| Plan Review Stops For Permit 20040614 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2020-04-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-04-20 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-04-20 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2020-04-20 08:33:00 | NEW HIGH RISE- NO ASBESTOS. JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-16 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-16 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-07 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-07 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-06-21 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-06-21 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-04-20 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-04-20 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2020-04-20 09:28:27 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20040614 | | | ADD: 255 EVERNIA ST. SUITE: 804 | | | CONT: MAJESTIC DESIGN & CONSTRUCTION CORP. | | | TEL: 561-777-3875 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MONDAY APRIL 20/2020 | | | ACTION: DENIED | | | | | | 1) THERE IS A PROPOSED DEMO PLAN, AN EXISTING FLOOR | | | PLAN AND A PROPOSED MEP FLOOR PLAN. THERE IS NO | | | PROPOSED FLOOR PLAN FOR BUILDING SHOWING THE LOCATION | | | OF BATHROOM LAVS, WATERCLOSET?S. ALSO MISSING IS THE | | | NEW KITCHEN CABINET CONFIGURATION, IT IS UNKNOWN IF | | | THERE IS AN ISLAND CABINET AND THE DIMENSIONS BETWEEN | | | ISLAND AND SURROUNDING CABINETS AND APPLIANCES. PLEASE | | | NOTE THIS BUILDING WAS CONFIGURED AFTER THE FAIR | | | HOUSING REQUIREMENTS TOOK PLACE. ADDITIONAL INFORMATION | | | IS REQUIRED TO BE ABLE TO DETERMINE CODE COMPLIANCE. | | | 107.3.5.1. MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1.1 COMMERCIAL BUILDINGS/ BUILDING REVIEW | | | BUILDING FLOOR PLAN | | | FAIR HOUSING REQUIREMENTS. | | | | | | 2) FAIR HOUSING GUIDELINES. 2014 FLORIDA ACCESSIBILITY | | | CODE/ FAIR HOUSING ACCESSIBILITY GUIDELINES. SECTION 3. | | | FAIR HOUSING ACT DESIGN AND CONSTRUCTION REQUIREMENTS. | | | FOR PURPOSES OF THIS SECTION, A COVERED MULTIFAMILY | | | DWELLING SHALL BE DEEMED TO BE DESIGNED AND CONSTRUCTED | | | FOR FIRST OCCUPANCY ON OR BEFORE MARCH 13, 1991, IF | | | THEY ARE OCCUPIED BY THAT DATE OR IF THE LAST BUILDING | | | PERMIT OR RENEWAL THEREOF FOR THE COVERED MULTIFAMILY | | | DWELLINGS IS ISSUED BY A STATE, COUNTY OR LOCAL | | | GOVERNMENT ON OR BEFORE JANUARY 13, 1990. | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | | | | JAMES A. WITMER BN, PX, SFP & CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-01 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-01 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-30 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-30 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2020-04-30 13:21:11 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW THAT IS DESIGNED | | | BY AND SIGNED AND SEALED BY A LICENSED DESIGN | | | PROFESSIONAL OR DESIGNED BY AND SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | 2. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC EX 607.1.1 | | | OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC 210.8(D) | | | 4. CONFIRM IF ANY LOAD IS BEING ADDED. IF LOAD IS BEING | | | ADDED, PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30 | | | 5. PROVIDE RISER DIAGRAM OF EXISTING SERVICE TO CONFIRM | | | CAPACITY. NEC 215.5; WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-14 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2020-07-14 11:36:53 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED | | | CONTRACTORS FOR CODE COVERAGE COMPLIANCE. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS | | | AND SHOP DRAWINGS. | | | | | | 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR | | | FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-06-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-17 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2020-06-17 12:53:20 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED | | | CONTRACTORS FOR CODE COVERAGE COMPLIANCE. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS | | | AND SHOP DRAWINGS. | | | | | | 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR | | | FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-04-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-04-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-04-16 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2020-04-16 12:26:03 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED | | | CONTRACTORS FOR CODE COVERAGE COMPLIANCE. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS | | | AND SHOP DRAWINGS. | | | | | | 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR | | | FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-16 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-13 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-07-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-06 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-01 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-16 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-04-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-15 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-15 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-15 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-08 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-08 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2020-07-08 15:02:40 | 3RD REVIEW FBC-2017 PLUMBING | | | PERMIT #20040614 | | | 7/8/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P1: PLEASE PROVIDE THE SCOPE OF WORK FOR THE WATER | | | HEATER- LABEL IT AS EITHER NEW, EXISTING, RELOCATED- | | | SECTION 107.2.1 WPB. AN EQUIPMENT SCHEDULE IS REQUIRED | | | FOR NEW WATER HEATERS. THE SCHEDULE SHALL INDICATE MAKE | | | AND MODEL NUMBER, GALLON SIZE, AND EFFICIENCY RATING- | | | SEE TABLE C404.2 FBC EC. THE DETAIL SHOWS THE PAN DRAIN | | | LINE TO DISCHARGE INTO THE NEAREST SANITARY DRAIN WHICH | | | IS NOT AN APPROVED LOCATION. THIS MAY BE A TYPO AND | | | THERE IS ACCESS TO THE BUILDING STORM DRAIN RISER IN | | | THE CLOSET- SECTION 504.7.2 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-06-22 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-06-22 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2020-06-22 15:38:12 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT #20040614 | | | 6/22//2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS A0, A1, & P1: THE REVISED PLANS SHOW BATHTUB | | | TO SHOWER CONVERSIONS IN THE BATHROOMS. COMPLIANCE WITH | | | THE FAIR HOUSING ACCESSIBILITY GUIDELINES IS REQUIRED. | | | BECAUSE THE BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH | | | THE ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT | | | AND THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN | | | DWELLING UNITS, THE ALTERATIONS THAT ARE PROPOSED IN | | | THE BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR | | | HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES | | | ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017 | | | SIXTH EDITION. COMPLIANCE WITH THE GUIDELINES REQUIRES | | | THAT CLEAR FLOOR SPACES FOR WHEELCHAIR APPROACHES TO | | | BATH FIXTURES SHALL EITHER BE MAINTAINED AS ORIGINALLY | | | DESIGNED OR PROVIDED WHERE NEW FIXTURES ARE BEING | | | INSTALLED. BASED ON THE DRAWINGS IT IS NOT CLEAR IF | | | USUABLE BATHROOM TYPE A OR B WAS CHOSEN AS THE ORIGINAL | | | DESIGN. THE DESIGNER OF RECORD MUST INDICATE WHCH TYPE | | | DESIGN WAS USED ON THE PLAN, AND THEN PROVIDE ENLARGED | | | DIMENSIONED DRAWINGS OF THE BATHROOMS WITH CLEAR FLOOR | | | SPACE DIAGRAMS CONFIGURED FOR THE SHOWERS. PLEASE SEE | | | REQUIREMENT 7 CONTAINED IN THE GUIDELINES AND FIGURE 5, | | | AND FIGURES 7A, 7C, & 7D FOR GUIDANCE. REINFORCEMENTS | | | FOR FUTURE GRAB BAR AND WALL HUNG BENCH SEAT | | | INSTALLATIONS ARE ALSO REQUIRED. PROVIDE DIMENSIONED | | | ELEVATION VIEWS AND DETAILS SHOWING THE LOCATIONS OF | | | THE WALL REINFORCEMENTS. | | | | | | 1A) AS AN ALTERNATIVE TO MEETING THE GUIDELINES FOR THE | | | BATH ALTERATIONS, THE OWNER AND DESIGNER OF RECORD FOR | | | THE PROPOSED PROJECT MAY PROVIDE A SIGNED AND NOTARIZED | | | AFFIDAVIT WHICH WOULD INDICATE ACKNOWLEDGEMENT THAT THE | | | PROPOSED DESIGN DOES NOT MEET THE REQUIREMENTS OF THE | | | FAIR HOUSING ACCESSIBILITY GUIDELINES, BUT WILL ALSO | | | REQUIRE THE OWNER TO AGREE TO REVERT THE UNIT BACK TO | | | COMPLIANCE AT TIME OF SALE IF SO REQUESTED BY THE | | | BUYER. IF THIS OPTION IS CHOSEN, PLEASE SEND AN EMAIL | | | TO [email protected] AND I WILL SEND A COPY OF THE FAIR | | | HOUSING AFFIDAVIT. IF CHOOSING THIS OPTION IT WOULD BE | | | ADVISABLE AT A MINIMUM TO INSTALL THE SHOWER WALL | | | REINFORCEMENTS. | | | | | | 2) SHEET P1: CONCERNING THE SHOWER DRAIN OUTLETS, SHOW | | | COMPLIANCE WITH ITEMS A, B, & C LISTED BELOW. | | | | | | A) REFER TO SECTION 1002.1 FBC P: THE HORIZONTAL | | | DISTANCE FROM THE CENTERLINE OF THE NEW SHOWER DRAIN | | | OUTLET TO THE CENTERLINE OF THE INLET OF THE EXISTING | | | TRAPS SHALL NOT EXCEED 30". PLEASE PLACE A NOTE ON THE | | | PLAN INDICATING COMPLIANCE. | | | B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE | | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | | SECTION 1-07.2.1 WPB. | | | C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION | | | 714.4.1.2 FBC B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-04-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-04-30 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-30 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2020-04-30 14:39:35 | | | | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT #20040614 | | | 4/30/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SANITARY ISOMETRIC DRAWING FOR THE | | | RELOCATED KITCHEN SINK AND DISHWASHING MACHINE- SECTION | | | 107.3.5.1.3 WPB AMENDMENTS TO THE FBC-17. | | | | | | 2) PROVIDE A WATER RISER DRAWING FOR THE RELOCATED SINK | | | AND DISHWASHING MACHINE- SECTION 107.3.5.1.3 WPB | | | AMENDMENTS TO THE FBC-17. PLEASE NOTE THAT A WATER | | | HAMMER ARRESTOR IS REQUIRED FOR THE WATER SUPPLY LINE | | | TO THE DISHWASHER- SECTION 604.9 FBC P; AND THE SUPPLY | | | LINE SHALL BE PROTECTED AGAINST BACKFLOW BY EITHER AN | | | AIR GAP OR A BACKFLOW PREVENTER- SECTION 409.2 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-16 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-16 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-15 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-15 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2020-07-15 11:53:44 | THE PLANS ARE NOT ELECTRONICALLY SIGNED AND SEALED BY | | | THE ARCHITECT OF RECORD- FL STATUTE 481.221 AND SECTION | | | 61G1-16.005 FLORIDA ADMINISTRATIVE CODE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-08 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-08 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2020-07-08 15:05:48 | THE PLANS ARE NOT ELECTRONICALLY SIGNED AND SEALED BY | | | THE ARCHITECT OF RECORD- FL STATUTE 481.221 AND SECTION | | | 61G1-16.005 FLORIDA ADMINISTRATIVE CODE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-01 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-01 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2020-07-01 10:23:06 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGES DOWNLOADED ON 6/16 ARE NOT DIGITALLY SIGNED. | | | | | | PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF RECORD | | | | | | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | | 471.003(2)(H); 471.025; FBC 107.2. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-30 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-30 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2020-04-30 13:24:09 | ELECTRICAL PLAN MUST BE DESIGNED BY AND SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR DESIGNED BY | | | AND SIGNED BY THE ELECTRICAL CONTRACTOR QUALIFIER. THE | | | GENERAL CONTRACTOR IS NOT PERMITTED TO DESIGN | | | ELECTRICAL DOCUMENTS. DIGITAL PLAN REQUIRES A DIGTAL | | | SIGNATURE. PROVIDE CORRECTION. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5, 105.1 |
|
|