Plan Review Details - Permit 20040233
Plan Review Stops For Permit 20040233
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-05-26 Cont ID  
Sent By rmcphers Date 2020-05-26 Time 15:39 Rev Time 0.00
Received By rmcphers Date 2020-05-26 Time 15:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-23 Cont ID  
Sent By rmcphers Date 2020-04-23 Time 10:41 Rev Time 0.00
Received By rmcphers Date 2020-04-22 Time 15:56 Sent To  
Notes
2020-04-23 10:39:01SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ROOF SLOPE TO COMPLY WITH FBC R905.9.1
 2) SURVEY PROVIDED NEEDS TO BE ELECTRONICALLY SIGNED BY
 THE SURVEYOR TO BE USED IN ELECTRONIC PLAN REVIEW.
 3) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT
 (GEOTECHNICAL REPORT) FROM AN ARCHITECT OR ENGINEER FOR
 THE SOIL BEARING CAPACITY. FBC R401.4
 4) IN THE ROOFING PRODUCT APPROVALS - PLEASE CIRCLE THE
 PRODUCTS TO BE USED, THE ROOFING SYSTEMS TO BE USED
 ETC.. PLEASE PROVIDE SIGNED AND SEALED ADDITIONAL
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOFING ZONES 2 AND 3 WHICH MAY REQUIRE HIGHER
 PRESSURES THAN THE PRODUCT APPROVAL ROOFING SYSTEM
 USED. (SEE PRODUCT APPROVALS).
 5) PLEASE PROVIDE THE FRONT PAGES FOR THE OVERHEAD DOOR
 PRODUCT APPROVAL.
 6) PLEASE SHOW ALL ROOF SLOPES.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-06-10 Cont ID  
Sent By jpearson Date 2020-06-10 Time 15:30 Rev Time 0.00
Received By jpearson Date 2020-06-10 Time 15:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-06-03 Cont ID  
Sent By jpearson Date 2020-06-03 Time 12:57 Rev Time 0.00
Received By jpearson Date 2020-06-03 Time 09:56 Sent To  
Notes
2020-06-03 12:57:18CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. PLAN STATES THERE IS NO CHANGE TO THE RISER DIAGRAM,
 BUT THE LOAD TABLE STATES THE UPGRADED ELECTRICAL
 SERVICE IS 200 AMPS. WHICH IS IT? PROVIDE
 CLARIFICATION. PROVIDE RISER DIAGRAM OF EXISTING
 SERVICE. NEC 215.5; WPB FBC 107.2.1 (THERE ARE
 DISCREPANCIES WITH THE RISER DIAGRAM. IS THIS A 200 AMP
 AS INDICATED IN THE MAIN PANEL SCHEDULE? OR IS THIS A
 400 AMP PANEL AS INDICATED IN THE RISER DIAGRAM? OR IS
 THIS A 325 AMP SERVICE AS INDICATED IN THE RISER
 DIAGRAM? INFORMATION ON PLAN NEEDS TO BE CONSISTENT.
 WIRE SIZE IS DETERMINED BY THE OVER CURRENT PROTECTION
 OF THE MAIN PANEL. PROVIDE CORRECTION AND
 CLARIFICATIONS.)
 2. CORRECTED.
 3. CORRECTED.
 4. CORRECTED.
 5. IF NEW SERVICE IS TO BE INSTALLED, PROVIDE AVAILABLE
 SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING
 INFORMATION FROM THE POWER COMPANY STATING WHAT THE
 AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO
 CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT
 IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 (NOT
 PROVIDED.)
 6. CORRECTED.
 7. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-04-23 Cont ID  
Sent By jpearson Date 2020-04-23 Time 15:12 Rev Time 0.00
Received By jpearson Date 2020-04-23 Time 11:11 Sent To  
Notes
2020-04-23 15:12:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN STATES THERE IS NO CHANGE TO THE RISER DIAGRAM,
 BUT THE LOAD TABLE STATES THE UPGRADED ELECTRICAL
 SERVICE IS 200 AMPS. WHICH IS IT? PROVIDE
 CLARIFICATION. PROVIDE RISER DIAGRAM OF EXISTING
 SERVICE. NEC 215.5; WPB FBC 107.2.1
 2. AFCI PROTECTION SHOWN IN NOTE 8 IS NOT CODE
 COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902;
 FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE.
 3. NOTE 19 STATES THAT LIGHTING IN CLOTHES CLOSETS
 SHALL COMPLY WITH NEC 4/10.8/D/1, WHICH DOESN?T EXIST.
 PROVIDE CORRECTION OR NOTE OR COMPLIANCE. NEC 410.16;
 FBC RE E4003.12
 4. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 5. IF NEW SERVICE IS TO BE INSTALLED, PROVIDE AVAILABLE
 SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING
 INFORMATION FROM THE POWER COMPANY STATING WHAT THE
 AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO
 CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT
 IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3
 6. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN
 KITCHEN, INCLUDING THE ISLAND, REQUIRE GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6
 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-05-20 Cont ID  
Sent By fmittner Date 2020-05-20 Time 16:26 Rev Time 0.00
Received By fmittner Date 2020-05-20 Time 16:26 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By fmittner Date 2020-04-15 Time 10:55 Rev Time 0.00
Received By fmittner Date 2020-04-15 Time 10:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-06-11 Cont ID  
Sent By lmarchan Date 2020-06-11 Time 08:29 Rev Time 0.00
Received By lmarchan Date 2020-06-10 Time 14:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-06-03 Time   Rev Time 0.00
Received By lmarchan Date 2020-05-13 Time 10:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-04-23 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-10 Time 14:13 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-06-15 Cont ID  
Sent By lmarchan Date 2020-06-15 Time 15:44 Rev Time 0.00
Received By lmarchan Date 2020-06-11 Time 13:08 Sent To  
Notes
2020-06-15 15:45:03NO FEES DUE PER IMPACT OFFICE. LEM
2020-06-11 13:08:316/11/20 SENT TO IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-04-23 Cont ID  
Sent By rmcphers Date 2020-04-23 Time 10:39 Rev Time 0.00
Received By rmcphers Date 2020-04-23 Time 10:39 Sent To  
Notes
2020-04-23 10:40:10PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-06-10 Cont ID  
Sent By medwards Date 2020-06-10 Time 17:04 Rev Time 0.00
Received By medwards Date 2020-06-10 Time 17:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-05-21 Cont ID  
Sent By medwards Date 2020-05-21 Time 13:15 Rev Time 0.00
Received By medwards Date 2020-05-21 Time 11:56 Sent To  
Notes
2020-05-21 13:16:081ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20040233
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE ANCHORAGE OF APPLIANCES DETAIL. BFC
 RES M1307.2
  
 2) PLEASE SHOW KITCHEN VENTILATION. FBC M TABLE
 403.3.1.1
  
 3) PLEASE PROVIDE INFORMATION FOR THE COOKING
 EQUIPMENT. IS A HOOD BEING USED? IF SO, PLEASE PROVIDE
 INFORMATION ON THE HOOD, INCLUDING THE CFM?S. FBC FS
 107.2.1
  
 4) PLEASE SHOW THE BATHROOM EXHAUSTS. FBC M TABLE
 403.3.1.1
  
 5) IS AHU IN ATTIC? IF SO PLEASE PROVIDE A DETAIL
 DRAWING SHOWING THE UNIT WITH THE OVERFLOW PAN WITH THE
 FLOAT SWITCH. ALSO IDENTIFY CONDENSATE PIPING ALONG
 WITH PIPE SIZE AND LOCATION OF THE TERMINATION ON THE
 DRAWING. FBC FS 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-04-15 Cont ID  
Sent By medwards Date 2020-04-15 Time 16:30 Rev Time 0.00
Received By medwards Date 2020-04-15 Time 16:21 Sent To  
Notes
2020-04-15 16:31:12NO MECHANICAL WORK SHOWN UNDER THIS PROJECT.

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By lcrespo Date 2020-04-15 Time 07:31 Rev Time 0.00
Received By lcrespo Date 2020-04-15 Time 07:04 Sent To  
Notes
2020-04-15 07:31:2704/15/20 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL,
 CONTRACTORS OR THEIR REPRESENTATIVES FROM THE
 RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM TO 7:30 / 2:00 PM TO 5:00 PM
 EMAIL: [email protected] CELL: 561-701-6437
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-05-26 Cont ID  
Sent By rmcphers Date 2020-05-26 Time 15:40 Rev Time 0.00
Received By rmcphers Date 2020-05-26 Time 15:40 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-04-23 Cont ID  
Sent By rmcphers Date 2020-04-23 Time 10:40 Rev Time 0.00
Received By rmcphers Date 2020-04-23 Time 10:40 Sent To  
Notes
2020-04-23 10:40:39SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-06-10 Cont ID  
Sent By jpearson Date 2020-06-10 Time 15:04 Rev Time 0.00
Received By jpearson Date 2020-06-10 Time 15:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-05-21 Cont ID  
Sent By medwards Date 2020-05-21 Time 13:22 Rev Time 0.00
Received By medwards Date 2020-05-21 Time 13:16 Sent To  
Notes
2020-05-21 13:24:23SHEET M-1: THE DESIGNER WILL NEED TO SIGN AND DATE THE
 DRAWING.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By medwards Date 2020-04-15 Time 16:37 Rev Time 0.00
Received By medwards Date 2020-04-15 Time 16:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-05-20 Cont ID  
Sent By fmittner Date 2020-05-20 Time 16:26 Rev Time 0.00
Received By fmittner Date 2020-05-20 Time 16:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By fmittner Date 2020-04-15 Time 10:55 Rev Time 0.00
Received By fmittner Date 2020-04-15 Time 10:55 Sent To  
Notes
***NONE***