Plan Review Details - Permit 20030294
Plan Review Stops For Permit 20030294
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-06-30 Cont ID  
Sent By pvalenti Date 2020-06-30 Time 09:40 Rev Time 0.00
Received By pvalenti Date 2020-06-30 Time 09:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By jwitmer Date 2020-06-02 Time 16:30 Rev Time 0.00
Received By jwitmer Date 2020-06-02 Time 15:44 Sent To  
Notes
2020-06-02 16:28:552017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20030294
 ADD: 1401 VILLAGE BLVD. BUILDING # 3
 CONT: SENTINEL DEVELOPMENT GROUP
 TEL: 561-373-4056
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JUNE 02ND/ 2020
 ACTION: DENIED
  
 1) SHEET 1 OF 1 BY EDGAR V. DUENAS P. E. # 57831
 APPEARS TO HAVE BEEN A PAPER DOCUMENT THAT WAS SIGNED
 AND SEALED, THEN UP-LOADED TO BE A DIGITAL DOCUMENT.
  
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 DIGITALLY SIGNED AND SEALED ENGIN20040980EERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 2) SHEET 1 OF 1 UNDER THE HEADING OF STRUCTURAL NOTES
 (B) FIRST FLOOR LIVE LOADS BALCONIES LISTED AS 50 PSF.
 THE PLANS ARE SILENT AS TO THE LIVE LOADS FOR THE 2ND
 FLOOR NOR IS THERE THE LIVE LOADS FOR STAIRWAYS. PLEASE
 REFER TO THE 2017 FBC-B TABLE 1607.1 (30) STAIRS &
 EXITS. 100 PSF. THE PERMIT APPLICATION UNDER THE
 HEADING SCOPE OF WORK THE LINE IS LEFT BLANK. PLEASE
 IDENTIFY THE SCOPE OF WORK, IS THIS A REPAIR OF THE
 EXTERIOR STAIR WALL AND STAIR? OR IS THIS A REPAIR OF
 THE EXTERIOR STAIR WALL? THERE IS ONE NOTE THAT THE
 STAIR IS A STEEL STAIR IS THIS CORRECT?
  
 3) THE SHEET 1 OF 1 INDICATES THIS IS A LEVEL 1
 ALTERATION. I BELIEVE THAT MORE THAN JUST THE FINISHES
 ARE BEING REPLACED MAKING THIS A REPAIR UNDER THE 2017
 EXISTING BUILDING CODE, SEE SECTION 606.1 STRUCTURAL
 REPAIRS. .
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-06 Cont ID  
Sent By pvalenti Date 2020-07-06 Time 14:18 Rev Time 0.00
Received By pvalenti Date 2020-06-29 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-04 Cont ID  
Sent By lmarchan Date 2020-06-04 Time 09:22 Rev Time 0.00
Received By lmarchan Date 2020-05-27 Time 09:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-06-30 Cont ID  
Sent By pvalenti Date 2020-06-30 Time 09:40 Rev Time 0.00
Received By pvalenti Date 2020-06-30 Time 09:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-02 Cont ID  
Sent By jwitmer Date 2020-06-02 Time 16:29 Rev Time 0.00
Received By jwitmer Date 2020-06-02 Time 15:45 Sent To  
Notes
2020-06-02 16:29:19SHEET 1 OF 1 BY EDGAR V. DUENAS P. E. # 57831 APPEARS
 TO HAVE BEEN A PAPER DOCUMENT THAT WAS SIGNED AND
 SEALED, THEN UP-LOADED TO BE A DIGITAL DOCUMENT.
  
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 DIGITALLY SIGNED AND SEALED ENGIN20040980EERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-07-02 Cont ID  
Sent By rthermid Date 2020-07-02 Time   Rev Time 0.00
Received By rthermid Date 2020-07-02 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-06-03 Cont ID  
Sent By rthermid Date 2020-06-03 Time   Rev Time  
Received By rthermid Date 2020-06-03 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy