Plan Review Details - Permit 20031160
Plan Review Stops For Permit 20031160
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By rmcphers Date 2020-09-02 Time 10:01 Rev Time 0.00
Received By rmcphers Date 2020-09-02 Time 10:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-06-30 Cont ID  
Sent By rmcphers Date 2020-06-30 Time 13:34 Rev Time 0.00
Received By rmcphers Date 2020-06-30 Time 13:13 Sent To  
Notes
2020-06-30 13:18:33NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PRODUCT APPROVALS FOR THE PLASTPRO DOORS DO NOT SHOW
 AN ATTACHMENT ANCHOR TYPE TO METAL FRAME. PLEASE SHOW
 ON THE DRAWINGS THE ANCHORS TO USE FOR THE FASTENING OF
 THE PLASTPRO DOORS.
 2) MASONITE DOOR PROVIDED DOES NOT APPEAR TO HAVE AN
 APPROVED MIAMI DADE OR FLORIDA STATE PRODUCT APPROVAL.
 3) ROOFING PRODUCT APPROVAL = ROOFING SYSTEM MARKED ON
 THE PRODUCT APPROVAL SHOWS A MAX. WIND DESIGN PRESSURE
 OF (-52.5) - PLEASE SEE NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL AND PROVIDE SIGNED AND SEALED ADDITIONAL
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ZONES 2 AND 3 THAT MAY BE HIGHER WIND PRESSURE THAN THE
 MAX. SHOWN ON THE PRODUCT APPROVAL.
 4) PLEASE SHOW HOW THE 1 5/8 INCH METAL STUDS ARE
 FASTENED TO THE METAL BUILDING (TYPE, SIZE AND ON
 CENTER SPACING OF FASTENERS). TO COMPLY WITH THE WIND
 LOADS PER FBC 1609
 5) SHOW HOW THE LATH IS FASTENED TO THE METAL SDUDS
 ETC. TO COMPLY WITH THE WIND LOADS FBC 1609

