| Plan Review Stops For Permit 20030569 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-18 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-18 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2021-06-18 15:27:15 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | 4TH REVIEW | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ON THE ROOFING PRODUCT APPROVAL - PLEASE CIRCLE THE | | | SYSTEM TO BE USED - IF NEEDED ADDITIONAL ATTACHMENT | | | DETAILS MAY BE NEEDED FROM A DESIGN PROFESSIONAL FOR | | | ZONES 2 AND 3 REQUIRING HIGHER WIND PRESSURES THAN THE | | | PRODUCT APPROVAL WILL ALLOW ( SEE PRODUCT APPROVAL | | | LIMITATION NUMBER 5.7 IN THE PRODUCT APPROVAL). | | | 2) ROOFING SYSTEMS MAY BE DEFERRED SUBMITTALS BY | | | LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION | | | DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-16 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-16 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2021-02-16 09:20:07 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | 3RD REVIEW | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ROOFING PRODUCT APPROVAL FOR THIS ROUND OF REVIEW | | | DOES NOT INCLUDE THE INSTALLATION DETAILS ONLY THE | | | FRONT PAGES - PREVIOUS COMMENT = ON THE ROOFING PRODUCT | | | APPROVAL - PLEASE CIRCLE THE SYSTEM TO BE USED - IF | | | NEEDED PROVIDE SIGNED AND SEALED ADDITIONAL ATTACHMENT | | | DETAILS FROM AN ENGINEER OR ARCHITECT FOR ZONES 2 AND 3 | | | REQUIRING HIGHER WIND PRESSURES THAN THE PRODUCT | | | APPROVAL WILL ALLOW ( SEE LIMITATION NUMBER 7 IN THE | | | PRODUCT APPROVAL). | | | 2) ROOFING SYSTEMS MAY BE DEFERRED SUBMITTALS BY | | | LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION | | | DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-15 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-15 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2020-10-15 08:11:03 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | 2ND REVIEW | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DESIGN NEEDS TO BE BASED ON 2017 FBC (DRAWINGS SHOW | | | 2014 FBC ) | | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS AND DOORS. | | | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD. | | | 3) ON THE ROOFING PRODUCT APPROVAL - PLEASE CIRCLE THE | | | SYSTEM TO BE USED - IF NEEDED PROVIDE SIGNED AND SEALED | | | ADDITIONAL ATTACHMENT DETAILS FROM AN ENGINEER OR | | | ARCHITECT FOR ZONES 2 AND 3 REQUIRING HIGHER WIND | | | PRESSURES THAN THE PRODUCT APPROVAL WILL ALLOW ( SEE | | | LIMITATION NUMBER 7 IN THE PRODUCT APPROVAL). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-24 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-24 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2020-03-24 17:01:27 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DESIGN NEEDS TO BE BASED ON 2017 FBC (DRAWINGS SHOW | | | 2014 FBC ) | | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS AND DOORS. | | | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD. | | | 3) ON THE ROOFING PRODUCT APPROVAL - PLEASE CIRCLE THE | | | SYSTEM TO BE USED - IF NEEDED PROVIDE SIGNED AND SEALED | | | ADDITIONAL ATTACHMENT DETAILS FROM AN ENGINEER OR | | | ARCHITECT FOR ZONES 2 AND 3 REQUIRING HIGHER WIND | | | PRESSURES THAN THE PRODUCT APPROVAL WILL ALLOW ( SEE | | | LIMITATION NUMBER 7 IN THE PRODUCT APPROVAL). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-06 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-06 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-19 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-19 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:17:49 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) ADDITION SHOWS ONLY A WINDOW A/C UNIT, YOU NEED TO | | | SHOW ALL OUTLETS AND LIGHT CONTROLED BY A SWITCH. ROOM | | | MAY NEED SMOKE ALARM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-27 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-03-27 |
Time |
15:31 |
Sent To |
I |
|
| Notes |
| 2020-03-27 16:15:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1) THE NEC AND FBC SPECIFIED FOR DESIGN IS NOT THE | | | CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE | | | CURRENT CODES ABOVE). | | | | | | 2) THE ARCHITECT'S SIGNATURE APPEARS TO BE A | | | COPY/FACSIMILE. THE ARCHITECT'S ORIGINAL HANDWRITTEN | | | SIGNATURE IS REQUIRED ON THESE DRAWINGS. | | | 61G1-16.003 USE OF SEAL. | | | (1) THE PERSONAL SEAL, SIGNATURE AND DATE OF THE | | | ARCHITECT OR INTERIOR DESIGNER SHALL APPEAR ON ALL | | | ARCHITECTURAL OR INTERIOR DESIGN DOCUMENTS TO BE FILED | | | FOR PUBLIC RECORD AND SHALL BE CONSTRUED TO OBLIGATE | | | HIS PARTNERS OR HIS CORPORATION. A CORPORATE SEAL ALONE | | | IS INSUFFICIENT. DOCUMENTS SHALL BE SIGNED PERSONALLY | | | AND SEALED BY THE RESPONSIBLE ARCHITECT OR INTERIOR | | | DESIGNER. FINAL OFFICIAL RECORD DOCUMENTS (NOT | | | TRACINGS, ETC.) SHALL BE SO SIGNED. THE SIGNING AND | | | SEALING OF THE SPECIFICATION INDEX SHEETS SHALL BE | | | CONSIDERED ADEQUATE. ALL DRAWING SHEETS AND PAGES SHALL | | | BE SO SIGNED AND SEALED. AN ARCHITECT OR INTERIOR | | | DESIGNER SHALL NOT AFFIX, OR PERMIT TO BE AFFIXED, HIS | | | SEAL OR NAME TO ANY PLAN, SPECIFICATIONS, DRAWINGS, OR | | | OTHER RELATED DOCUMENT WHICH WAS NOT PREPARED BY HIM OR | | | UNDER HIS RESPONSIBLE SUPERVISING CONTROL AS PROVIDED | | | IN RULE CHAPTER 61G1-23, F.A.C. AN ARCHITECT OR | | | INTERIOR DESIGNER SHALL NOT USE HIS SEAL OR DO ANY | | | OTHER ACT AS AN ARCHITECT OR INTERIOR DESIGNER UNLESS | | | HOLDING AT THE TIME A CERTIFICATE OF REGISTRATION AND | | | ALL REQUIRED RENEWALS THEREOF. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | ROBERT MCDOUGAL | | | COMBINATION PLANS EXAMINER | | | 561-805-6714 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-07 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-07 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-24 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-26 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-24 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-06 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-25 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-11-15 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-09-30 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-27 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-03-11 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-10-02 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-10-02 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2020-10-02 08:30:22 | OK-PLANS STAMPED AND SENT STORGE | | | REVIEW 18-22777 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-25 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-25 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-03-25 08:18:48 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-01 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-01 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-17 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-03-17 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-04 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-04 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-03 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-03 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2021-02-03 12:37:19 | 3RD REVIEW FBC-2017 RES. PLUMBING | | | PERMIT #20030569 | | | 2/3/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE ARCHITECT'S RESPONSE INDICATES "NO PLUMBING WORK IN | | | THIS PHASE OF WORK" HOWEVER THE REVISED PLANS ARE | | | LABELED "AS BUILT" PLEASE PROVIDE AN ITEMIZED SCOPE OF | | | "AS BUILT" PLUMBING WORK OR PLACE A NOTE ON THE PLAN | | | THAT NO PLUMBING WORK HAVE BEEN PERFORMED. PLEASE NOTE | | | THE PLAN REVISED ENERGY CALCULATION FORM INDICATES A | | | NEW WATER HEATER. PLEASE INCLUDE THAT IN THE SCOPE OF | | | WORK AND PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN. | | | | | | COMMENTS #4 & #5 FROM THE 1ST AND 2ND REVIEWS LISTED | | | BELOW STILL EXIST. | | | | | | 4) THE PROJECT ADDRESS ON THE AC CALCULATIONS- 1019 | | | SOUTH MANGONIA CIRCLE- DOES NOT MATCH THE PROJECT | | | ADDRESS ON THE PERMIT APPLICATION AND PLANS- SECTION | | | 107.2.1 WPB. | | | | | | 5) THE $1800.00 VALUE ON THE PERMIT APPLICATION APPEARS | | | VERY LOW FOR THE PROPOSED SCOPE OF WORK SHOWN ON THE | | | PLANS. PLEASE PROVIDE COPIES OF SIGNED CONTRACTS AND/OR | | | ESTIMATES, INVOICES ETC. TO VERIFY THE TOTAL COST OF | | | CONSTRUCTION INCLUDING BUILDING, MECHANICAL, | | | ELECTRICAL, PLUMBING, DESIGN FEES AND SITE WORK- | | | SECTION 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-10-02 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-10-02 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2020-10-02 08:13:05 | 2ND REVIEW FBC-2017 RES. PLUMBING | | | PERMIT #20030569 | | | 3/26/20 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENTS #1, 4, & 5 FROM THE 1ST REVIEW LISTED BELOW | | | STILL EXIST. NO RESPONSES TO THE PLUMBING COMMENTS WAS | | | PROVIDED WITH THE RESUBMITTED PLANS. | | | | | | 1) PROVIDE PLUMBING PLANS INCLUDING A SCOPE OF WORK | | | OUTLINE INDICATING WHAT PLUMBING WORK WAS PERFORMED, | | | SUCH AS PLUMBING WORK ASSOCIATED WITH KITCHEN AND BATH | | | REMODELING- SECTION 107.2.1 WPB. PLEASE INCLUDE A | | | SANITARY ISOMETRIC DRAWING FOR ALL NEW DRAIN AND VENT | | | INSTALLATIONS OR ALTERATIONS- SECTION P3005.4 FBC RES. | | | | | | 4) THE PROJECT ADDRESS ON THE AC CALCULATIONS- 1019 | | | SOUTH MANGONIA CIRCLE- DOES NOT MATCH THE PROJECT | | | ADDRESS ON THE PERMIT APPLICATION AND PLANS- SECTION | | | 107.2.1 WPB. | | | | | | 5) THE $1800.00 VALUE ON THE PERMIT APPLICATION APPEARS | | | VERY LOW FOR THE PROPOSED SCOPE OF WORK SHOWN ON THE | | | PLANS. PLEASE PROVIDE COPIES OF SIGNED CONTRACTS AND/OR | | | ESTIMATES, INVOICES ETC. TO VERIFY THE TOTAL COST OF | | | CONSTRUCTION INCLUDING BUILDING, MECHANICAL, | | | ELECTRICAL, PLUMBING, DESIGN FEES AND SITE WORK- | | | SECTION 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-26 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-26 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2020-03-26 16:50:07 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT #20030569 | | | 3/26/20 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE PLUMBING PLANS INCLUDING A SCOPE OF WORK | | | OUTLINE INDICATING WHAT PLUMBING WORK WAS PERFORMED, | | | SUCH AS PLUMBING WORK ASSOCIATED WITH KITCHEN AND BATH | | | REMODELING- SECTION 107.2.1 WPB. PLEASE INCLUDE A | | | SANITARY ISOMETRIC DRAWING FOR ALL NEW DRAIN AND VENT | | | INSTALLATIONS OR ALTERATIONS- SECTION P3005.4 FBC RES. | | | | | | 2) THE ENERGY COMPLIANCE FORM R405-2017 INDICATES A NEW | | | WATER HEATER WAS INSTALLED. PLEASE SHOW THE LOCATION OF | | | THE WATER HEATER AND SUBMIT A SPEC SHEET. | | | | | | 3) PROVIDE A DUPLICATE COPY OF THE THE ENERGY FORM | | | R405-2017- SECTION 107.2.1 WPB. | | | | | | 4) THE PROJECT ADDRESS ON THE AC CALCULATIONS- 1019 | | | SOUTH MANGONIA CIRCLE- DOES NOT MATCH THE PROJECT | | | ADDRESS ON THE PERMIT APPLICATION AND PLANS- SECTION | | | 107.2.1 WPB. | | | | | | 5) THE $1800.00 VALUE ON THE PERMIT APPLICATION APPEARS | | | VERY LOW FOR THE PROPOSED SCOPE OF WORK SHOWN ON THE | | | PLANS. PLEASE PROVIDE COPIES OF SIGNED CONTRACTS AND/OR | | | ESTIMATES, INVOICES ETC. TO VERIFY THE TOTAL COST OF | | | CONSTRUCTION INCLUDING BUILDING, MECHANICAL, | | | ELECTRICAL, PLUMBING, DESIGN FEES ANSD SITE WORK- | | | SECTION 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
P |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-13 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-13 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-24 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-24 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2021-08-24 11:51:30 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = NEED TO | | | CHOOSE A ROOFING SYSTEM IN THE PRODUCT APPROVAL (FROM | | | PAGE 8 TO PAGE18) THAT SHOWS THE REQUIRED WIND DESIGN | | | PRESSURE OF (108 PSF PER FBC R TABLE 301.2 (2)) - | | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | | PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE ADDITIONAL | | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | | THE ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A HIGHER WIND | | | PRESSURE THEN THE CHOSEN ROOFING SYSTEM - SEE GENERAL | | | LIMITATION NOTES ON THE PRODUCT APPROVAL. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-18 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-18 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2021-06-18 15:28:41 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | 4TH REVIEW | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ON THE ROOFING PRODUCT APPROVAL - PLEASE CIRCLE THE | | | SYSTEM TO BE USED - IF NEEDED ADDITIONAL ATTACHMENT | | | DETAILS MAY BE NEEDED FROM A DESIGN PROFESSIONAL FOR | | | ZONES 2 AND 3 REQUIRING HIGHER WIND PRESSURES THAN THE | | | PRODUCT APPROVAL WILL ALLOW ( SEE PRODUCT APPROVAL | | | LIMITATION NUMBER 5.7 IN THE PRODUCT APPROVAL). | | | 2) ROOFING SYSTEMS MAY BE DEFERRED SUBMITTALS BY | | | LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION | | | DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-16 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-16 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2021-02-16 09:22:49 | SEE BUILDING PLAN REVIEW | | | A BUILDING PERMIT APPLICATION MARKED ROOFING IS | | | REQUIRED. | | | ROOFING SYSTEMS MAY BE DEFERRED SUBMITTALS BY LISTING | | | ITEMS TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-10-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-15 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-15 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2020-10-15 08:11:38 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-25 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-25 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-03-25 08:19:53 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-01 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-01 |
Time |
06:40 |
Sent To |
|
|
| Notes |
| 2021-02-01 06:42:55 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-10-02 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-10-02 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2020-10-02 08:31:12 | ORIGINAL TO STORAGE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-12-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-12-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2021-08-23 |
|
|
Cont ID |
|
| Sent By |
awwoten |
Date |
2021-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-08-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-08-23 14:43:30 | *****************ZONING REVIEW | | | FAILED********************* | | | | | | | | | PROVIDE A SITE PLAN/ SURVEY WITH THE LOCATION OF THE | | | PROPOSED ADDITION AND THE SETBACKS TO THE PROPERTY | | | LINES. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-11-12 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-11-12 |
Time |
12:53 |
Sent To |
I |
|
| Notes |
| 2020-11-12 13:07:19 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED | | | ________________________________________ | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-16 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2020-03-16 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2020-03-16 |
Time |
15:47 |
Sent To |
I |
|
| Notes |
| 2020-03-16 15:48:15 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 03/16/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A SURVEY OF THE SUBJECT SITE WITH THE | | | LOCATION OF THE PROPOSED ADDITION AND ITS SETBACKS TO | | | THE PROPERTY LINES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|