Plan Review Details - Permit 20040979
Plan Review Stops For Permit 20040979
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-08-06 Cont ID  
Sent By cthroop Date 2020-08-06 Time 12:23 Rev Time 0.00
Received By cthroop Date 2020-08-06 Time 12:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 16:40 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 15:29 Sent To  
Notes
2020-08-05 16:41:25PLAN REVIEW - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SOILS REPORT.
 FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE
 CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE
 REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL
 INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY
 TESTING OR ENGINEERING CALCULATIONS, SUCH
 INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED
 DESIGN PROFESSIONAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-22 Cont ID  
Sent By cthroop Date 2020-06-22 Time 08:39 Rev Time 0.00
Received By cthroop Date 2020-06-19 Time 12:50 Sent To  
Notes
2020-06-22 08:45:31PLAN REVIEW - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SOILS REPORT.
 FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE
 CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE
 REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL
 INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY
 TESTING OR ENGINEERING CALCULATIONS, SUCH
 INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED
 DESIGN PROFESSIONAL.
  
 2. PROVIDE DESIGN PRESSURES FOR NEW WINDOW AND EXT.
 DOOR OPENINGS.
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 3. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND EXT.
 DOORS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 16:40 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 15:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-22 Cont ID  
Sent By cthroop Date 2020-06-22 Time 08:45 Rev Time 0.00
Received By cthroop Date 2020-06-19 Time 12:50 Sent To  
Notes
2020-06-22 08:49:02PLAN REVIEW - ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE NEW PANEL SCHEDULE. IDENTIFY NEW AND
 EXISTING CIRCUTS.
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
  
 2. PROVIDE UPDATED LOAD CALCULATIONS.
 PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL LOADS
 FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS FOR
 THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2.
  
  
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status N Date 2020-06-22 Cont ID  
Sent By cthroop Date 2020-06-22 Time 07:56 Rev Time 0.00
Received By cthroop Date 2020-06-22 Time 07:56 Sent To  
Notes
2020-06-22 07:57:27NO LOW VOLTAGE PLAN PROVIDED. CT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-08-06 Cont ID  
Sent By cthroop Date 2020-08-06 Time 12:23 Rev Time 0.00
Received By cthroop Date 2020-08-06 Time 12:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 16:41 Rev Time 0.00
Received By cthroop Date 2020-07-20 Time 10:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-22 Cont ID  
Sent By cthroop Date 2020-06-22 Time 08:45 Rev Time 0.00
Received By cthroop Date 2020-06-02 Time 10:57 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-08-21 Cont ID  
Sent By lmarchan Date 2020-08-21 Time 15:01 Rev Time 0.00
Received By lmarchan Date 2020-08-11 Time 11:15 Sent To  
Notes
2020-08-21 14:46:05MU-2020-031507 - $393.79 - PAID
2020-08-11 11:15:438/11/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-06-19 Cont ID  
Sent By cthroop Date 2020-06-19 Time 15:39 Rev Time 0.00
Received By cthroop Date 2020-06-19 Time 12:50 Sent To  
Notes
2020-06-19 15:39:52IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-07-29 Cont ID  
Sent By hmoser Date 2020-07-29 Time 08:10 Rev Time 0.00
Received By hmoser Date 2020-07-29 Time 06:52 Sent To  
Notes
2020-07-29 08:10:40PASS PROVISO
 REVISION WILL BE REQUIRED ON HOW NEW DUCT IS TIED INTO
 EXISTING UNIT.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 565-805-6732
 FAX 561-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By medwards Date 2020-06-16 Time 13:24 Rev Time 0.00
Received By medwards Date 2020-06-16 Time 11:21 Sent To  
Notes
2020-06-16 13:24:411ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20040979
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE SPECS SHEETS AND CALCULATIONS FOR
 HEATING AND COOLING EQUIPMENT SIZING FOR THIS ADDITION.
 FBC EC M403.7; FBC EC 101.5.1.1.2
  
 2) PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE
 MECHANICAL SYSTEM FOR THIS ADDITION.
  
 3) PLEASE PROVIDE THE SPECS. FOR THE EXHAUST FANS.
 PLEASE SHOW ON PLAN THE EXHAUST DUCT AND TERMINATION
 POINTS FOR THE BATH EXHAUSTS.
  
 4) PLEASE SHOW AN EXHAUST FAN FOR THE MASTER BATHROOM,
 SHOWER AREA. FBC M BATHROOM DEFINITION; FBC RES , FBC M
 TABLE 403.3.1.1; FBC RES TABLE M1507.4
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-06-18 Cont ID  
Sent By cthroop Date 2020-06-18 Time 15:53 Rev Time 0.00
Received By cthroop Date 2020-06-18 Time 15:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 16:30 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 15:29 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-06-22 Cont ID  
Sent By cthroop Date 2020-06-22 Time 08:33 Rev Time 0.00
Received By cthroop Date 2020-06-19 Time 12:50 Sent To  
Notes
2020-06-22 08:39:42PLAN REVIEW - ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING SUB PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING
 SYSTEM COMPONENTS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 16:40 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 15:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-06-16 Cont ID  
Sent By medwards Date 2020-06-16 Time 13:33 Rev Time 0.00
Received By medwards Date 2020-06-16 Time 13:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By kalexand Date 2020-06-11 Time   Rev Time  
Received By   Date 2020-06-11 Time   Sent To I
Notes
***NONE***