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By rmcphers Date 2020-04-21 Time 10:37 Rev Time 0.00
Received By rmcphers Date 2020-04-20 Time 14:04 Sent To  
Notes
2020-04-21 10:37:43NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) ATTACHMENT TO FOUNDATION = DRAWING S1 SHOWS 2-#5'S 8
 INCH LONG BOLTS - DRAWING A-2 SHOWS 2-12 INCH LONG
 DOWELS. PLEASE CLARIFY (BOLTS OR DOWELS? DOWELS WHAT
 DIAMETER? 8" OR 12" LONG?).
 2) PLEASE SHOW THE THICKNESS OF THE CONCRETE PATIO
 SLABS.
 3) PLEASE SHOW ALL ATTACHMENTS (TYPE, DIAMETER, LENGTH
 AND ON CENTER SPACING = WALL SHEATHING TO METAL
 FRAMING, LATH TO METAL FRAMING, STRAPPING NAIL
 REQUIREMENTS, HUC 28 HANGER TO METAL CONTAINER, PARAPET
 WALL SILL PLATE BOLT ON CENTER SPACING ETC.
 4) PRODUCT APPROVALS FOR THE DOORS AND WINDOWS DO NOT
 SHOW AN ATTACHMENT ANCHOR TYPE TO METAL.
 5) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT.
 (ELECTRONICALLY SIGNED FOR USE IN ELECTRONIC PLAN
 REVIEW).
 6) INSULATION SHOWN FOR WALLS AND CEILINGS NEEDS TO
 MATCH OR EXCEED WHAT IS SHOWN ON THE ENERGY CALCS. (
 ENERGY CALCS. NOT YET PROVIDED)
 7) PLEASE SHOW ROOF CLADDING PRESSURES FOR WIND ZONES
 1,2 AND 3.
 8) ROOFING PRODUCT APPROVAL = ROOFING SYSTEM MARKED ON
 THE PRODUCT APPROVAL SHOWS A MAX. WIND DESIGN PRESSURE
 OF (-52.5) - PLEASE SEE NOTE NUMBER 7 ON THE PRODUCT
 APPROVAL AND PROVIDE SIGNED AND SEALED ADDITIONAL
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ZONES 2 AND 3 THAT MAY BE HIGHER WIND PRESSURE THAN THE
 MAX. SHOWN ON THE PRODUCT APPROVAL.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By jleahy Date 2020-09-02 Time 08:17 Rev Time 0.00
Received By jleahy Date 2020-09-02 Time 08:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-07-02 Cont ID  
Sent By jleahy Date 2020-07-02 Time 16:28 Rev Time 0.00
Received By jleahy Date 2020-07-02 Time 16:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-04-23 Cont ID  
Sent By jpearson Date 2020-04-23 Time 08:01 Rev Time 0.00
Received By jpearson Date 2020-04-23 Time 07:18 Sent To  
Notes
2020-04-23 07:42:20CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. RISER DIAGRAM IS NOT CODE COMPLIANT. SERVICE
 CONDUCTORS ARE NOT PERMITTED TO EXTEND FURTHER THAN 8
 FEET INTO A STRUCTURE WITHOUT OVERCURRENT PROTECTION.
 IF THIS OVERCURRENT PROTECTION IS LOCATED ON THE
 EXTERIOR OF THE DWELLING, THAN THE CONDUIT TO THE
 INTERIOR PANEL MUST INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. RISER SHOWS WHAT APPEARS TO BE A METER CAN
 ONLY LABELED AS A METER MAIN DISCONNECT OUTSIDE, BUT
 ALSO SHOWS A MAIN BREAKER PANEL INSIDE. IF THE
 CONDUCTORS ARE RUN UNDERGROUND FROM THE METER TO THE
 INTERIOR PANEL, AND THAT PANEL HAS A MAIN BREAKER, THE
 CONDUCTORS MUST NOT EXCEED 8 FEET IN LENGTH BEFORE
 TERMINATION TO THE MAIN BREAKER. PROVIDE CLARIFICATION
 AND/OR CORRECTION. NEC 230.70, 250.122; FBC RE E3601.6,
 E3704.6, 3607.3.1
 2. AFCI PROTECTION SHOWN IN NOTE 21 IS NOT CODE
 COMPLIANT. THIS NOTE ONLY REQUIRES RECEPTACLES TO BE
 AFCI PROTECTED. ALL BRANCH CIRCUITS THAT SUPPLY
 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS
 INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS,
 LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
 SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS,
 LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI
 PROTECTED. THIS INCLUDES LIGHTING AND POWER OUTLETS AND
 RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI AND GFCI
 PROTECTION. PROVIDE CORRECTION. NEC 210.8, 210.12; FBC
 RE E3902
 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 4. FAULT CURRENT CALCULATION IS INCORRECT. THIS IS NOT
 A PARALLEL SERVICE, SO THERE WOULD NOT BE 2 CONDUCTORS
 PER PHASE. ALSO, RISER DIAGRAM DOES NOT SHOW THE WIRE
 FROM THE FPL TRANSFORMER TO THE METER MAIN DISCONNECT,
 SO HOW WAS THIS CALCULATION PERFORMED? WHAT WIRE SIZE
 WAS USED? PROVIDE CORRECTED CALCULATION. NEC 110.9,
 110.10; FBC RE E3606.3
 5. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL
 SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. THE
 WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER SPACE
 STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED SO
 THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THIS INCLUDES ANY WALL SPACE 2 FEET OR
 MORE IN WIDTH. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1); FBC RE E3901
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By fmittner Date 2020-09-02 Time 15:30 Rev Time 0.00
Received By fmittner Date 2020-09-02 Time 15:30 Sent To  
Notes
2020-09-02 15:30:48PASSED WITH PROVISO THAT ALL WINDOWS SHALL HAVE
 EXTERIOR DIMENSIONAL MUNTINS AS CONFIRMED IN E-MAIL BY
 OWNER

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2020-07-06 Cont ID  
Sent By fmittner Date 2020-07-06 Time 15:44 Rev Time 0.00
Received By fmittner Date 2020-07-06 Time 15:44 Sent To  
Notes
2020-07-06 15:44:24NEED EXTERNAL GRIDS ON ALL WINDOWS

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-04-29 Cont ID  
Sent By fmittner Date 2020-04-29 Time 15:38 Rev Time 0.00
Received By fmittner Date 2020-04-29 Time 15:38 Sent To  
Notes
2020-04-29 15:38:56ALL WINDOWS NEED EXTERIOR DIMESNIONAL GRIDS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-29 Cont ID  
Sent By lmarchan Date 2020-09-29 Time 14:56 Rev Time 0.00
Received By lmarchan Date 2020-09-11 Time 09:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-10 Cont ID  
Sent By lmarchan Date 2020-09-10 Time 15:46 Rev Time 0.00
Received By lmarchan Date 2020-08-15 Time 10:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-07 Cont ID  
Sent By lmarchan Date 2020-07-07 Time 14:44 Rev Time 0.00
Received By lmarchan Date 2020-06-19 Time 08:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-05-11 Cont ID  
Sent By lmarchan Date 2020-05-11 Time 07:56 Rev Time 0.00
Received By lmarchan Date 2020-04-10 Time 14:32 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-09-29 Cont ID  
Sent By lmarchan Date 2020-09-29 Time 16:22 Rev Time 0.00
Received By lmarchan Date 2020-09-11 Time 09:48 Sent To  
Notes
2020-09-26 08:24:24RECEIPT MU-2020-35555 - $1693.14 - PAID
2020-09-11 09:48:299/11/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By rmcphers Date 2020-04-21 Time 10:38 Rev Time 0.00
Received By rmcphers Date 2020-04-21 Time 10:38 Sent To  
Notes
2020-04-21 10:48:40PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-07-07 Cont ID  
Sent By medwards Date 2020-07-07 Time 14:32 Rev Time 0.00
Received By medwards Date 2020-07-07 Time 14:32 Sent To  
Notes
2020-07-07 14:33:39THIS PROJECT IS APPROVED WITH A NOTE:
 FIELD INSPECTOR TO VERIFY CONNECTION OF BATH EXHAUST
 DUCT TO THE ROOF JACK AND VERIFY THE EXHAUST OPENING
 MEETS FBC M 501.3.2 FOR OPENING PROTECTION WITH
 SCREENS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-04-13 Cont ID  
Sent By medwards Date 2020-04-13 Time 14:08 Rev Time 0.00
Received By medwards Date 2020-04-13 Time 13:50 Sent To  
Notes
2020-04-13 14:08:551ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20031160
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE CODE COMPLIANT MECHANICAL PLAN. FBC FS
 107.2.1
 2) PROVIDE ENERGY SUBMITTAL. FBC EC 101.5.1.1.2
 3) PROVIDE MANUAL J CALCULATIONS FOR THE MECHANICAL
 SYSTEM. FBC EC R403.7
 4) PROVIDE KITCHEN AND BATH EXHAUST ACCORDING TO FBC
 RES M1507.4
 5) SHOW CONDENSATE DISPOSAL ON CODE COMPLIANT
 MECHANICAL PLANS. FBC RES M1411.3
 6) SHOW ANCHORAGE OF APPLIANCES DETAIL ON CODE
 COMPLIANT MECHANICAL DRAWINGS. FBC RES M1307.2
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By abelisle Date 2020-09-02 Time 07:43 Rev Time 0.00
Received By abelisle Date 2020-09-02 Time 07:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-06-24 Cont ID  
Sent By ccole Date 2020-06-24 Time 11:53 Rev Time 0.00
Received By ccole Date 2020-06-24 Time 10:13 Sent To  
Notes
2020-06-24 11:54:142ND REVIEW FBC-2017 PLUMBING
 PERMIT #20031160
 6/24/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) EFFICIENCY RATING OF THE WATER HEATER IS NOTED AT
 .93 ON SHEET S-1, BUT THE ENERGY COMPLIANCE FORM
 INDICATES .95.
  
 2) S1 & A1: THE WATER HEATER PAN DRAIN LINE MUST
 TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE
 THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND
 SURFACE - SECTION P2801.6.2 FBC P. THE PLAN APPEARS TO
 SHOW THE LINE RUNNING UNDER THE SLAB WHICH WOULD RESULT
 IN A BELOW GRADE TERMINATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-04-14 Cont ID  
Sent By ccole Date 2020-04-14 Time 17:12 Rev Time 0.00
Received By ccole Date 2020-04-14 Time 15:30 Sent To  
Notes
2020-04-14 17:16:101ST REVIEW FBC-2017 PLUMBING
 PERMIT #20031160
 4/14/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET S1: CORRECT PLUMBING NOTE #4- POLYBUTYL IS NOT
 AN APPROVED DOMESTIC WATER SERVICE OR DISTRIBUTION
 PIPING MATERIAL- SECTIONS P2906.4 & 2906.5 FBC RES.
  
