN APPROVED
 SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT
 ACCESS.
 7.10.1.2.2* HORIZONTAL COMPONENTS OF THE EGRESS PATH
 WITHIN AN EXIT
 ENCLOSURE SHALL BE MARKED BY APPROVED EXIT OR
 DIRECTIONAL EXIT SIGNS
 WHERE THE CONTINUATION OF THE EGRESS PATH IS NOT
 OBVIOUS.
  
 PLEASE PROVIDE EXIT SIGNS AS APPLICABLE.
  
  
  
  
 3) SHEET E 1 - WITH NO EMERGENCY LIGHTING IN THE NEW
 COOLER, ILLUMINATION OF THE MEANS OF EGRESS IS REQUIRED
 PER NFPA 101, CH 38
  
 WITH NO WINDOWS THE EIXT SIGNS MAY NOT BE SUFFICIENT
 FOR ILLUMINATION PURPOSES.
  
 38.2.8 ILLUMINATION OF MEANS OF EGRESS. MEANS OF EGRESS
 SHALL
 BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8.
  
 7.8.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL BE
 CONTINUOUS DURING THE
 TIME THAT THE CONDITIONS OF OCCUPANCY REQUIRE THAT THE
 MEANS OF EGRESS
 BE AVAILABLE FOR USE, UNLESS OTHERWISE PROVIDED IN
 7.8.1.2.2.
 7.8.1.2.1 ARTIFICIAL LIGHTING SHALL BE EMPLOYED AT SUCH
 LOCATIONS AND FOR
 SUCH PERIODS OF TIME AS ARE NECESSARY TO MAINTAIN THE
 ILLUMINATION TO THE
 MINIMUM CRITERIA VALUES HEREIN SPECIFIED.
 7.8.1.2.2* UNLESS PROHIBITED BY CHAPTERS 11 THROUGH 43,
 AUTOMATIC
 LIGHTING CONTROL DEVICES SHALL BE PERMITTED TO
 TEMPORARILY TURN OFF THE
 ILLUMINATION WITHIN THE MEANS OF EGRESS, PROVIDED THAT
 EACH LIGHTING
 CONTROL DEVICE COMPLIES WITH ALL OF THE FOLLOWING:
 (1) IN NEW INSTALLATIONS, THE LIGHTING CONTROL DEVICE
 IS LISTED.
 (2) THE LIGHTING CONTROL DEVICE IS EQUIPPED TO
 AUTOMATICALLY ENERGIZE
 THE CONTROLLED LIGHTS UPON LOSS OF NORMAL POWER AND IS
 EVALUATED
 FOR THIS PURPOSE.
 (3) ILLUMINATION TIMERS ARE PROVIDED AND ARE SET FOR A
 MINIMUM 15-
 MINUTE DURATION.
 (4) THE LIGHTING CONTROL DEVICE IS ACTIVATED BY ANY
 OCCUPANT
 MOVEMENT IN THE AREA SERVED BY THE LIGHTING UNITS.
 (5) IN NEW INSTALLATIONS, THE LIGHTING CONTROL DEVICE
 IS ACTIVATED BY
 ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM, IF
 PROVIDED.
 (6) THE LIGHTING CONTROL DEVICE DOES NOT TURN OFF ANY
 LIGHTS RELIED UPON
 FOR ACTIVATION OF PHOTOLUMINESCENT EXIT SIGNS OR PATH
 MARKERS.
 (7) THE LIGHTING CONTROL DEVICE DOES NOT TURN OFF ANY
 BATTERY-EQUIPPED
 EMERGENCY LUMINAIRES, UNIT EQUIPMENT, OR EXIT SIGNS.
 7.8.1.2.3* ENERGY-SAVING SENSORS, SWITCHES, TIMERS, OR
 CONTROLLERS SHALL
 BE APPROVED AND SHALL NOT COMPROMISE THE CONTINUITY OF
 ILLUMINATION OF
 THE MEANS OF EGRESS REQUIRED BY 7.8.1.2.
  
