Plan Review Details - Permit 20031313
Plan Review Stops For Permit 20031313
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-20 Cont ID  
Sent By rmcdouga Date 2020-04-20 Time 07:45 Rev Time 0.00
Received By rmcdouga Date 2020-04-20 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-10 Cont ID  
Sent By jbrooks Date 2020-04-10 Time 08:51 Rev Time 0.00
Received By rmcdouga Date 2020-04-10 Time 08:57 Sent To  
Notes
2020-04-10 08:54:11SIGN
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWINGS NEED TO BE ELECTRONICALLY SIGNED BY THE
 ENGINEER TO BE USED IN ELECTRONIC PLAN REVIEW.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By jpearson Date 2020-04-29 Time 12:47 Rev Time 0.00
Received By jpearson Date 2020-04-29 Time 12:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-04-03 Cont ID  
Sent By jleahy Date 2020-04-03 Time 13:12 Rev Time 0.00
Received By jpearson Date 2020-04-03 Time 13:12 Sent To  
Notes
2020-04-03 12:29:12CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. IT APPEARS THAT THE ORIGINAL APPROVED PLAN WAS
 SCANNED AND SUBMITTED FOR THIS REVISION, WHICH IS NOT
 ACCEPTABLE. PROVIDE PLAN SHEET WITH REVISION INDICATED.
 WPB FBC 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-04-29 Cont ID  
Sent By lmarchan Date 2020-04-29 Time 13:35 Rev Time 0.00
Received By lmarchan Date 2020-04-13 Time 09:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-10 Cont ID  
Sent By rmcphers Date 2020-04-10 Time 08:54 Rev Time 0.00
Received By rmcphers Date 2020-03-27 Time 10:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-04-20 Cont ID  
Sent By rmcdouga Date 2020-04-20 Time 07:45 Rev Time 0.00
Received By rmcdouga Date 2020-04-20 Time 07:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-04-03 Cont ID  
Sent By jpearson Date 2020-04-03 Time 12:27 Rev Time 0.00
Received By jpearson Date 2020-04-03 Time 12:27 Sent To  
Notes
2020-04-03 12:27:30PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1; FS
 471/481

Review Stop Z ZONING
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By rfalcone Date 2020-04-29 Time 13:48 Rev Time 0.00
Received By rfalcone Date 2020-04-29 Time 13:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-03 Cont ID  
Sent By rfalcone Date 2020-04-03 Time 16:32 Rev Time 0.00
Received By rfalcone Date 2020-04-03 Time 16:32 Sent To  
Notes
***NONE***