| Plan Review Stops For Permit 20040848 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-07-23 |
Time |
22:32 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-07-23 |
Time |
21:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-17 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-17 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2020-06-17 12:18:19 | SEE COMMENTS FROM LAST REVIEW NONE OF THE COMMENTS HAVE | | | BEEN ADDRESSED. JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-14 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-05-14 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2020-05-14 12:08:59 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | YOU HAVE PAPER WORK SHOWING AN APPLICATION AND OTHER | | | PAPERWORK FOR BROWARD COUNTY, PLEASE REMOVE. | | | | | | PLEASE SUBMIT A SIGNED CONTRACGT FOR THE SYSTEM. VALUE | | | QUOTED IS BELOW NATIONAL STANDARDS. | | | | | | NEED TO HAVE AN ELECTRICAL PERMIT FOR THE TIE INTO THE | | | SYSTEM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-04-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-23 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-23 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2020-04-23 10:43:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLANS PROVIDED AND SUPPLEMENTAL DOCUMENTS, EXCEPT | | | FOR PERMIT APPLICATION, ARE ALL FOR A PROJECT IN | | | HOLLYWOOD, FL. PROVIDE PLANS FOR THE RIGHT PROJECT. | | | REMOVE ANY PAPERWORK DEALING WITH PERMITTING IN | | | HOLLYWOOD, FL. WPB FBC 107.2.1 | | | 2. THE PLAN PROVIDED DETAILS A SYSTEM WITH AN OUTPUT OF | | | 10.54 KW, WHICH EXCEEDS THE AMOUNT ALLOWED TO BE | | | SUBMITTED FOR EXPEDITED REVIEW. IF THE ACTUAL SYSTEM | | | DETAILED ON THE RIGHT PLANS FOR THIS JOB ALSO EXCEED 10 | | | KW, THIS REVIEW WILL BE REJECTED AND PUT THROUGH THE | | | NORMAL REVIEW PROCESS. PLEASE CLARIFIY. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-07-23 |
Time |
22:32 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-07-16 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-17 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-05-26 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-14 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-04-23 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-04-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-22 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-07-23 |
Time |
22:25 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-07-23 |
Time |
22:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-17 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-17 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-14 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-05-14 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-04-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-23 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-23 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2020-04-23 10:39:01 | SIGNATURES WERE ALL GOOD, BUT SUPPLIED FOR THE WRONG | | | ADDRESS. ANY NEW SHEETS SUBMITTED WILL NEED TO BE | | | CHECKED FOR DIGITAL SIGNATURE WITH PROPER THIRD-PARTY | | | VERIFICATION. WPB FBC 105.1; FS 471/481 |
|
|