Plan Review Details - Permit 20031405
Plan Review Stops For Permit 20031405
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-06-16 Cont ID  
Sent By shill Date 2020-06-16 Time 12:24 Rev Time 0.00
Received By shill Date 2020-06-16 Time 12:24 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-04-06 Cont ID  
Sent By rmcphers Date 2020-04-06 Time 15:01 Rev Time 0.00
Received By rmcphers Date 2020-04-06 Time 15:00 Sent To  
Notes
2020-04-06 15:01:22ASBESTOS ? PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM
 THE CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-06-16 Cont ID  
Sent By shill Date 2020-06-16 Time 12:25 Rev Time 0.00
Received By shill Date 2020-06-16 Time 12:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-06 Cont ID  
Sent By rmcphers Date 2020-04-06 Time 14:58 Rev Time 0.00
Received By rmcphers Date 2020-04-06 Time 14:49 Sent To  
Notes
2020-04-06 14:58:15BATHROOM REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING
 TEST REPORTS. IT IS RECOMMENDED THAT THIS BE RESOLVED
 VIA EMAIL PRIOR TO RESUBMITTAL. EMAIL THE NAME OF THE
 UNDERLAYMENT PROPOSED TO [email protected]. IF THE
 MANUFACTURER HAS ALREADY PROVIDED THE REQUIRED TEST
 REPORTS DIRECTLY TO US, TEST REPORTS DO NOT NEED TO BE
 SUBMITTED WHEN RESUBMITTING.
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. PROVIDE A COPY OF THE TEST REPORT.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-04-08 Cont ID  
Sent By jleahy Date 2020-04-08 Time 12:35 Rev Time 0.00
Received By jleahy Date 2020-04-08 Time 12:06 Sent To  
Notes
2020-04-07 07:57:47JAKE LEAHY REVIEWING.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-04-06 Cont ID  
Sent By pleduc Date 2020-04-06 Time   Rev Time 0.00
Received By pleduc Date 2020-04-06 Time 11:28 Sent To  
Notes
2020-04-06 11:30:07THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING AREA
 MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE FIRE
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY A
 CERTIFIED FIRE SPRINKLER CONTRACTOR.
  
 2) ANY AND ALL WORK ON THE FIRE SPRINKLER SYSTEMS SHALL
 BE DONE UNDER SEPARATE SHOP DRAWINGS AND BY A CERTIFIED
 FIRE SPRINKLER CONTRACTOR.
  
 3) THE FIRE SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT
 THE CONSTRUCTION PERIOD.
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-10 Cont ID  
Sent By shill Date 2020-04-10 Time 08:05 Rev Time 0.00
Received By shill Date 2020-03-31 Time 10:29 Sent To  
Notes
2020-04-04 10:30:12CONVERTED TO DIGITAL.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-04-06 Cont ID  
Sent By medwards Date 2020-04-06 Time 11:38 Rev Time 0.00
Received By medwards Date 2020-04-06 Time 10:57 Sent To  
Notes
2020-04-06 11:40:03THERE DOES NOT APPEAR TO BE ANY MECHANICAL WORK BEING
 DONE WITH THIS PERMITTED PROJECT.

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-04-06 Cont ID  
Sent By tklarge Date 2020-04-06 Time 05:00 Rev Time 0.00
Received By tklarge Date 2020-04-06 Time 04:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-04 Cont ID  
Sent By jgomez Date 2020-04-04 Time 11:44 Rev Time 0.00
Received By jgomez Date 2020-04-04 Time 11:43 Sent To  
Notes
2020-04-04 11:45:12ARCHITECT?S ORIGINAL SEAL/SIGNATURE IN CITY'S HARD COPY
 SUBMITTAL. JG.
  