| Plan Review Stops For Permit 20040046 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-21 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-21 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-15 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-07 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-07 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2020-05-07 10:51:58 | PAVING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY | | | WITH FBC ACCESSIBILITY 502.2 | | | 2) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND | | | STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | | 3) PARKING ACCESS AISLE CANNOT BE RAISED OR BE PART OF | | | THE ACCESSIBLE RAMP - | | | FBC ACCESSIBILITY 502.4FLOOR OR GROUND SURFACES. | | | PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL | | | COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME | | | LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN | | | LEVEL ARE NOT PERMITTED. | | | | | | EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE | | | PERMITTED. | | | | | | ADVISORY 502.4 FLOOR OR GROUND SURFACES. ACCESS AISLES | | | ARE REQUIRED TO BE NEARLY LEVEL IN ALL DIRECTIONS TO | | | PROVIDE A SURFACE FOR WHEELCHAIR TRANSFER TO AND FROM | | | VEHICLES. THE EXCEPTION ALLOWS SUFFICIENT SLOPE FOR | | | DRAINAGE. BUILT-UP CURB RAMPS ARE NOT PERMITTED TO | | | PROJECT INTO ACCESS AISLES AND PARKING SPACES BECAUSE | | | THEY WOULD CREATE SLOPES GREATER THAN 1:48. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2020-05-04 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-05-04 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2020-05-04 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-21 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-04 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-28 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-06-30 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-06-25 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-04-23 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-21 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-21 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-15 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-07 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-07 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2020-05-07 11:10:56 | LETTER LABELED ( 2190568 7-11 WPB CHANGE TO EOR.PDF ) | | | IN PROJECTDOX "SUPPORTING DOC" FOLDER NEEDS TO BE | | | DIGITALLY SIGNED BY THE ENGINEER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-08-21 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-07-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2020-07-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-24 12:46:36 | *****************ZONING REVIEW FAILED**************** | | | | | | PARKING SPACES HAVE BEEN REMOVED FROM THIS REVISION. | | | | | | PLEASE PROVIDE PARKING COUNT/INFORMATION TABLE ON THE | | | NUMBER OF PARKING SPACES EXISTING AND PROPOSED. THERE | | | SHOULD NOT BE A REDUCTION IN PARKING SPACES. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
awotten |
Date |
2020-06-23 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2020-06-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-06-23 16:49:10 | **********ZONING REVIEW FAILED******** | | | | | | PROVIDE THE DIMENSIONS IN PARKING LOT (TYPICAL PARKING | | | STALLS, ETC.) ON SITE PLAN. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | |
|
|