 PLEASE PROVIDE.
  
  
  
 4) SHEET E 1 - THERE DOES NOT APPEAR TO BE EXIT SIGNS
 AT THE TWO EXIT DOORS OF THE SEATING AREA.
  
 PER NFPA 101, CH 38 AND CH 7
  
 38.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS
 SHALL HAVE
 SIGNS IN ACCORDANCE WITH SECTION 7.10.
  
 7.10 MARKING OF MEANS OF EGRESS.
 7.10.1 GENERAL.
 7.10.1.1 WHERE REQUIRED. MEANS OF EGRESS SHALL BE
 MARKED IN
 ACCORDANCE WITH SECTION 7.10 WHERE REQUIRED IN CHAPTERS
 11
 THROUGH 43.
 7.10.1.2 EXITS.
 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS
 THAT OBVIOUSLY
 AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED
 BY AN APPROVED
 SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT
 ACCESS.
 7.10.1.2.2* HORIZONTAL COMPONENTS OF THE EGRESS PATH
 WITHIN AN EXIT
 ENCLOSURE SHALL BE MARKED BY APPROVED EXIT OR
 DIRECTIONAL EXIT SIGNS
 WHERE THE CONTINUATION OF THE EGRESS PATH IS NOT
 OBVIOUS.
  
 PLEASE REVIEW AND OR JUSTIFY.
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-03-26 Cont ID  
Sent By lmarchan Date 2021-03-26 Time 15:29 Rev Time 0.00
Received By lmarchan Date 2021-02-24 Time 08:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-28 Cont ID  
Sent By fgiaquin Date 2020-09-28 Time 22:00 Rev Time 0.00
Received By fgiaquin Date 2020-09-10 Time 16:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By fgiaquin Date 2020-07-16 Time 20:23 Rev Time 0.00
Received By fgiaquin Date 2020-06-08 Time 13:49 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-03-30 Cont ID  
Sent By lmarchan Date 2021-03-30 Time 09:28 Rev Time 0.00
Received By lmarchan Date 2020-08-27 Time 15:31 Sent To  
Notes
2021-03-25 15:08:51RECEIPT - MU-2020-33290 - $3273.09 - PAID
2020-08-27 15:31:598/27/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By jwitmer Date 2020-06-16 Time 16:15 Rev Time 0.00
Received By jwitmer Date 2020-06-16 Time 13:03 Sent To  
Notes
2020-06-16 16:15:44IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2021-03-11 Cont ID  
Sent By medwards Date 2021-03-11 Time 06:22 Rev Time 0.00
Received By medwards Date 2021-03-11 Time 06:21 Sent To  
Notes
2021-03-11 06:24:14NO MECHANICAL WORK SHOWN ON THE SUBMITTED PLANS. THE
 WALK IN COOLER AND FREEZER MUST BE SUBMITTED WITH A
 SEPARATE PERMIT AND MECHANICAL REVIEW.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-09-21 Cont ID  
Sent By hmoser Date 2020-09-21 Time 13:27 Rev Time 0.00
Received By hmoser Date 2020-09-21 Time 13:16 Sent To  
Notes
2020-09-21 13:31:09PLAN DENIED NO PLAN SUBMITTED HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-07-13 Cont ID  
Sent By hmoser Date 2020-07-13 Time 08:34 Rev Time 0.00
Received By hmoser Date 2020-07-13 Time 07:52 Sent To  
Notes
2020-07-13 08:45:18NO AIR CONDITIONING PLANS SUBMITTED. WALK IN COOLERS
 AND FREEZERS REQUIRE PLANS AND PERMIT.
 IF COOLERS ARE OUTSIDE OF THE BUILDING WIND LOAD ARE
 REQUIRED.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-03-18 Cont ID  
Sent By ccole Date 2021-03-18 Time 11:26 Rev Time 0.00
Received By ccole Date 2021-03-18 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-03-16 Cont ID  
Sent By ccole Date 2021-03-16 Time 10:35 Rev Time 0.00
Received By ccole Date 2021-03-16 Time 08:47 Sent To  
Notes
2021-03-16 10:37:263RD REVIEW FBC-2017 PLUMBING
 PERMIT- 20041058
 3/16/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS FROM THE 1ST AND 2ND REVIEWS LISTED BELOW HAVE
 NOT BEEN COMPLETELY ADDRESSED. NOTES IN CAPS HAVE BEEN
 ADDED FOR FURTHER CLARIFICATION.
  
