Plan Review Details - Permit 20040677
| Plan Review Stops For Permit 20040677 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2020-04-29 16:49:49 | PLAN REVIEW - BUILDING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? BUILDING - PX3169 | | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. | | | | | | VALUATION HAS BEEN CHANGED FROM $18,000.00 TO | | | $69,000.00 BASED ON THE ICC BUILDING VALUATION TABLES. | | | | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. PROVIDE SOILS REPORT. | | | | | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 3. PROVIDE SITE DRAINAGE PLAN. | | | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | 4. NEW SLAB ON GRADE SHALL BE DOWLED INTO EXISTING | | | FOUNDATION. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. EXISTING HALL BATH WILL REQUIRE MECHANICAL | | | VENTILATION PER R303.3 | | | | | | 6. PROVIDE ROUGH OPENINGS FOR NEW WINDOWS AND DOORS. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 7. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2020-04-29 16:36:43 | PLAN REVIEW - ELECTRICAL | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? BUILDING - PX3169 | | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SMOKE DETECTOR CANNOT BE WITHIN THREE FEET OF | | | BATHROOM DOOR PER R314.3 | | | | | | R314.1 GENERAL. | | | SMOKE ALARMS SHALL COMPLY WITH NFPA 72 AND SECTION | | | R314. | | | R314.3 LOCATION. | | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | 1. 1.IN EACH SLEEPING ROOM. | | | 2. 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE | | | IMMEDIATE VICINITY OF THE BEDROOMS. | | | 3. 3.ON EACH ADDITIONAL STORY OF THE DWELLING, | | | INCLUDING BASEMENTS AND HABITABLE ATTICS AND NOT | | | INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN | | | DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND | | | WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT | | | LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL | | | SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED | | | THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW | | | THE UPPER LEVEL. | | | 4. 4.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 | | | FEET (914 MM) HORIZONTALLY FROM THE DOOR OR OPENING OF | | | A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS | | | THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED | | | BY SECTION R314.3 | | | | | | | | | 2. EXISTING WINDOW AT HALL BATH WILL BE REMOVED AND | | | OPENING CLOSED. PROVIDE MECHANICAL VENTILATION PER | | | R303.3 | | | | | | R303.3BATHROOMS. | | | BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR | | | ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN | | | WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.3 M2), | | | ONE-HALF OF WHICH MUST BE OPENABLE. | | | EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE | | | ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE | | | PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE | | | DETERMINED IN ACCORDANCE WITH SECTION M1507. EXHAUST | | | AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE | | | OUTDOORS. | | | | | | | | | 3. INCLUDE EXHAUST FAN ON ELECTRICAL PLAN. INDICATE | | | CIRCUT PROVIDING POWER ON SCHEDULE. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-06-12 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-15 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2020-04-29 16:18:38 | IMPACT FEES | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-22 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-22 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2020-04-22 10:09:45 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT- 20040677 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SHOW HOW THIS NEW EDITION WILL BE | | | MECHANICALLY CONDITIONED. FBC EC R403.7. | | | | | | 2) PLEASE SHOW HOW THE MECHANICAL SYSTEM FOR THIS | | | ADDITION MEETS FBC EC 2017 FBC ENERGY, CHAPTER 5 (RE), | | | EXISTING BUILDINGS, SECTION R502 ADDITIONS, ?ADDITIONS | | | TO AN EXISTING BUILDING, BUILDING SYSTEM OR PORTION | | | THEREOF SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS | | | THOSE PROVISIONS RELATE TO NEW CONSTRUCTION??. | | | SECTION R502.1.1.2 HEATING AND COOLING SYSTEMS. NEW | | | HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE | | | ADDITION SHALL COMPLY WITH SECTIONS RE403.1, RE403.2, | | | RE403.3, R403.5 AND R403.6. | | | | | | 3) PLEASE PROVIDE THE ENERGY GAUGE AND MANUAL J | | | CALCULATIONS FOR THE NEW ADDITION MECHANICAL SYSTEM. | | | FBC EC 101.5.1.1.2 | | | | | | 4) PLEASE PROVIDE DETAILS OF THE CU ANCHORAGE. FBC RES | | | M1307.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2020-04-29 16:20:38 | PLAN REVIEW - ROOFING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? BUILDING - PX3169 | | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | | COMPONENTS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-04-29 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2020-04-29 16:17:20 | PLAN REVIEW - DIGITAL SIGNATURE AND SEAL | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER ? BUILDING - PX3169 | | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | DIGITAL SIGNATURES AND SEALS | | | | | | DESIGN PROFESSIONALS | | | | | | DIGITAL SIGNATURE IS NOT ISSUED IN A MANNER WHICH IS | | | ACCEPTABLE TO EITHER FBPA OR FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS. THIS TYPE OF SELF-CERTIFICATION | | | IS NOT INTENDED TO BE USED FOR PROFESSIONAL PURPOSES. | | | THIRD PARTY CERTIFICATION IS REQUIRED. | | | | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-06-12 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-06-12 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-06-12 08:22:45 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 6/12/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR | | | IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT | | | TO THE ZLDR, SECTION 94-72(A)(2): SINGLE-FAMILY LOW | | | DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM SETBACKS | | | FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | FRONT: 25 FEET | | | CORNER: 12.5 FEET | | | REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS | | | LESS | | | SIDE: 5 FEET MINIMUM, 15 FEET TOTAL | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1443 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG |
|
|
|