Plan Review Details - Permit 20031382
Plan Review Stops For Permit 20031382
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-04-02 Cont ID  
Sent By dbattles Date 2020-04-02 Time 15:47 Rev Time 0.00
Received By cthroop Date 2020-04-02 Time 14:15 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-04-03 Cont ID  
Sent By fmittner Date 2020-04-03 Time 11:27 Rev Time 0.00
Received By fmittner Date 2020-04-03 Time 11:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-03 Cont ID  
Sent By shill Date 2020-04-03 Time 17:26 Rev Time 0.00
Received By shill Date 2020-03-30 Time 15:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-04-06 Cont ID  
Sent By cmontell Date 2020-03-31 Time 09:35 Rev Time 0.00
Received By medwards Date 2020-04-06 Time 15:21 Sent To  
Notes
2020-04-06 15:23:09ALL INFORMATION WAS LOCATED ON THE MASTER PERMIT
 18091185. MECHANICAL REVISIONS APPROVED.
2020-03-31 09:36:281ST REVIEW FBC-2017 MECHANICAL
 PERMIT- 20031282
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY GAUGE AND THE MANUAL S FOR
 THE MECHANICAL SYSTEM USED. SIMULATED PERFORMANCE
 ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
 FBC EC 101.5.1.1.2
  
 2) PROVIDE THE MANUAL S,J AND D CALCULATIONS FOR THIS
 INSTALLATION. FBC E R403.7.1EQUIPMENT SIZING.
 M1401.3EQUIPMENT AND APPLIANCE SIZING.
  
 3) . BALANCED RETURN AIR - M1602.3
 4) ANCHORAGE OF APPLIANCES - PROVIDE ANCHORING DETAILS
 FOR THE OUTDOOR UNIT. M1307.2
 5) M1507.4LOCAL EXHAUST RATES.
 6) PLEASE PROVIDE THE SPEC. SHEETS FOR ALL EQUIPMENT
 USED. LOCAL EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE
 THE CAPACITY TO EXHAUST THE MINIMUM AIR FLOW RATE
 DETERMINED IN ACCORDANCE WITH TABLE M1507.4.
 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE- AND
 TWO-FAMILY DWELLINGS
 AREA TO BE EXHAUSTED
 EXHAUST RATES
 KITCHENS 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS
 BATHROOMS-TOILET ROOMS MECHANICAL EXHAUST CAPACITY OF
 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-03-31 Cont ID  
Sent By medwards Date 2020-03-31 Time 09:41 Rev Time 0.00
Received By medwards Date 2020-03-31 Time 09:41 Sent To  
Notes
2020-03-31 09:42:021ST CYCLE SIGNATURE REVIEW IS APPROVED. THE 2ND CYCLE
 WILL NEED TO BE REVIEWED ONCE SUBMITTED.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-03 Cont ID  
Sent By fmittner Date 2020-04-03 Time 11:27 Rev Time 0.00
Received By fmittner Date 2020-04-03 Time 11:27 Sent To  
Notes
***NONE***