 2) AR1 & A1.3: PROVIDE PLUMBING FIXTURE CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.3 FBC P. PROVIDE A SCHEDULE
 INDICATING THE REQUIRED AND PROVIDED PLUMBING FIXTURES
 FOR THE A2 OCCUPANCY. PLEASE NOTE THAT THE PLANS DO NOT
 INDICATE DRINKING FOUNTAINS, OR A SERVICE SINK ARE
 EITHER EXISTING OR PROPOSED. REFER TO SECTION 211.1-
 2113 FBC ACC FOR ACCESSIBLE DRINKING FOUNTAIN
 REQUIREMENTS. SHEETS AR1 & A1.3: PLEASE INCLUDE THE
 REQUIRED SERVICE SINK AND DRINKING FOUNTAIN IN THE
 FIXTURE CALCULATION SCHEDULE. IF THE INTENTION IS TO
 PROVIDE DRINKING WATER TO CUSTOMERS IN A CONTAINER FREE
 OF CHARGE BY REQUEST PER SECTION 410.4 SUBSTITUTION,
 PLEASE PROVIDE A NOTE IN THE SCHEDULE TO SHOW
 COMPLIANCE.
  
 3) A1.3: PROVIDE A WATER RISER DRAWING FOR THE
 RESTROOMS SHOWING PIPE SIZES, LOCATIONS OF SHUTOFF
 VALVES, WATER HAMMER ARRESTORS, BACKFLOW PREVENTERS,
 MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB AMENDMENTS
 TO THE FBC. SHEETS A1.6: WATER HAMMER ARRESTORS ARE
 REQUIRED FOR SUPPLY LINES TO THE WATER CLOSETS.
  
 4) A1.0 & A1.3: PROVIDE A SANITARY ISOMETRIC AND WATER
 RISER DRAWING FOR ALL PLUMBING ALTERATIONS IN THE
 KITCHEN/FOOD AND BEVERAGE PREP AREAS. SEE COMMENT ABOVE
 FOR WATER RISER REQUIREMENTS. SHEET A1.0, A1.6: THE MOP
 SINK DETAIL 1/A.16 IS MISLABELED AS FLOOR DRAIN/SINK
 PLAN. SHOW THE MOP SINK POINT OF CONNECTION TO THE
 GREASE WASTE LINE.
  
 5) A1.0 & A1.3: PROVIDE PLUMBING FLAT LINE DRAWINGS
 SHOWING THE SANITARY AND GREASE WASTE LINE RUNS, THE
 WATER DISTRIBUTION SYSTEM, AND POINTS OF CONNECTION.
 SHOW IN THE RISER AND FLAT LINE DRAWING HOW HOT WATER
 IS BEING SUPPLIED TO THE LAVATORIES, HAND SINK, AND ALL
 OTHER FIXTURES REQUIRING HOT OR TEMPERED WATER- SECTION
 107.2.1 WPB AND SECTION 607.1 FBC P. PLEASE NOTE THAT
 GREASE WASTE CALCULATIONS ARE REQUIRED IF ANY NEW
 FIXTURES ARE TO BE DRAINED INTO THE EXISTING SYSTEM-
 SECTION 1003.3.1. SHEETS A1.3 & A1.6: A REFER TO
 SECTION AND TABLE C404.5.1 FBC ENERGY CONSERVATION. THE
 MAXIMUM 2 FT. PIPING LENGTHS FROM THE SOURCE OF HOT
 WATER TO THE PUBLIC LAVATORIES IS EXCEEDED. PLEASE
 PROVIDE EITHER A RECIRCULATION LINE OR POINT OF USE
 WATER HEATERS AT THE LAV SINKS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-09-15 Cont ID  
Sent By ccole Date 2020-09-15 Time 11:06 Rev Time 0.00
Received By ccole Date 2020-09-15 Time 06:50 Sent To  
Notes
2020-09-15 11:06:552ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20041058
 9/15/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS FROM THE 1ST REVIEW LISTED BELOW HAVE NOT BEEN
 COMPLETELY ADDRESSED. ADDITIONAL NOTES IN CAPS HAVE
 BEEN ADDED TO THOSE COMMENTS- PLEASE COMPLY.
  
 2) AR1 & A1.3: PROVIDE PLUMBING FIXTURE CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.3 FBC P. PROVIDE A SCHEDULE
 INDICATING THE REQUIRED AND PROVIDED PLUMBING FIXTURES
 FOR THE A2 OCCUPANCY. PLEASE NOTE THAT THE PLANS DO NOT
 INDICATE DRINKING FOUNTAINS, OR A SERVICE SINK ARE
 EITHER EXISTING OR PROPOSED. REFER TO SECTION 211.1-
 2113 FBC ACC FOR ACCESSIBLE DRINKING FOUNTAIN
 REQUIREMENTS. SHEETS AR1 & A1.3: PLEASE INCLUDE THE
 REQUIRED SERVICE SINK AND DRINKING FOUNTAIN IN THE
 FIXTURE CALCULATION SCHEDULE. IF THE INTENTION IS TO
 PROVIDE DRINKING WATER TO CUSTOMERS IN A CONTAINER FREE
 OF CHARGE BY REQUEST PER SECTION 410.4 SUBSTITUTION,
 PLEASE PROVIDE A NOTE IN THE SCHEDULE TO SHOW
 COMPLIANCE.
  
 3) A1.3: PROVIDE A WATER RISER DRAWING FOR THE
 RESTROOMS SHOWING PIPE SIZES, LOCATIONS OF SHUTOFF
 VALVES, WATER HAMMER ARRESTORS, BACKFLOW PREVENTERS,
 MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB AMENDMENTS
 TO THE FBC. SHEETS A1.6: WATER HAMMER ARRESTORS ARE
 REQUIRED FOR SUPPLY LINES TO THE WATER CLOSET AUTO
 FLUSH VALVES AND THE URINAL- SECTION 604.9 FBC P.
 PLEASE SHOW THEIR LOCATIONS IN THE WATER DIAGRAMS.
  
 4) A1.0 & A1.3: PROVIDE A SANITARY ISOMETRIC AND WATER
 RISER DRAWING FOR ALL PLUMBING ALTERATIONS IN THE
 KITCHEN/FOOD AND BEVERAGE PREP AREAS. SEE COMMENT ABOVE
 FOR WATER RISER REQUIREMENTS. SHEET A1.0, A1.6: SHOW
 THE BEFORE AND AFTER LOCATIONS OF THE RELOCATED
 HANDSINK AND THE MOP SINK. SHOW A FLAT LINE DRAWING
 THAT SHOWS THE POINT OF CONNECTIONS OF THE DRAINS TO
 THE GREASE WASTE LINE. IT IS NOT CLEAR IF THE MOP SINK
 IS A NEW INSTALLATION OR A REPLACEMENT. PLEASE NOTE
 THAT REVISED GREASE WASTE CALULATIONS MUST PROVIDED FOR
 NEW GREASE WASTE LOADS DRAINING INTO THE SYSTEM-
 SECTION 1003.3 FBC P. PROVIDE A SLAB REPAIR DETAIL-
 SECTION 107.2.1 WPB.
  
 5) A1.0 & A1.3: PROVIDE PLUMBING FLAT LINE DRAWINGS
 SHOWING THE SANITARY AND GREASE WASTE LINE RUNS, THE
 WATER DISTRIBUTION SYSTEM, AND POINTS OF CONNECTION.
 SHOW IN THE RISER AND FLAT LINE DRAWING HOW HOT WATER
 IS BEING SUPPLIED TO THE LAVATORIES, HAND SINK, AND ALL
 OTHER FIXTURES REQUIRING HOT OR TEMPERED WATER- SECTION
 107.2.1 WPB AND SECTION 607.1 FBC P. PLEASE NOTE THAT
 GREASE WASTE CALCULATIONS ARE REQUIRED IF ANY NEW
 FIXTURES ARE TO BE DRAINED INTO THE EXISTING SYSTEM-
 SECTION 1003.3.1. SHEETS A1.3 & A1.6: THE PLANS DO NOT
 SHOW HOW HOT WATER IS BEING SUPPLIED TO THE FIXTURES.
 SHOW THE LOCATION OF THE EXISTING WATER HEATER AND
 PROVIDE A SCOPE OF WORK FOR THE APPLIANCE- EXISTING OR
 TO BE REPLACED? VERIFY THAT THE DISTANCE FROM THE WATER
 HEATER TO THE MOST REMOTE FIXTURE REQUIRING HOT WATER
 DOES NOT EXCEED 50 FT. OR PROVIDE A RECIRCULATION LINE-
 SECTION 607.2 FBC P.
  
 7) A1.3: PROVIDE A PLUMBING FIXTURE AND DEVICE SCHEDULE
 THAT INCLUDES THE RESTROOMS AND KITCHEN AREA- SECTION
 107.2.1 WPB & SECTION 405.9 FBC P. SHEET A1.6: THE MOP
 SINK AND FLOOR DRAIN WERE NOT INCLUDED IN THE SCHEDULE.
 A DEVICE SCHEDULE WAS NOT PROVIDED.
  
 8) A1.3: THE MEN'S TOILET ROOM DOOR SHALL NOT SWING
 INTO THE CLEAR FLOOR SPACE OF THE URINAL PER SECTION-
 603.2.3 FBC ACC. SHEET A1.3: THE PLAN SHOWS NO CHANGE
 TO THE DOOR SWINGING INTO THE CLEAR FLOOR SPACE OF THE
 URINAL.
  
 9) PLEASE PROVIDE A PLUMBING SUB-PERMIT APPLICATION-
 SECTION 105.1 WPB AMENDMENTS TO THE FBC-17.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-07-13 Cont ID  
Sent By ccole Date 2020-07-13 Time 10:16 Rev Time 0.00
Received By ccole Date 2020-07-13 Time 08:33 Sent To  
Notes
2020-07-13 10:17:511ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20041058
 7/13/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET AR1: PROVIDE A LIST OF CURRENT CODES AND
 STANDARDS USED IN THE DESIGN OF THE PROJECT. PLEASE
 NOTE THAT ALL PLANS SHALL BE DESIGNED IN ACCORDANCE
 WITH THE 2017 FLORIDA BUILDING CODES SIXTH EDITION.
 REFERENCES ARE MADE TO THE ADA ON SHEET A1.3. PLEASE
 NOTE THAT THE PLANS SHALL BE IN COMPLIANCE WITH THE
 FBC-17 ACCESSIBILITY CODE. PLEASE REVISE THE REFERENCES
 TO AVOID CONFUSION- SECTION 107.2.1 WPB.
  
 2) AR1 & A1.3: PROVIDE PLUMBING FIXTURE CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.3 FBC P. PROVIDE A SCHEDULE
 INDICATING THE REQUIRED AND PROVIDED PLUMBING FIXTURES
 FOR THE A2 OCCUPANCY. PLEASE NOTE THAT THE PLANS DO NOT
 INDICATE DRINKING FOUNTAINS, OR A SERVICE SINK ARE
 EITHER EXISTING OR PROPOSED. REFER TO SECTION 211.1-
 2113 FBC ACC FOR ACCESSIBLE DRINKING FOUNTAIN
 REQUIREMENTS.
  
