Plan Review Details - Permit 20040734
Plan Review Stops For Permit 20040734
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-05-17 Cont ID  
Sent By jwitmer Date 2020-05-17 Time 07:13 Rev Time 0.00
Received By jwitmer Date 2020-05-17 Time 06:59 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By jwitmer Date 2020-04-21 Time 10:57 Rev Time 0.00
Received By jwitmer Date 2020-04-21 Time 10:35 Sent To  
Notes
2020-04-21 10:56:59PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date   Cont ID  
Sent By   Date   Time 09:45 Rev Time 0.00
Received By jwitmer Date 2020-05-31 Time 09:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-05-17 Cont ID  
Sent By jwitmer Date 2020-05-17 Time 07:12 Rev Time 0.00
Received By jwitmer Date 2020-05-17 Time 06:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By jwitmer Date 2020-04-21 Time 10:55 Rev Time 0.00
Received By jwitmer Date 2020-04-21 Time 10:33 Sent To  
Notes
2020-04-21 10:55:342017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20040734
 ADD: 630 SAPODILLA AVE. SUITE: 206
 CONT: FLORIDA ALLIED CONTRACTOR SERVICES
 TEL: 239-410-2276
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. APRIL 21/ 2020
 ACTION: DENIED
  
 1) SHEET 2 THE PROPOSED FLOOR PLAN INDICATES THE NEW
 SHOWER FLOOR DRAIN TO BE MOVED FROM THE PRESENT
 LOCATION OF THE TUB. CONTRACTOR WILL NEED TO HAVE THE
 FLOOR X-RAYED TO SEE WHERE THE TENDONS IF POST STRESSED
 FLOOR OR FOR RE-ENFORCING STEEL BARS IN THE FLOOR SLAB.
 PLEASE NOTE ON PLANS BEFORE PERMIT CAN BE ISSUED.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) SINCE THERE IS GOING TO BE A NEW FLOOR PENETRATION
 PLEASE PROVIDE DOCUMENTATION FOR (1) FOR THE OLD FLOOR
 OPENING & (2) THE NEW FLOOR OPENING WITH DRAIN LINE,
 HOW COMPLIANCE WITH SECTION 714.4.1.2. THROUGH-
 PENETRATION FIRESTOP SYSTEMS OF THE 2017 FBC-B ARE TO
 BE COMPLIED.
  
 3) THE PLANS DO NOT ADDRESS THE TILE BACKING IN THE 2
 NEW SHOWERS. PLEASE PROVIDE THE TYPE OF GYPSUM PRODUCT
 WILL BE INSTALLED FOR THE BACKING/ WALL FOR THE TILE.
 IN THE 2017 FBC-B SECTION 2509.2 DOES NOT ALLOW THE USE
 OF MR BOARD IN SHOWERS. PLEASE IDENTIFY THE BASE FOR
 TILE.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2020-05-26 Cont ID  
Sent By jleahy Date 2020-05-26 Time 09:29 Rev Time 0.00
Received By jleahy Date 2020-05-26 Time 09:29 Sent To  
Notes
2020-05-26 09:29:49NO ELECTRIC SHOWN NOT SURE IF IT IS NEEDED. JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-05-04 Cont ID  
Sent By jleahy Date 2020-05-04 Time 08:52 Rev Time 0.00
Received By jleahy Date 2020-05-04 Time 08:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-05-29 Cont ID  
Sent By pleduc Date 2020-05-29 Time   Rev Time 0.00
Received By pleduc Date 2020-05-29 Time 10:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-05-12 Cont ID  
Sent By pleduc Date 2020-05-12 Time   Rev Time 0.00
Received By pleduc Date 2020-05-12 Time 13:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-04-21 Cont ID  
Sent By pleduc Date 2020-04-21 Time   Rev Time 0.00
Received By pleduc Date 2020-04-20 Time 14:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-06-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-05-28 Time 08:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-26 Cont ID  
Sent By jleahy Date 2020-05-26 Time 09:31 Rev Time 0.00
Received By jleahy Date 2020-05-11 Time 08:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-05-07 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-17 Time 08:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-06-02 Cont ID  
Sent By ccole Date 2020-06-02 Time 13:15 Rev Time 0.00