 2) S1: CORRECT PLUMBING NOTE #4- CPVC IS NOT AN
 APPROVED SANITARY PIPING MATERIAL- SECTION P3002.1 FBC
 RES.
  
 3) S1: CORRECT NOTE #16- SHOWER VALVES SHALL BE OF THE
 PRESSURE BALANCED, THERMOSTATIC-MIXING, OR COMBINATION
 PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPES WITH A
 HIGH LIMIT STOP IN ACCORDANCE WITH ASSE A112.106/CSA
 B125.16- SECTION 2708.4 FBC RES.
  
 4) S1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE ELECTRIC
 WATER HEATER THAT INCLUDES THE EFFICIENCY RATING OF THE
 UNIT- TABLE C404.2 FBC EC. PLEASE NOTE THAN AN ENERGY
 COMPLIANCE FORM WAS NOT SUBMITTED- SEE SECTION R101.1.5
 FBC RES.
  
 5) S1 & A1: THE WATER HEATER DETAIL ON S1 SHOWS THE
 RELIEF VALVE PIPE DISCHARGING TO A FLOOR DRAIN, AND A
 OVERFLOW LINE FROM THE DRAIN PAN RUNNING TO THE
 EXTERIOR OF THE BUILDING. PLEASE SHOW THE FLOOR DRAIN
 AND DRAIN LINE RUN ON SHEET A1.
  
 6) A1: ROOM DIMENSIONS AND REQUIRED FIXTURE CLEARANCES
 NOT PROVIDED IN THE BATHROOMS-SECTION 107.2.1 WPB &
 SECTION R307.1 FBC RES.
  
 7) S1 PLUMBING RISER: A) SHOW TWO KS TRAPS. B) SHOW THE
 SIZE OF THE WM STANDPIPE AND TRAP, THE WASTE STACK, AND
 THE VENT- TABLE P3201 FBC RES, SECTION 406.2 FBC P, AND
 TABLE 709.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By rmcphers Date 2020-09-02 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2020-09-02 Time 10:02 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2020-06-30 Cont ID  
Sent By rmcphers Date 2020-06-30 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2020-06-30 Time 13:36 Sent To  
Notes
2020-06-30 13:37:16SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-04-21 Cont ID  
Sent By rmcphers Date 2020-04-21 Time 10:38 Rev Time 0.00
Received By rmcphers Date 2020-04-21 Time 10:38 Sent To  
Notes
2020-04-21 10:38:51SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By rmcphers Date 2020-09-02 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2020-09-02 Time 10:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-06-30 Cont ID  
Sent By rmcphers Date 2020-06-30 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2020-06-30 Time 13:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-21 Cont ID  
Sent By rmcphers Date 2020-04-21 Time 10:48 Rev Time 0.00
Received By rmcphers Date 2020-04-21 Time 10:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2020-09-29 Cont ID  
Sent By fmittner Date 2020-09-29 Time 08:16 Rev Time 0.00
Received By fmittner Date 2020-09-29 Time 08:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2020-09-02 Cont ID  
Sent By fmittner Date 2020-09-02 Time 15:30 Rev Time 0.00
Received By fmittner Date 2020-09-02 Time 15:30 Sent To  
Notes
2020-09-02 15:31:26STILL NEEDS SEPARATE LANDSCAPE PERMIT SUBMITTAL

Review Stop Z ZONING
Rev No 2 Status F Date 2020-07-06 Cont ID  
Sent By fmittner Date 2020-07-06 Time 15:43 Rev Time 0.00
Received By fmittner Date 2020-07-06 Time 15:43 Sent To  
Notes
2020-07-06 15:44:01STILL NO LANDSCAPE PERMIT APPLIED FOR

Review Stop Z ZONING
Rev No 1 Status F Date 2020-04-29 Cont ID  
Sent By fmittner Date 2020-04-29 Time 15:39 Rev Time 0.00
Received By fmittner Date 2020-04-29 Time 15:39 Sent To  
Notes
2020-04-29 15:39:41NEED TO APPLY FOR SEPARATE LANDSCAPE PERMIT