Plan Review Details - Permit 20030675
Plan Review Stops For Permit 20030675
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-05-11 Cont ID  
Sent By ppetty Date 2020-05-11 Time 12:36 Rev Time 0.00
Received By ppetty Date 2020-05-11 Time 12:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-19 Cont ID  
Sent By jpearson Date 2020-03-19 Time 10:42 Rev Time 0.00
Received By ppetty Date 2020-03-19 Time 10:42 Sent To M
Notes
2020-03-19 10:43:39PLEASE SEE F/D NOTES

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-05-14 Cont ID  
Sent By pleduc Date 2020-05-14 Time   Rev Time 0.00
Received By pleduc Date 2020-05-14 Time 11:40 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-03-18 Cont ID  
Sent By bwoods Date 2020-03-18 Time 13:07 Rev Time 0.00
Received By sathomas Date 2020-03-18 Time 00:00 Sent To E
Notes
2020-03-18 13:07:151. NOTE#1: IS INCORRECT AS THE CANDELAS ARE NOT LISTED
 ON THE PLANS.
 2. BASED ON THE PLAN AND COVERAGE AREA PROVIDED,
 ADDITIONAL DEVICES MAY BE REQUIRED FOR VISUAL
 NOTIFICATION.
 3. SCOPE DICTATES SPRINKLER MONITORING SYSTEM, HOWEVER
 ALL OTHER NOTES INDICATE FIRE ALARM SYSTEM WITH VOICE
 COMMUNICATION. PLEASE INDICATE WHICH SYSTEM IS BEING
 INSTALLED, AND PROVIDE ACCURATE BATTERY AND BATTERY BOX
 INSTALLATION DIAGRAM.
 4. FIRE ALARM CIRCUIT BREAKER TO BE MARKED IN RED AND
 IDENTIFIED AS "FIRE ALARM." PROVIDE CIRCUIT BREAKER
 LOCK FOR DEDICATED BRANCH CIRCUIT.
 5. A CERTIFICATE OF COMPLETION AND A THIRD PARTY
 MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE SHALL
 BE PROVIDED AT TIME OF FINAL FIRE ALARM INSPECTION.
  
 S. THOMAS
 561-804-4728

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-16 Cont ID  
Sent By shill Date 2020-05-14 Time 12:39 Rev Time 0.00
Received By shill Date 2020-05-08 Time 16:27 Sent To  
Notes
2020-05-08 16:36:12ROUTED TO B11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-19 Cont ID  
Sent By hmoser Date 2020-03-19 Time 11:47 Rev Time 0.00
Received By hmoser Date 2020-03-13 Time 16:25 Sent To  
Notes
2020-03-13 16:25:51REVISION ROUTED TO FIRE INBOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-05-13 Cont ID  
Sent By hmoser Date 2020-05-13 Time 14:09 Rev Time 0.00
Received By hmoser Date 2020-05-13 Time 14:02 Sent To FIRE
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-03-19 Cont ID  
Sent By hmoser Date 2020-03-19 Time 11:46 Rev Time 0.00
Received By hmoser Date 2020-03-19 Time 11:27 Sent To I
Notes
2020-03-19 11:46:27PLAN FAIL SEE FIRE COMMENTS HM.