Plan Review Details - Permit 20040528
Plan Review Stops For Permit 20040528
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-08-04 Cont ID  
Sent By rmcdouga Date 2020-08-04 Time 11:13 Rev Time 0.00
Received By rmcdouga Date 2020-08-04 Time 10:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-08 Cont ID  
Sent By rmcdouga Date 2020-07-08 Time 08:29 Rev Time 0.00
Received By rmcdouga Date 2020-07-08 Time 08:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By rmcdouga Date 2020-04-21 Time 14:54 Rev Time 0.00
Received By rmcdouga Date 2020-04-21 Time 14:54 Sent To  
Notes
2020-04-21 15:08:38PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO COMPLETE SETS OF PLANS FOR THE PROPOSED
 DECK. SPECIFY THE DESIGN WIND SPEED AND EXPOSURE
 CATEGORY ON THE PLANS. DRAWINGS SHALL BE DIMENSIONED,
 CLEARLY DRAWN TO DRAFTSMAN QUALITY AND NOT LESS THAN
 1/8" SCALE. THE DRAWINGS SHALL SPECIFY THE DIMENSION
 AND SPACIFING OF ALL FRAMING MEMBERS, DECKING MATERIAL,
 STEPS, STAIRS RALINGS ETC. ALL CONNECTORS, ANCHORS,
 NAILS, SCREWS ETC. SHALL BE LISTED. FBC 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION
 DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED
 WHEN APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN.
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-08-04 Cont ID  
Sent By fmittner Date 2020-08-04 Time 09:12 Rev Time 0.00
Received By fmittner Date 2020-08-04 Time 09:12 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By fmittner Date 2020-04-15 Time 15:54 Rev Time 0.00
Received By fmittner Date 2020-04-15 Time 15:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-08-04 Cont ID  
Sent By rmcdouga Date 2020-08-04 Time 11:14 Rev Time 0.00
Received By rmcdouga Date 2020-07-23 Time 07:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-17 Cont ID  
Sent By cpuell Date 2020-07-17 Time 12:48 Rev Time 0.00
Received By cpuell Date 2020-06-29 Time 07:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-21 Cont ID  
Sent By rmcdouga Date 2020-04-21 Time 15:09 Rev Time 0.00
Received By rmcdouga Date 2020-04-14 Time 11:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-08-04 Cont ID  
Sent By rmcdouga Date 2020-08-04 Time 11:14 Rev Time 0.00
Received By rmcdouga Date 2020-08-04 Time 10:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-08 Cont ID  
Sent By rmcdouga Date 2020-07-08 Time 08:29 Rev Time 0.00
Received By rmcdouga Date 2020-07-08 Time 08:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By rmcdouga Date 2020-04-21 Time 14:54 Rev Time 0.00
Received By rmcdouga Date 2020-04-21 Time 14:54 Sent To  
Notes
2020-04-21 15:09:13FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2020-08-04 Cont ID  
Sent By fmittner Date 2020-08-04 Time 09:12 Rev Time 0.00
Received By fmittner Date 2020-08-04 Time 09:12 Sent To  
Notes
2020-08-04 09:13:44APPROVED SINCE COLUMNS NOW 5' MINIMUM OFF PROPERTY
 LINES

Review Stop Z ZONING
Rev No 2 Status F Date 2020-07-17 Cont ID  
Sent By fmittner Date 2020-07-17 Time 12:32 Rev Time 0.00
Received By fmittner Date 2020-07-17 Time 12:32 Sent To  
Notes
2020-07-17 12:32:45APPLICATION HAS CHANGED FROM DECK TO PERGOLA. COLUMNS
 SHALL BE A MINIMUM OF 5' OFF PROPERTY LINES.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By fmittner Date 2020-04-15 Time 15:54 Rev Time 0.00
Received By fmittner Date 2020-04-15 Time 15:54 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy