Plan Review Details - Permit 20040688
Plan Review Stops For Permit 20040688
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-06-11 Cont ID  
Sent By jpearson Date 2020-06-11 Time 13:56 Rev Time 0.00
Received By jpearson Date 2020-06-11 Time 07:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-05-07 Cont ID  
Sent By jpearson Date 2020-05-07 Time 10:40 Rev Time 0.00
Received By jpearson Date 2020-05-07 Time 07:25 Sent To  
Notes
2020-05-07 09:55:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AN OWNER BUILDER PERMIT CANNOT BE OBTAINED BY A
 CORPORATION. PROVIDED ELECTRICAL PERMIT APPLICATION
 FROM AN ELECTRICAL CONTRACTOR. WPB FBC 105.1
 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. WPB
 FBC 109.3
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10
 4. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9
 5. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220
 6. PROVIDE THE REQUIRED SERVICE AREA RECEPTACLE PER
 CODE. NEC 210.64
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-06-11 Time   Rev Time 0.00
Received By lmarchan Date 2020-05-29 Time 13:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-05-07 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-21 Time 14:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-06-11 Cont ID  
Sent By jpearson Date 2020-06-11 Time 07:42 Rev Time 0.00
Received By jpearson Date 2020-06-11 Time 07:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-07 Cont ID  
Sent By jpearson Date 2020-05-07 Time 08:57 Rev Time 0.00
Received By jpearson Date 2020-05-07 Time 08:57 Sent To  
Notes
2020-05-07 10:41:36ANY NEW SUBMISSIONS WILL NEED TO BE CHECKED. WPB FBC
 105.1