| Plan Review Stops For Permit 20040979 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-06 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-06 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-05 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2020-08-05 16:41:25 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SOILS REPORT. | | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-22 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-19 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-06-22 08:45:31 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SOILS REPORT. | | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 2. PROVIDE DESIGN PRESSURES FOR NEW WINDOW AND EXT. | | | DOOR OPENINGS. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND EXT. | | | DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-05 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-22 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-19 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-06-22 08:49:02 | PLAN REVIEW - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE NEW PANEL SCHEDULE. IDENTIFY NEW AND | | | EXISTING CIRCUTS. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 2. PROVIDE UPDATED LOAD CALCULATIONS. | | | PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL LOADS | | | FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS FOR | | | THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2. | | | | | | | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
N |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-22 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-22 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2020-06-22 07:57:27 | NO LOW VOLTAGE PLAN PROVIDED. CT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-06 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-06 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-05 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-20 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-22 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-02 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-21 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-08-11 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2020-08-21 14:46:05 | MU-2020-031507 - $393.79 - PAID | | 2020-08-11 11:15:43 | 8/11/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-06-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-19 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-19 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-06-19 15:39:52 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2020-07-29 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2020-07-29 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2020-07-29 08:10:40 | PASS PROVISO | | | REVISION WILL BE REQUIRED ON HOW NEW DUCT IS TIED INTO | | | EXISTING UNIT. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 565-805-6732 | | | FAX 561-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-06-16 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-06-16 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2020-06-16 13:24:41 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20040979 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE SPECS SHEETS AND CALCULATIONS FOR | | | HEATING AND COOLING EQUIPMENT SIZING FOR THIS ADDITION. | | | FBC EC M403.7; FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE | | | MECHANICAL SYSTEM FOR THIS ADDITION. | | | | | | 3) PLEASE PROVIDE THE SPECS. FOR THE EXHAUST FANS. | | | PLEASE SHOW ON PLAN THE EXHAUST DUCT AND TERMINATION | | | POINTS FOR THE BATH EXHAUSTS. | | | | | | 4) PLEASE SHOW AN EXHAUST FAN FOR THE MASTER BATHROOM, | | | SHOWER AREA. FBC M BATHROOM DEFINITION; FBC RES , FBC M | | | TABLE 403.3.1.1; FBC RES TABLE M1507.4 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-06-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-18 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-18 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-05 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-22 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-19 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-06-22 08:39:42 | PLAN REVIEW - ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING SUB PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | | SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-05 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-06-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-06-16 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-06-16 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-06-11 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2020-06-11 |
Time |
|
Sent To |
I |
|
| Notes |
|
|