Plan Review Details - Permit 20030157
| Plan Review Stops For Permit 20030157 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-28 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-28 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2020-07-28 10:09:23 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING A300 SHOWS CEILING HEIGHT AT 6 FOOT 8 | | | INCHES. PLEASE SHOW CEILING HEIGHT TO COMPLY WITH FBC | | | R305.1 (SPACE IS HABITABLE MINIMUM CEILING HEIGHT 7 | | | FEET) | | | 2) PLEASE SHOW CEILING INSULATION TYPE AND "R" VALUE. | | | FBC ENERGY R401.1 | | | 3) DRAWING A300 SHOWS SOFFIT SCREEN VENT AT 8-FOOT OC. | | | SHOULD BE A CONTINUOUS SCREEN VENT FOR ENCLOSED RAFTER | | | SPACES FBC R806 | | | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR DOOR AND WINDOWS. | | | 5) PLEASE SHOW THE BUILDING SET BACK FROM THE PROPERTY | | | LINE AT THE NORTH EAST CORNER OF THE BUILDING. FBC | | | TABLE R302.1 (NEEDED TO DETERMINE THE FIRE RATING - IF | | | ANY) | | | 6) SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-17 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2020-03-17 10:31:47 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE WIND LOAD CALCULATIONS BASED ON WIND | | | SPEED OF 170MPH OR SIGNED AND SEALED DETAILS FROM AN | | | ARCHITECT OR ENGINEER TO COMPLY WITH THE WIND LOAD | | | REQUIREMENTS FBC R301.2.1.1 | | | 2) PLEASE SHOW WALL FRAMING AND CLADDING DETAILS TO | | | COMPLY WITH THE WIND LOADS PER FBC R301.2.1.1 | | | 3) PLEASE SHOW ALL HURRICANE STRAPPING AND STRAP | | | NAILING REQUIREMENTS FBC R602.3.5 | | | 4) PLEASE SHOW CEILING HEIGHT TO COMPLY WITH FBC R305.1 | | | 5) PLEASE SHOW WALL AND CEILING INSULATION TYPE AND "R" | | | VALUE. FBC ENERGY R401.1 | | | 6) PLEASE PROVIDE A CLEAR FLOOR PLAN SHOWING THE ROOM | | | USE, ROOM DIMENSIONS, SIZE AND LOCATION OF WINDOWS, | | | SIZE AND LOCATION OF DOORS ETC. | | | 7) FOR BEDROOMS PLEASE SHOW THE EMERGENCY EGRESS TO | | | COMPLY WITH FBC R310 | | | 8) PLEASE SHOW ALL EXISTING ELEMENTS AND ATTACHMENTS OF | | | NEW WORK TO EXISTING ELEMENTS ( ROOF, FOUNDATION, | | | COLUMNS, BEAMS, ETC.). FBC WPB AMENDMENTS 107 | | | 9) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR DOOR AND WINDOWS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-30 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-30 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2020-07-30 11:37:29 | PLAN REVIEW - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST ELECTRICAL REVIEW HAVE NOT BEEN | | | ADDRESSED. I HAVE ATTACHED THEM HERE FOR YOUR REVIEW. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1) PLANS ARE ILLEGIBLE. THE SUBMITTED FLOOR PLAN IS | | | UNACCEPTABLE. PLEASE REVIEW THE FOLLOWING SECTIONS FROM | | | THE WEST PALM BEACH AMENDMENTS TO THE FBC: FBC 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED | | | WHEN APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | 3) THE $1500.00 VALUE IS TOO LOW. THE VALUE USED FOR | | | PERMITTING IS THE COMPLETE REPLACEMENT COST FOR ALL | | | MATERIALS AND LABOR. FBC 109.3 BUILDING PERMIT | | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | 4) PROVIDE ELECTRICAL PLAN FOR REVIEW THAT IS DESIGNED | | | BY AND SIGNED AND SEALED BY A LICENSED DESIGN | | | PROFESSIONAL OR DESIGNED BY AND SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | 5) PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS, OR PROVIDE A NOTE REQUIRING | | | COMPLIANCE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | | | 6) PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | | | | 7) PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 8) PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; WPB FBC 107.2.1 | | | | | | 9) SHOW THE LOCATIONS OF THE EXISTING SERVICE RISER AND | | | PANEL ON THE FLOOR PLANS. WPB FBC 107.2.1 | | | | | | 10) PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | | | | 11) ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | NOTE ON PLANS. NEC 210.12; FBC RE E3902.16 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | ROBERT MCDOUGAL | | | COMBINATION PLANS EXAMINER | | | 561-805-6714 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-03-25 |
Time |
17:49 |
Sent To |
I |
|
| Notes |