Received By ccole Date 2020-06-02 Time 12:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-05-20 Cont ID  
Sent By ccole Date 2020-05-20 Time 10:27 Rev Time 0.00
Received By ccole Date 2020-05-19 Time 14:34 Sent To  
Notes
2020-05-20 10:35:372ND REVIEW FBC-2017 PLUMBING
 PERMIT #20040734
 5/20/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FAIR HOUSING ACCESSIBILITY GUIDELINES: DUE TO THE
 FACT THAT THE BUILDING WAS CONSTRUCTED IN ACCORDANCE
 WITH THE ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING
 ACT AND THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN
 DWELLING UNITS, THE ALTERATIONS THAT ARE PROPOSED IN
 THE BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. COMPLIANCE WITH THE GUIDELINES REQUIRES
 THAT CLEAR FLOOR SPACES FOR WHEELCHAIR APPROACHES TO
 BATH FIXTURES SHALL EITHER BE MAINTAINED AS ORIGINALLY
 DESIGNED OR PROVIDED WHERE NEW FIXTURES ARE BEING
 INSTALLED. NEW FIXTURES IN THE PROPOSED ALTERATION ARE
 THE TWO SHOWERS AND THE SECOND LAVATORY IN THE MASTER
 BATH. ADDITIONALLY, REINFORCEMENTS SHALL ALSO BE
 INSTALLED IN THE SHOWER WALLS TO SUPPORT FUTURE GRAB
 BARS AND OPTIONAL WALL HUNG BENCH SEATS. PLEASE SEE
 REQUIREMENT 7 CONTAINED IN THE GUIDELINES AND FIGURES
 5, 7A, 7C, & 7D. PROVIDE ENLARGED DIMENSIONED FLOOR
 PLAN DRAWINGS OF THE BATHROOMS SHOWING THE REQUIRED
 CLEAR FLOOR SPACES, AND DIMENSIONED ELEVATION VIEWS
 SHOWING THE LOCATIONS OF THE WALL REINFORCEMENTS.
 1A) AS AN ALTERNATIVE TO MEETING THE GUIDELINES FOR THE
 BATH ALTERATIONS, THE OWNER AND DESIGNER OF RECORD FOR
 THE PROPOSED PROJECT MAY PROVIDE A SIGNED AND NOTARIZED
 AFFIDAVIT WHICH WOULD INDICATE EACH PERSON ACKNOWLEDGES
 THAT THE PROPOSED DESIGN DOES NOT MEET THE REQUIREMENTS
 OF THE FAIR HOUSING ACCESSIBILITY GUIDELINES, BUT AS A
 CONDITION OF THE ACKNOWLEDGEMENT, THE OWNER AGREES TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 2) SHEET A102: A) REFER TO SECTION 1002.1 FBC P: THE
 HORIZONTAL DISTANCE FROM THE CENTERLINE OF THE NEW
 SHOWER DRAIN OUTLETS TO THE CENTERLINES OF THE INLETS
 OF THE EXISTING TRAPS SHALL NOT EXCEED 30". PLEASE
 PLACE A NOTE ON THE PLAN INDICATING COMPLIANCE. B)
 PLEASE WRITE THE PLAN SHEET NUMBER (A102) ON THE PLAN-
 SECTION 107.2.1 WPB.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-05-07 Cont ID  
Sent By ccole Date 2020-05-07 Time 13:06 Rev Time 0.00
Received By ccole Date 2020-05-07 Time 07:46 Sent To  
Notes
2020-05-07 13:10:531ST REVIEW FBC-2017 PLUMBING
 PERMIT #20040734
 5/7/2020
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE REFER TO THE BUILDING PLAN REVIEW COMMENTS #1
 AND 2 REQUIRING FLOOR X-RAY AND PIPE PENETRATION
 FIRESTOPPING. THE PLUMBING PLANS WILL BE APPROVED WHEN
 THESE ISSUES ARE ADDRESSED- SECTION 107.2.1 WPB.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-06-01 Cont ID  
Sent By shill Date 2020-06-01 Time 14:59 Rev Time 0.00
Received By shill Date 2020-06-01 Time 14:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-05-26 Cont ID  
Sent By jleahy Date 2020-05-26 Time 09:31 Rev Time 0.00
Received By jleahy Date 2020-05-26 Time 09:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By jwitmer Date 2020-04-21 Time 10:57 Rev Time 0.00
Received By jwitmer Date 2020-04-21 Time 10:34 Sent To  
Notes
2020-04-21 10:57:52CERTIFICATION BY CONTRACTOR. THE CONTRACTOR (QUALIFIER)
 THAT CREATED / DRAWN THE SET OF PLANS WILL NEED TO
 IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE
 PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR
 THE TRADE YOU ARE LICENSED IN AND PLANS DRAWN.
 107.3.4.3 CERTIFICATION BY CONTRACTOR.