 3) A1.3: PROVIDE A WATER RISER DRAWING FOR THE
 RESTROOMS SHOWING PIPE SIZES, LOCATIONS OF SHUTOFF
 VALVES, WATER HAMMER ARRESTORS, BACKFLOW PREVENTERS,
 MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB AMENDMENTS
 TO THE FBC.
  
 4) A1.0 & A1.3: PROVIDE A SANITARY ISOMETRIC AND WATER
 RISER DRAWING FOR ALL PLUMBING ALTERATIONS IN THE
 KITCHEN/FOOD AND BEVERAGE PREP AREAS. SEE COMMENT ABOVE
 FOR WATER RISER REQUIREMENTS.
  
 5) A1.0 & A1.3: PROVIDE PLUMBING FLAT LINE DRAWINGS
 SHOWING THE SANITARY AND GREASE WASTE LINE RUNS, THE
 WATER DISTRIBUTION SYSTEM, AND POINTS OF CONNECTION.
 SHOW IN THE RISER AND FLAT LINE DRAWING HOW HOT WATER
 IS BEING SUPPLIED TO THE LAVATORIES, HAND SINK, AND ALL
 OTHER FIXTURES REQUIRING HOT OR TEMPERED WATER- SECTION
 107.2.1 WPB AND SECTION 607.1 FBC P. PLEASE NOTE THAT
 GREASE WASTE CALCULATIONS ARE REQUIRED IF ANY NEW
 FIXTURES ARE TO BE DRAINED INTO THE EXISTING SYSTEM-
 SECTION 1003.3.1.
  
 6) A1.3: TEMPERED WATER SHALL BE PROVIDED TO THE
 LAVATORY PER SECTION 416.5 FBC P. PLEASE NOTE THAT
 TEMPERED SHALL BE SUPPLIED THROUGH A WATER TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070- SECTION
 607.1.2 FBC P.
  
 7) A1.3: PROVIDE A PLUMBING FIXTURE AND DEVICE SCHEDULE
 THAT INCLUDES THE RESTROOMS AND KITCHEN AREA- SECTION
 107.2.1 WPB & SECTION 405.9 FBC P.
  
 8) A1.3: THE MEN'S TOILET ROOM DOOR SHALL NOT SWING
 INTO THE CLEAR FLOOR SPACE OF THE URINAL PER SECTION-
 603.2.3 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-03-18 Cont ID  
Sent By ccole Date 2021-03-18 Time 12:33 Rev Time 0.00
Received By ccole Date 2021-03-18 Time 12:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-03-16 Cont ID  
Sent By ccole Date 2021-03-16 Time 10:55 Rev Time 0.00
Received By ccole Date 2021-03-16 Time 10:55 Sent To  
Notes
2021-03-16 11:01:37DIGITAL SIGNATURE REVIEW
 3/16/2021
  
 1) SHEETS A1.6 & AR.1 ARE NOT DIGITALLY SIGNED AND
 SEALED BY THE ARCHITECT- FL. STATUTE 481.221 AND
 SECTION 61G1-16.005.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-28 Cont ID  
Sent By fgiaquin Date 2020-09-28 Time 21:59 Rev Time 0.00
Received By fgiaquin Date 2020-09-28 Time 21:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By fgiaquin Date 2020-07-16 Time 20:23 Rev Time 0.00
Received By fgiaquin Date 2020-07-16 Time 20:21 Sent To  
Notes
2020-07-16 20:23:00DIGITAL SIGNATURE FROM PE MUST HAVE VERIFIED DIGITAL
 CERTIFICATE.