| 2020-03-25 18:15:41 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1) PLANS ARE ILLEGIBLE. THE SUBMITTED FLOOR PLAN IS | | | UNACCEPTABLE. PLEASE REVIEW THE FOLLOWING SECTIONS FROM | | | THE WEST PALM BEACH AMENDMENTS TO THE FBC: FBC 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED | | | WHEN APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | 3) THE $1500.00 VALUE IS TOO LOW. THE VALUE USED FOR | | | PERMITTING IS THE COMPLETE REPLACEMENT COST FOR ALL | | | MATERIALS AND LABOR. FBC 109.3 BUILDING PERMIT | | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | 4) PROVIDE ELECTRICAL PLAN FOR REVIEW THAT IS DESIGNED | | | BY AND SIGNED AND SEALED BY A LICENSED DESIGN | | | PROFESSIONAL OR DESIGNED BY AND SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | 5) PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS, OR PROVIDE A NOTE REQUIRING | | | COMPLIANCE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | | | 6) PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | | | | 7) PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 8) PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; WPB FBC 107.2.1 | | | | | | 9) SHOW THE LOCATIONS OF THE EXISTING SERVICE RISER AND | | | PANEL ON THE FLOOR PLANS. WPB FBC 107.2.1 | | | | | | 10) PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | | | | 11) ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | NOTE ON PLANS. NEC 210.12; FBC RE E3902.16 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | ROBERT MCDOUGAL | | | COMBINATION PLANS EXAMINER | | | 561-805-6714 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-30 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-09 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-03-04 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-17 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2020-03-17 10:33:31 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-20 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-20 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2020-07-20 13:05:51 | PLEASE RESPOND TO THE 1ST CYCLE REVIEW COMMENTS. WE | | | MUST SEE HOW THIS NEW ADDITION WILL BE CONDITIONED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-13 |
Time |
13:33 |
Rev Time |
|
| Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-03-13 13:35:53 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT 20030157 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THIS PROJECT APPEARS TO BE ADDING ADDITIONAL | | | CONDITIONED SQUARE FOOTAGE. PLEASE PROVIDE THE REQUIRE | | | INFORMATION ON THESE PLANS. SHOW WHERE THE HVAC SYSTEM | | | IS LOCATED FOR THIS ADDITION. ATTACH SPEC SHEETS FOR | | | THIS SYSTEM. PROVIDE SPEC SHEETS FOR THE BATH EXHAUST | | | FAN. SHOW LOCATION OF EXHAUST TERMINATION. SHOW | | | LOCATION OF CONDENSING UNIT. PROVIDE ENERGY | | | CALCULATIONS FOR THIS ADDITION. | | | SEE FBC EC R103.2 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DRAWN TO SCALE UPON | | | SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHERE APPROVED BY THE CODE | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED, AND SHOW IN SUFFICIENT DETAIL | | | PERTINENT DATA AND FEATURES OF THE BUILDING, SYSTEMS | | | AND EQUIPMENT AS HEREIN GOVERNED. DETAILS SHALL | | | INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING AS | | | APPLICABLE: | | | 1.INSULATION MATERIALS AND THEIR R-VALUES. | | | 2.FENESTRATION U-FACTORS AND SOLAR HEAT GAIN | | | COEFFICIENTS (SHGC). | | | 3.AREA-WEIGHTED U-FACTOR AND SOLAR HEAT GAIN | | | COEFFICIENTS (SHGC) CALCULATIONS. | | | 4.MECHANICAL SYSTEM DESIGN CRITERIA. | | | 5.MECHANICAL AND SERVICE WATER-HEATING SYSTEM AND | | | EQUIPMENT TYPES, SIZES AND EFFICIENCIES. | | | 6.EQUIPMENT AND SYSTEM CONTROLS. | | | 7.DUCT SEALING, DUCT AND PIPE INSULATION AND LOCATION. | | | 8.AIR SEALING DETAILS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-21 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-21 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2020-07-21 10:17:38 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT #20030157 | | | 7/21/20 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENT #6 FROM THE 1ST REVIEW PRINTED BELOW WAS NOT | | | ADDRESSED- PLEASE COMPLY. | | | | | | 6) THE $1500.00 COST ON THE PERMIT APPLICATION IS | | | UNDERVALUED FOR THE ENTIRE SCOPE OF THE PROJECT THAT | | | INCLUDES BUILDING, MECHANICAL, ELECTRICAL, AND | | | PLUMBING. PLEASE NOTE THAT PERMIT VALUE IS BASED ON | | | LABOR, MATERIALS, FIXTURES, APPLIANCES, EQUIPMENT AND | | | DESIGN FEES FOR ALL PHASES OF CONTRUCTION. PLEASE | | | PROVIDE COPIES OF SIGNED CONTRACTS AND/OR ESTIMATES, | | | INVOICES VERIFYING TOTAL VALUE OF THE PROJECT- SECTION | | | 109.3 WPB AMENDMENTS TO THE FBC-17. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICA/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-25 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-25 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2020-03-25 12:55:57 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT #20030157 | | | 3/25/20 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A SCOPE OF WORK FOR PLUMBING | | | ALTERATIONS, AND CORRELATING DRAWINGS AND DETAILS ON A | | | SEPARATE PLAN SHEET. PROVIDE A DIMENSIONED FLOOR PLAN | | | DRAWING FOR THE BATHROOM SHOWING LOCATIONS OF THE | | | FIXTURES AND REQUIRED FIXTURE CLEARANCES PER FIGURE | | | R307.1 FBC RES. THE PLAN SHALL BE PREPARED BY, AND BEAR | | | THE SIGNATURE OF THE PLUMBING SUB-CONTRACTOR OF RECORD, | | | OR CAN BE PREPARED BY A FL. LICENSED ARCHITECT OR | | | ENGINEER IN ACCORDANCE WITH SECTIONS 107.1 & 107.2.1 | | | WPB. | | | | | | 2) REFER TO SECTION R2708.4 FBC RES AND PLACE A NOTE ON | | | THE PLAN INDICATING THE SHOWER WILL BE EQUIPPED WITH | | | EITHER A PRESSURE-BALANCED THERMOSTSATIC-MIXING OR | | | COMBINATION PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE | | | TYPE WITH A HIGH LIMIT STOP. SPECS (CUTSHEET) FOR THE | | | VALVE MAY BE SUBMITTED WITH THE CORRECTED PLAN OR | | | AVAILABLE ONSITE FOR INSPECTION. | | | | | | 3) FOR ONSITE CONSTRUCTED SHOWER PANS REFER TO SECTION | | | R2709.1 THROUGH P2709.4 FBC RES AND PROVIDE SHOWER | | | RECEPTOR SLOPING AND LINING DETAILS. | | | | | | 4) REFER TO SECTION R307.2 FBC RES AND INDICATE HOW THE | | | SHOWER FLOOR AND WALLS WILL BE FINISHED. | | | | | | 5) PROVIDE A CORRECTED AND CLEAR SANITARY ISOMETRIC ON | | | THE NEW PLAN THAT SHOWS THE REQUIRED DRAINAGE AND VENT | | | PIPES SIZES FOR THE FIXTURES- SECTIONS P3005.1 AND | | | P3105.1 FBC RES. FOR TYPICAL WET VENT REQUIREMENTS SEE | | | SECTION P3108.1 FBC RES. | | | | | | 6) THE $1500.00 COST ON THE PERMIT APPLICATION IS | | | UNDERVALUED FOR THE ENTIRE SCOPE OF THE PROJECT THAT | | | INCLUDES BUILDING, MECHANICAL, ELECTRICAL, AND | | | PLUMBING. PLEASE NOTE THAT PERMIT VALUE IS BASED ON | | | LABOR, MATERIALS, FIXTURES, APPLIANCES, EQUIPMENT AND | | | DESIGN FEES FOR ALL PHASES OF CONTRUCTION. PLEASE | | | PROVIDE COPIES OF SIGNED CONTRACTS AND/OR ESTIMATES, | | | INVOICES VERIFYING TOTAL VALUE OF THE PROJECT- SECTION | | | 109.3 WPB AMENDMENTS TO THE FBC-17. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICA/PLUMBINGL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-28 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-17 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-03-17 10:34:20 | SEE BUILDING COMMENTS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-28 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2020-07-28 10:28:51 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2020-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2020-07-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-17 08:42:25 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE PROPOSED TERRACE ENCLOSURE DOES NOT MEET THE | | | MINIMUM BUILDING SIDE SETBACK OF 5 FT. AND THEREFORE, | | | THE EXISTING TERRACE CANNOT BE ENCLOSED. [3/13/2020 | | | REPEAT COMMENT - DUE TO THE QUALITY OF THE SCANNED | | | PLANS, STAFF CANNOT CONFIRM IF CHANGES HAD BEEN MADE TO | | | ADDRESS THIS COMMENT.] | | | | | | 2.) THE QUALITY OF THE SCANNED PLANS IS NOT GOOD, WHICH | | | MAKES THE INFORMATION IN THE SITE PLAN, ARCHITECTURAL | | | PLANS, ETC. DIFFICULT TO REVIEW FOR COMPLIANCE WITH THE | | | ZONING CODE. PLEASE ADDRESS. | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2020-03-13 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2020-03-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-03-13 16:09:03 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE PROPOSED TERRACE ENCLOSURE DOES NOT MEET THE | | | MINIMUM BUILDING SIDE SETBACK OF 5 FT. AND THEREFORE, | | | THE EXISTING TERRACE CANNOT BE ENCLOSED. | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
|