| 2020-05-20 10:35:37 | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT #20040734 |
| | 5/20/20 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) FAIR HOUSING ACCESSIBILITY GUIDELINES: DUE TO THE |
| | FACT THAT THE BUILDING WAS CONSTRUCTED IN ACCORDANCE |
| | WITH THE ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING |
| | ACT AND THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN |
| | DWELLING UNITS, THE ALTERATIONS THAT ARE PROPOSED IN |
| | THE BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR |
| | HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES |
| | ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017 |
| | SIXTH EDITION. COMPLIANCE WITH THE GUIDELINES REQUIRES |
| | THAT CLEAR FLOOR SPACES FOR WHEELCHAIR APPROACHES TO |
| | BATH FIXTURES SHALL EITHER BE MAINTAINED AS ORIGINALLY |
| | DESIGNED OR PROVIDED WHERE NEW FIXTURES ARE BEING |
| | INSTALLED. NEW FIXTURES IN THE PROPOSED ALTERATION ARE |
| | THE TWO SHOWERS AND THE SECOND LAVATORY IN THE MASTER |
| | BATH. ADDITIONALLY, REINFORCEMENTS SHALL ALSO BE |
| | INSTALLED IN THE SHOWER WALLS TO SUPPORT FUTURE GRAB |
| | BARS AND OPTIONAL WALL HUNG BENCH SEATS. PLEASE SEE |
| | REQUIREMENT 7 CONTAINED IN THE GUIDELINES AND FIGURES |
| | 5, 7A, 7C, & 7D. PROVIDE ENLARGED DIMENSIONED FLOOR |
| | PLAN DRAWINGS OF THE BATHROOMS SHOWING THE REQUIRED |
| | CLEAR FLOOR SPACES, AND DIMENSIONED ELEVATION VIEWS |
| | SHOWING THE LOCATIONS OF THE WALL REINFORCEMENTS. |
| | 1A) AS AN ALTERNATIVE TO MEETING THE GUIDELINES FOR THE |
| | BATH ALTERATIONS, THE OWNER AND DESIGNER OF RECORD FOR |
| | THE PROPOSED PROJECT MAY PROVIDE A SIGNED AND NOTARIZED |
| | AFFIDAVIT WHICH WOULD INDICATE EACH PERSON ACKNOWLEDGES |
| | THAT THE PROPOSED DESIGN DOES NOT MEET THE REQUIREMENTS |
| | OF THE FAIR HOUSING ACCESSIBILITY GUIDELINES, BUT AS A |
| | CONDITION OF THE ACKNOWLEDGEMENT, THE OWNER AGREES TO |
| | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF |
| | SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, |
| | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A |
| | COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS |
| | OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL |
| | THE SHOWER WALL REINFORCEMENTS. |
| | |
| | 2) SHEET A102: A) REFER TO SECTION 1002.1 FBC P: THE |
| | HORIZONTAL DISTANCE FROM THE CENTERLINE OF THE NEW |
| | SHOWER DRAIN OUTLETS TO THE CENTERLINES OF THE INLETS |
| | OF THE EXISTING TRAPS SHALL NOT EXCEED 30". PLEASE |
| | PLACE A NOTE ON THE PLAN INDICATING COMPLIANCE. B) |
| | PLEASE WRITE THE PLAN SHEET NUMBER (A102) ON THE PLAN- |
| | SECTION 107.2.1 WPB. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |