Plan Review Details - Permit 20040603
| Plan Review Stops For Permit 20040603 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-24 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-24 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-22 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-22 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-04-22 15:01:10 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT SIGNED AND SEALED ENGINEERING FOR DETERMINING | | | THE OPENING PRESSURES. SPECIFY THE WINDSPEED, EXPOSURE | | | CATEGORY AND MEAN ROOF HEIGHT OF THE BUILDING. FBC | | | 107.2.1 THIS IS A FIVE STORY CONDOMINUM BUILDING, THE | | | 2017 FBC RESIDENTIAL DOES NOT APPLY. THE RESIDENTIAL | | | CODE ONLY APPLIES TWO ONE AND TWO FAMILY DWELLINGS AND | | | TOWNHOUSES NO MORE THAN THREE STORIES. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-24 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-23 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-22 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-20 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-24 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-24 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-22 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-22 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2020-04-22 15:01:40 | SEE BUILDING COMMENTS. |
|
|
|