| Plan Review Stops For Permit 20030916 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-11-19 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-11-19 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-10-14 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-10-14 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-20 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-20 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2020-07-20 09:29:11 | BUILDING PROVISO: | | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | 2017 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT | | | 561-805-6666. | | | | | | BUILDING PLAN REVIEW: JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-11-18 |
Time |
21:38 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-11-18 |
Time |
20:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-22 |
Time |
21:38 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-22 |
Time |
21:28 |
Sent To |
|
|
| Notes |
| 2020-10-22 21:38:43 | PREVIOUS ELECTRICAL COMMENTS WERE NOT ADDRESSED. NO | | | RESPONSE LETTER FOR ELECTRICAL WAS SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-01 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-01 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2020-08-01 17:58:33 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN STATES SEPARATE ELECTRICAL PLAN WILL BE | | | SUBMITTED BUT AN ELECTRICAL PLAN HAS BEEN UPLOADED FOR | | | REVIEW? PLEASE PROVIDE CLARIFICATION. BASED OFF PLAN | | | SUBMITTED THESE ARE THE COMMENTS FOR THAT PLAN. | | | | | | 2. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL OF FANS | | | (MUST BE WET LOCATION LISTED) FBC 107.2.1 NEC 110.2, | | | 110.3B | | | | | | 3. SHOW PANEL WHERE BRANCH CIRCUITS ORIGINATE FROM, | | | WIRE SIZE, OCP ETC. FBC 107.2.1 | | | | | | 4. PROVIDE LOAD CALCULATION FOR PANEL WHERE AWNING IS | | | BEING FED FROM FBC 107.2.1, NEC 225, 220 | | | | | | 5. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL OF STRING | | | LIGHTING. FBC 107.2.1 NEC 110.2 110.3B | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-21 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-07-21 15:07:20 | PROVISO COMMENTS: | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH | | | INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101. | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2013 EDITION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-11-19 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-11-19 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-05 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-10-13 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-24 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-16 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-11-19 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-22 |
Time |
21:39 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-22 |
Time |
21:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-08-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-01 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-01 |
Time |
17:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-11-18 |
Time |
16:10 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-11-18 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-11-04 |
Time |
15:27 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-11-04 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2020-11-04 15:27:52 | FAILED | | | | | | 1) REPEAT COMMENT. STRING LIGHTS ARE NOT PERMITTED FOR | | | COMMERCIAL USES BY THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS. THESE NEED TO BE REMOVED FROM | | | THE PLANS. | | | | | | 2) EXPOSED WIRING OR CONDUIT IS NOT PERMITTED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-08-24 |
Time |
14:29 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2020-08-24 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2020-08-24 14:29:18 | FAILED | | | | | | 1) STRING LIGHTS ARE NOT PERMITTED FOR COMMERCIAL USES | | | BY THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS. | | | THESE NEED TO BE REMOVED FROM THE PLANS. | | | | | | 2) EXPOSED WIRING OR CONDUIT IS NOT PERMITTED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|