Review Stop Z ZONING
Rev No 3 Status P Date 2021-03-26 Cont ID  
Sent By llouie Date 2021-03-26 Time   Rev Time 0.00
Received By llouie Date 2021-03-26 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2020-09-16 Time   Rev Time 0.00
Received By llouie Date 2020-09-16 Time 10:19 Sent To  
Notes
2020-09-16 10:19:51** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) FREEZER STORAGE CALCULATIONS ARE INCONSISTENT IN
 THE SITE PLAN, FLOOR PLAN AND LANDSCAPE PLAN. PLEASE
 ADDRESS FOR CONSISTENCY.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE ANY
 QUESTIONS.
  
 * Z = GC (OUTPARCEL; BELMONT PLAZA)
  
 * PROPOSED SEATING: 63 SEATS (REQUIRED PARKING: 21
 PARKING SPACES)
  
 * PHOTOMETRIC PLAN: USE OF EXISTING POLE FIXTURE
 LOCATION
  
 * RELATED PERMITS: LANDSCAPING (#20070015)
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-10 Cont ID  
Sent By llouie Date 2020-06-10 Time   Rev Time  
Received By llouie Date 2020-06-10 Time   Sent To  
Notes
2020-06-10 10:55:59** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PROVIDE AN UPDATED SIGNED AND SEALED SURVEY OF THE
 PROPERTY. THE SURVEY PROVIDED IS FROM FEBRUARY 2017 AND
 DOES NOT REFLECT THE LATEST CHANGES MADE TO THE SITE.
  
 2.) THE OUTDATED SURVEY SHOWS THAT THE EXISTING
 STRUCTURE IS 4,056 SQ. FT. THE SITE PLAN SHOWS THAT THE
 EXISTING BUILDING IS 3,810 SQ. FT. WITH A PROPOSED 102
 SQ. FT. BUILDING ADDITION. PLEASE CLARIFY THE
 DISCREPANCY.
  
 3.) THE PROPOSED SITE MODIFICATIONS WILL ELIMINATE
 EIGHT (8) EXISTING PARKING SPACES. PLEASE PROVIDE
 ADDITIONAL INFORMATION ON THE RESTAURANT SEATING
 CAPACITY SO THAT REQUIRED PARKING CAN BE CALCULATED.
  
 4.) THE EXISTING PARKING STALL STRIPING IS INCONSISTENT
 WITH THE MINIMUM STRIPING REQUIREMENTS OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS). STRIPING FOR
 THE PROJECT SHALL BE UPDATED FOR CONSISTENCY WITH THE
 CITY?S STANDARDS. A STRIPING DETAIL SHALL ALSO BE
 PROVIDED IN THE DETAILS SHEET TO ENSURE CONSISTENCY
 WITH THE ZONING CODE. [ZLDR S.94-485]
  
 5.) TWO-WAY DRIVE AISLES SHALL BE A MINIMUM OF 24 FT.
 WIDE. [ZLDR S.94-485]
  
 6.) DETAIL OF THE LOCATION OF THE BICYCLE RACKS (WITH
 DIMENSIONS) REQUIRED IN THE DETAILS. BICYCLE RACK
 DIMENSIONS AND SPACING SHALL BE CONSISTENT WITH THE
 CITY?S BICYCLE PARKING DESIGN STANDARDS.
  
 7.) THE VALUE OF THE CONSTRUCTION FROM PERMITS
 TABULATED FOR THE YEAR EXCEEDS 50% OF THE STRUCTURE'S
 VALUE ($546,074.00) ACCORDING TO THE P.B.C. PROPERTY
 APPRAISER'S OFFICE; THEREFORE, PURSUANT TO SECTION
 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY.
  
 NOTES:
  
 * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 SEPARATE PERMITS REQUIRED FOR: BUILDING
 INTERIOR/EXTERIOR IMPROVEMENTS, LANDSCAPING, SIGNAGE,
 PHOTOMETRICS.
  
 * ZONE: GC (OUTPARCEL; BELMONT PLAZA).
  