| 2020-07-08 07:13:14 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 20040922 5503 N FLAGLER DR |
| | |
| | 2ND REVIEW |
| | |
| | GAS COMMENTS: DENIED |
| | A PLUMBING PERMIT AND PLAN APPEARS TO BE REQUIRED FOR A |
| | COMPLETE INSTALLATION. PLEASE PROVIDE A PERMIT |
| | APPLICATION NUMBER INDICATING THE REQUIRED PLUMBING |
| | WORK. |
| | THE TANKLESS WATER HEATER REQUIRES 120V ELECTRIC FOR |
| | IGNITION. AN ELECTRICAL PERMIT AND PLAN IS REQUIRED FOR |
| | ANY NEW ELECTRICAL WORK. |
| | |
| | 1. PLEASE HAVE A SIGNATURE ON THE HOUSE PLAN #14 AS |
| | WELL AS THE ISOMETRIC DRAWING BY THE PERSON DESIGNING |
| | THE SYSTEM, PER FAC 61G15-23.001, FS 471 PER WPB FBC |
| | 107.2.1. |
| | 2. REGARDING HOUSE PLAN #14, PER WPB FBC 107.2.1, SHOW |
| | LOCATION OF THE METER. SHOW VERTICAL AND HORIZONTAL |
| | ROUTING OF PIPE FROM METER TO THE TANKLESS WATER |
| | HEATER. INDICATE UNDERGROUND PIPING. |
| | 3. NEW COMMENT: PER WPB FBC 107.2.1, SUBMIT |
| | MANUFACTURER, MANUFACTURER?S SPECIFICATION AND |
| | INSTALLATION GUIDE FOR CSST TUBING. VERTICAL PIPING AT |
| | EXTERIOR WALL AND AT METER IS INDICATED AS CSST. IS |
| | THIS PIPING EXPOSED ON THE EXTERIOR? CLARIFY. PROVIDE |
| | PROTECTION OF PIPING AS REQUIRED IN THE MANUFACTURER?S |
| | INSTALLATION GUIDE OR SPECIFY AND INSTALL SCHEDULE 40 |
| | STEEL PIPE FOR THE EXPOSED VERTICAL PIPING AND PROVIDE |
| | TABLE FOR THE SAME. MANUFACTURER?S INSTALLATION GUIDE |
| | SHALL BE ON SITE FOR ALL INSPECTIONS. |
| | 4. RESPONSE LETTER STATES THIS IS A 2PSI SYSTEM. THE |
| | REGULATOR DOWNSTREAM OF THE METER ACCORDING TO |
| | SUBMITTAL IS A MP REGULATOR GOING FROM 2 PSI TO LESS |
| | THAN 2PSI. PER WPB FBC 107.2.1, INDICATE ON THE PLAN ON |
| | THE PLAN THE SYSTEM THAT IS 2PSI AND THE PORTION WHICH |
| | IS LESS THAN 2 PSI. PROVIDE MATERIAL SPEC FOR 2PSI |
| | PIPING, MAXIMUM LENGTH OF 2 PSI FROM METER TO |
| | REGULATOR, TABLE AND SIZING. |
| | 5. REGARDING ISOMETRIC DRAWING, THE PVC SLEEVE TURNS UP |
| | AND IS VENTED AT THE METER LOCATION. AT THE HOUSE IT |
| | APPEARS TO DEAD END HORIZONTALLY. PER WPB FBC 107.2.1, |
| | CLARIFY. |
| | 6. REGARDING ISOMETRIC DRAWING, A LISTED SHUTOFF VALVE |
| | SHALL BE INSTALLED AHEAD OF, NOT DOWNSTREAM OF THE MP |
| | REGULATOR PER FBC RES G2420.4 |
| | 7. PER WPB FBC 107.2.1, RESUBMIT MANUFACTURER?S |
| | SPECIFICATION FOR THE TANKLESS WATER HEATER. IDENTIFY |
| | ON THE MANUFACTURER?S SPECIFICATION THE MANUFACTURER?S |
| | MODEL NUMBER OF THE UNIT BEING PROVIDED. MANUFACTURER?S |
| | SPECIFICATION SHALL BE ON SITE FOR INSPECTION. GAS |
| | APPLIANCE SHALL BE LISTED AND LABELED. THE INSTALLATION |
| | MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT SHALL BE |
| | ONSITE AT THE TIME OF INSPECTION PER THE 2017 FBC RES. |
| | SEC. G2413.2 AND G2404.3. |
| | 8. PLEASE PROVIDE AN UPDATED TABLE, TWO COPIES OF THE |
| | SIZING TABLES USED IN THE DESIGN FOR THE GAS SYSTEM OR |
| | PLACE A NOTE ON BOTH SETS OF PLANS LISTING THE SIZING |
| | TABLES FROM GAS CODES OR ANOTHER STANDARD THAT WERE |
| | USED IN THE DESIGN OF THIS SYSTEM PER THE 2017 FBC RES. |
| | SEC. G2413.3. TO BE CLEAR, THIS APPLIES TO 2PSI AND |
| | LESS THAN 2PSI AND FOR EACH MATERIAL |
| | 9. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE |
| | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION |
| | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN |
| | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER |
| | HEATER SHALL COMPLY WITH THE MANUFACTURER'S |
| | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE |
| | HAND-DRAWN PER THE WPB AMENDMENTS TO THE FBC SEC. |
| | 107.2.1. INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | 10. TO BE CLEAR, TANKLESS HOT WATER PIPING, NOT |
| | TANKLESS WATER HEATER, MUST BE INSULATED WITH A MINIMUM |
| | R-3 PER THE 2017 FBC RE 403.5.3, PLEASE PUT A NOTE ON |
| | PLANS. |
| | |
| | END OF COMMENTS. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS |
| | REQUIRED BY FAC AND FS. |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-246-0882 MOBILE |
| | |
| | 20040922 5503 N FLAGLER DR |
| | |
| | |
| 2020-07-07 11:14:36 | JERALD SMITH |