| Plan Review Stops For Permit 20030640 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-03-26 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-03-26 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2020-03-26 12:20:52 | CREATED NEW UNIT FOR KIOSK # 125 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-30 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-30 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-04-14 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-14 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2020-04-14 11:17:55 | KIOSK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) KIOSK DRAWINGS GL1 THROUGH GL13 - GENERAL NOTE | | | NUMBER 5 SAYS "PERIMETER FASTENERS SHALL BE AS NOTED | | | HEREON" . DRAWINGS DO NOT SHOW FASTENER TYPE, SIZE, | | | AMOUNT, ON CENTER SPACING ETC. THIS INFORMATION NEEDS | | | TO BE ON THE DRAWINGS. | | | 2) NEED COMPLETE (FRONT PAGES AND THE INSTALLATION | | | INSTRUCTIONS) COPIES OF THE PRODUCT APPROVALS THAT ARE | | | MENTIONED ON THE DRAWINGS. | | | 3) PLEASE REMOVE ALL NOTES THAT SAY "PRE FAB BUILDING" | | | FROM ALL DRAWINGS. | | | 4) KIOSK DRAWINGS GL1 THRU GL13 DO NOT SHOW AS | | | ELECTRONICALLY SIGNED IN "ADOBE". | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-26 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-26 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2020-03-26 15:47:45 | PRE FAB KIOSK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE STATE APPROVED MANUFACTURED BUILDING | | | DRAWINGS (MARKED REVIEWED AND APPROVED BY A 3RD PARTY) | | | OR PROVIDE A MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVAL FOR THE ENTIRE BUILDING. FBC WPB AMENDMENTS | | | 107.3 EXCEPTIONS. | | | 2) IF THE BUILDING IS BEING BUILT ON SITE THE DRAWINGS | | | WILL NEED TO SHOW ALL CONNECTIONS, COLUMN AND BEAM | | | DESIGNATIONS, PROVIDE ALL PRODUCT APPROVALS FOR ALL | | | STOREFRONT GLAZING, DOORS AND WINDOWS. | | | 3) DRAWING A1.1.1 SHOWS COUNTER HEIGHT AT 34 INCHES - | | | DRAWING A3.0.1 SHOWS COUNTER HEIGHT AT 36 INCHES - | | | PLEASE CLARIFY TO COMPLY WITH FBC ACCESSIBILITY. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-03-26 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-03-26 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-25 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-04-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-04-10 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-03-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-03-25 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-01 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-24 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-04-14 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-09 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-03-27 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-03-24 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-10 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-10 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-27 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-03-27 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2020-03-27 09:45:32 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT- 20030640 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED | | | | | | 1) PLEASE PROVIDE THE ENERGY GAUGE AND MANUAL S | | | CALCULATIONS. FBC EC 101.5.1.1.2 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-30 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-30 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-04-14 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-14 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2020-04-14 11:28:49 | THE GL DRAWINGS DO NOT SHOW IN "ADOBE" AS | | | ELECTRONICALLY SIGNED. DRAWINGS NEED TO BE | | | ELECTRONICALLY SIGNED TO BE USED IN ELECTRONIC PLAN | | | REVIEW. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-26 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-26 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2020-03-26 15:59:49 | THE ARCHITECTURAL AND THE GL DRAWINGS DO NOT SHOW IN | | | "ADOBE" AS ELECTRONICALLY SIGNED. DRAWINGS NEED TO BE | | | ELECTRONICALLY SIGNED TO BE USED IN ELECTRONIC PLAN | | | REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-07-01 |
Time |
08:52 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-07-01 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-04-10 |
Time |
16:59 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-04-10 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-03-27 |
Time |
16:00 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2020-03-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|