Plan Review Details - Permit 20040504
| Plan Review Stops For Permit 20040504 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-06-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-16 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-04-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-04-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2020-04-22 10:28:35 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE IS A SHEET CONTAINED IN THE BACKUP INFORMATION | | | FROM TLC; SUB # 263213, NAME: FUEL TANK SUBSTITUTION | | | REQUEST, THAT INDICATES "ODES NOT CONFORM TO DESIGN | | | CONCEPT....." | | | | | | THERE ARE THREE (3) POINTS SUBMITTED TO ADDRESS. | | | | | | PLEASE PROVIDE A DETAILED RESPONSE TO THE THREE (3) | | | POINTS ADDRESSED TO TLC'S AND TLC'S CHANGING THE STATUS | | | TO "CONFORMS TO DESIGN CONCEPT" | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-28 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-28 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2020-08-28 16:04:21 | COMMENTS FROM DERM: | | | | | | 1) THE TANK SCHEMATIC "ENGINE OR DAY TANK SUPPLY" | | | (ATTACHMENT 1086 GEN. FUEL TANK (R4)_TLC ?); THE SUPPLY | | | LINE REQUIRES AN ANTISIPHON DEVICE IF THE END DIPS | | | BELOW THE TOP OF TANK. THE ORDER OF COMPONENTS COMING | | | FROM TOP OF TANK ARE 1ST THE BLOCK VALVE THEN | | | ANTISIPHON DEVICE. | | | 2) THE RETURN LINE; IF IT IS CAPABLE OF SIPHONING THE | | | TANK; IT COULD HAVE A BLEEDER HOLE AS THE PLANS STATE | | | THE TANK FILL LINE WILL HAVE. (I DON'T REGULARLY SEE | | | RETURN LINES THAT RUN TO BOTTOM OF SUPPLY TANK WITH | | | DIFFUSERS). | | | 3) I COULD NOT TELL, BUT TANKS MAIN PRIMARY VENT MUST | | | BE VENTED OUTSIDE | | | 4) OFTEN MISSED: TANK ROOMS REQUIRE A 4? CURB AT DOOR | | | OPENINGS (PREVENTS A FUEL RELEASE FLOWING DOWN | | | HALLWAYS) | | | | | | TANK SECONDARY MUST BE TESTED AFTER INSTALLATION; | | | ALONG WITH OVERFILL PROTECTION DEVICE AND LEAK | | | DETECTION DEVICES. | | | WERE GIVEN 30 DAY NOTICE OF INSTALLATIONS, THE 48-72 | | | HRS PRIOR TO WORK SO WE CAN SCHEDULE AN INSPECTION. | | | | | | PBCDERM TANK INSPECTOR: JONATHAN ARLINE | | | SENIOR ENVIRONMENTAL ANALYST | | | PALM BEACH COUNTY DEPT. ENVIRONMENTAL RESOURCES | | | MANAGEMENT / STORAGE TANK REGULATION | | | 2300 NORTH JOG RD., 4TH FLOOR, WEST PALM BCH., FL | | | 33411-2743 | | | TEL. (561)-233-2535. FAX: (561) 233 2414 / E-MAIL: | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-06-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-06-16 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-15 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-04-22 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-21 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-22 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-22 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-06-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-16 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-22 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-22 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
|