Plan Review Details - Permit 20040103
| Plan Review Stops For Permit 20040103 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-05-14 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-05-14 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-02 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-02 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2020-04-02 14:30:42 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B R TABLES R802.5.1, THE SPANS FOR 2"X 4" RAFTERS | | | EXCEED THE REQUIRED MAXIMUM SPAN. PLEASE CONSIDER USING | | | 2"X 6" IN LIEU OF 2"X 4" RAFTERS THROUGHOUT OR USING AN | | | ALTERNATE METHOD TO REDUCE THE OVERALL SPAN OF THE 2"X | | | 4" RAFTERS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
| Sent By |
rsklarew |
Date |
2020-05-27 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
rsklarew |
Date |
2020-05-14 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-04-11 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-04-11 |
Time |
10:08 |
Rev Time |
|
| Received By |
ccarvaja |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-05-14 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-05-14 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-02 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-02 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2020-04-02 14:35:58 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | ROOFING REVIEW DENIED: | | | | | | FBC B 107, PLEASE PROVIDE THE PRODUCT APPROVALS FOR THE | | | ROOFING MATERIAL TO BE USED. | | | | | | NOTE: A ROOFING SUB-PERMIT HAS BEEN APPLIED FOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-05-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-05-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-04-07 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-04-07 |
Time |
09:01 |
Sent To |
I |
|
| Notes |
| 2020-04-07 09:00:17 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 04/07/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAIL | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. APPLICANT NEEDS TO PROVIDE A SURVEY OF THE | | | PROPERTY. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1443 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | |
|
|
|