2020-06-01 11:19:23 
 RESIDENTIAL (R3) THIRD BUILDING REVIEW CHECKLIST
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- OK.
  
 2- WINDOW FLORIDA PRODUCT APPROVAL SUBMITTED IS FORR
 NON-IMPACT IMPACTS. NEED TO PROVIDE GLAZING IMPACT
 PROTECTION AS REQUIRED BY SEC. 702.6 FBC-EXISTING
 BUILDING AND SEC. R301.2.1.2 FBC-RESIDENTIAL.
 NEED TO PROVIDE PRODUCT APPROVAL FOR SHUTTERS TO BE
 USED. ALSO, NEED TO PROVIDE SHUTTERS COMPLETE
 INSTALLATION SCHEDULE AS REQUIRED BY CITY
 IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT
 PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY
 SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 RESPONSE:
 SEE SEE ATTACHED RELINED COMMENTS ON THE SHUTTERS
 INSTALLATION SCHEDULE SUBMITTED. NEED TO REVISE THE
 MOUNTING CONDITIONS, SHUTTER SPAN, SHUTTERS
 INSTALLATION (VERTICAL NOT HORIZONTAL) AND ANCHOR TYPE
 AND SPACING. ALSO, PROVIDE A CLEAR/;LEGIBLE COPY.
 PLEASE CAL ME TO GO OVER THEM TO EXPEDITE THE REVIEW
 PROCESS.
  
  
 3- OK.
  
 4- OK.
  
 5- NEED PRODUCT APPROVAL FO FIXED WINDOW IN THE LIVING
 ROOM. SEC. 61G20.3.001 FAC.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-05-11 Cont ID  
Sent By jgomez Date 2020-05-11 Time 10:45 Rev Time 0.00
Received By jgomez Date 2020-05-11 Time 09:53 Sent To  
Notes
2020-05-11 11:31:09 
 RESIDENTIAL (R3) SECOND BUILDING REVIEW CHECKLIST
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- OK.
  
 2- WINDOW FLORIDA PRODUCT APPROVAL SUBMITTED IS FOR
 NON-IMPACT IMPACTS. NEED TO PROVIDE GLAZING IMPACT
 PROTECTION AS REQUIRED BY SEC. 702.6 FBC-EXISTING
 BUILDING AND SEC. R301.2.1.2 FBC-RESIDENTIAL.
 NEED TO PROVIDE PRODUCT APPROVAL FOR SHUTTERS TO BE
 USED. ALSO, NEED TO PROVIDE SHUTTERS COMPLETE
 INSTALLATION SCHEDULE AS REQUIRED BY CITY
 IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT
 PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY
 SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 RESPONSE:
 THERE ARE TWO OPTIONS:
 A) PROVIDE SHUTTERS CURRENT PRODUCT APPROVAL AND
 COMPLETE INSTALLATION SCHEDULE OR
 B) IF USING THE EXISTING HURRICANE SHUTTERS FOR IMPACT
 PROTECTION, THEN THEY NEED TO MEET THE CODE
 REQUIREMENTS OF SEC. R301.2.1.2 FBC-RESIDENTIAL. NOTE:
 NEED ENGINEERING PRODUCT APPROVAL EVALUATION REPORT AND
 TESTING AS REQUIRED BY SEC. R301.2.1.2 FBC-RESIDENTIAL.
  
  
 3- OK.
  
 4- NEED TO UPDATE THE VALUATION TO INCLUDE THE
 INSTALLATION OF HURRICANE SHUTTERS. SEC. 109.3 CITY
 AMENDMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-27 Cont ID  
Sent By jgomez Date 2020-04-27 Time 11:12 Rev Time 0.00
Received By jgomez Date 2020-04-27 Time 11:12 Sent To  
Notes
2020-04-27 11:27:00RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
  
 1-- PROVIDE SKETCH SHOWING ALL WINDOWS TO BE REPLACED.
 CLEARLY IDENTIFY ALL ROOMS ON THE SKETCH PROVIDED. AND
 CLEARLY SPECIFY TYPE AND SIZE OF EXISTING WINDOWS AND
 TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE
 WITH THE BEDROOM EGRESS REQUIREMENTS OF SEC. 702.5
 FBC-EXISTING BUILDING.
  
 2- WINDOW FLORIDA PRODUCT APPROVAL SUBMITTED IS FOR
 NON-IMPACT IMPACTS. NEED TO PROVIDE GLAZING IMPACT
 PROTECTION AS REQUIRED BY SEC. 702.6 FBC-EXISTING
 BUILDING AND SEC. R301.2.1.2 FBC-RESIDENTIAL.
 NEED TO PROVIDE PRODUCT APPROVAL FOR SHUTTERS TO BE
 USED. ALSO, NEED TO PROVIDE SHUTTERS COMPLETE
 INSTALLATION SCHEDULE AS REQUIRED BY CITY
 IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT
 PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY
 SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 3- WINDOW FLORIDA PRODUCT APPROVAL SUBMITTED IS
 INCOMPLETE. NEED TO PROVIDE COMPLETE FLORIDA PRODUCT
 APPROVAL, INCLUDING THE FLORIDA PRODUCT APPROVAL COVER
 PAGE THAT CORRESPONDS TO THE DRAWINGS SUBMITTED. THE
 FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS
 IF PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT.
 CHAPTER 553 F.S.
  
 4- NEED TO UPDATE THE VALUATION TO INCLUDE THE
 INSTALLATION OF HURRICANE SHUTTERS. SEC. 109.3 CITY
 AMENDMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-06-01 Cont ID  
Sent By jgomez Date 2020-06-01 Time 17:41 Rev Time 0.00
Received By jgomez Date 2020-06-01 Time 17:02 Sent To I
Notes
2020-06-01 17:02:31RECEIVED E-MAIL FROM CONTRACTOR. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-06-01 Cont ID  
Sent By jgomez Date 2020-06-01 Time 11:19 Rev Time 0.00
Received By jgomez Date 2020-06-01 Time 10:04 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-11 Cont ID  
Sent By jgomez Date 2020-05-11 Time 11:31 Rev Time 0.00
Received By jgomez Date 2020-05-08 Time 15:56 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-27 Cont ID  
Sent By jgomez Date 2020-04-27 Time 11:27 Rev Time 0.00
Received By jgomez Date 2020-04-17 Time 13:51 Sent To I
Notes
2020-04-23 13:52:41SENT TO UNDER $5000 SHELF FOR REVIEW. JG.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved