Plan Review Details - Permit 20031328
| Plan Review Stops For Permit 20031328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-22 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-22 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-21 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-21 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2020-04-21 09:55:44 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ON PRODUCT APPROVAL FL 477-R8 FOR THE FLAT ROOF, | | | SPECIFY THE SYSTEM NUMBER AND MAXIMUM DESIGN PRESSURE | | | ON THE APPROPRIATE ROOF CHART FOR A NON-INSULATED TORCH | | | APPLIED ROOF COVERING. THE MAXIMUM DESIGN ROOF PRESSURE | | | FOR THE SYSTEM WILL HAVE TO BE -90 PSF OR MORE. IF NOT | | | ENGINEERED FASTENER SPACING CALCULATIONS WILL BE | | | REQUIRED, IF ALLOWED BY THE PRODUCT APPROVAL. CLEARLY | | | MARK THE ITEMS THAT APPLY TO YOUR PROJECT ON THE | | | PRODUCT APPROVAL. FBC 107.2.1 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-15 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2020-04-15 14:05:44 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107, PLEASE INDICATE ON THE PRODUCT APPROVAL/TEST | | | REPORT WHICH SYSTEM YOU WILL BE USING AND WHAT THE | | | FASTENER SPACING WILL BE FOR THE BASE SHEET. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-22 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-21 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-21 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-15 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-04-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-15 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-15 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-21 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-21 |
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |