| Plan Review Stops For Permit 20030124 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-07-08 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-07-08 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-03-05 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-03-05 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2020-03-05 13:33:32 | PLEASE PROVIDE SITE PLAN, SHOWING ENTRANCES TO | | | DIFFERENT UNITS, INCLUDING LAYOUT FOR 1ST AND 2ND | | | FLOOR. PLEASE CONTACT [email protected] |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2020-04-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-06 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-06 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-03-11 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-03-11 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2020-03-11 18:43:40 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-04-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-04-09 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-04-09 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-06 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-06 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2020-04-06 10:39:39 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING PLAN REVIEW DENIED: | | | | | | FBC B 107.2.2, AS PER LAST BUILDING REVIEW ITEM #5; THE | | | INFORMATION ON SHEET G-103B NEEDS TO BE CORRECTED. | | | PLEASE CHANGE THE CONSTRUCTION TYPE LISTED IN TYPES OF | | | CONSTRUCTION (A) CH.6, LAST COLUMN AT TOP ROW SHOWS | | | TYPE 2B. THE FIRST COLUMN SHOWS TYPE 1B, THESE TWO | | | COLUMNS NEED TO MATCH. | | | | | | | | | | | | | | | NOTE: AS PER LAST REVIEW, NO RESPONSE NEEDED FOR | | | PROVISOS THEY WILL BE | | | ADDED TO PLANS BEFORE BEING ISSUED. | | | | | | A) PROVIDE PRODUCT APPROVAL FOR ROOF HATCH AND LADDER | | | WITH 16 SQ. FT MINUMUM OPENING | | | AS REQUIRED BY FBC 1011.12 AND 1011.12.1 | | | | | | B) ENGINEERING FOR HANDRAILS AND GUARDRAILS. | | | | | | C) SUBMITTAL TO INCLUDE ANY PRODUCT APPROVALS INCLUDING | | | WINDOWS, STOREFRONT AND DOORS. | | | | | | D) ROOFING PRODUCT APPROVALS TO BE SUBMITTED WITH SUB | | | PERMIT APPLICATION. | | | | | | E) I) AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED | | | PRIOR TO C.O. | | | | | | CONTACT WITHIN 90 DAYS OF PERMIT ISSUANCE. | | | F) 5) CONSTRUCTION HOURS ? 7AM TO 7PM MON?FRI, 8AM TO | | | 8PM SAT?SUN | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-03-10 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-03-10 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2020-03-10 11:06:26 | REVIEW COMMENTS FOR ANCHOR SPACES: | | | 1) 708.6 FBC{B]SHEET A-101 NOTE A51 STATES EXISTING TO | | | REMAIN. PLEASE STATE THE FIRE RATING OF THIS DOOR AS IT | | | IS IN A FIRE PARTITION SEPARATING THE TENANT SPACES. | | | | | | 2) 708.1 FBC[B]SHOW 1 HOUR FIRE SEPARATIONS OF TENANT | | | SPACES. | | | | | | 3) STATE ON DATA SHEET THE PREVIOUS OCCUPANCY OF ANCHOR | | | SPACES. | | | | | | 4) PROVIDE BREAKDOWN OF SQUARE FOOTAGES OF EACH SPACE. | | | | | | 5) SHEET G-103B PLEASE CHANGE THE CONSTRUCTION TYPE | | | LISTED IN -TYPES OF CONSTRUCTION-(A) CH. 6- LAST COLUMN | | | TO TOP ROW SAYS TYPE 2B. | | | MATCH THE TYPE STATED ON THE FIRST COLUMN (TYPE 1-B) | | | | | | 6) 705.8 TABLE FBC[B]SHOW FIRE SEPARATION BETWEEN THE | | | NEW PARKING GARAGE AND EXISTING STRUCTURE TO THE SOUTH. | | | USE BUILDING TO PROPERTY LINES AS THE SEPARATION | | | DISTANCE. STATE THE ALLOWABLE AREA OF OPENINGS BASED ON | | | THE SEPARATION DISTANCE. | | | | | | 7) 1011.12 FBC[B]SHEET A-106 SHOWS ROOF HATCH AT 3 FEET | | | BY 3 FEET. SEE FBC 1011.12 AND 1011.12.1 FOR REQUIRED | | | SIZE OF ROOF HATCH. | | | | | | PROVISOS: NO RESPONSE NEEDED FOR PROVISOS THEY WILL BE | | | ADDED TO PLANS BEFORE BEING ISSUED. | | | A) PROVIDE PRODUCT APPROVAL FOR ROOF HATCH AND LADDER | | | WITH 16 SQ. FT MINUMUM OPENING | | | AS REQUIRED BY FBC 1011.12 AND 1011.12.1 | | | B) ENGINEERING FOR HANDRAILS AND GUARDRAILS. | | | C) SUBMITTAL TO INCLUDE ANY PRODUCT APPROVALS INCLUDING | | | WINDOWS, STOREFRONT AND DOORS. | | | D) ROOFING PRODUCT APPROVALS TO BE SUBMITTED WITH SUB | | | PERMIT APPLICATION. | | | E) I) AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED | | | PRIOR TO C.O. | | | CONTACT WITHIN 90 DAYS OF PERMIT ISSUANCE. | | | F) 5) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO | | | 8PM SAT-SUN | | | | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-03-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-11 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-11 |
Time |
07:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-03-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-03-26 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-04-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-06 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-03-20 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-07-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-08 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-08 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2020-07-08 07:53:29 | NO FEES DUE - SEE 19051045 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-03-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-03-20 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-03-20 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2020-03-20 09:13:35 | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | THANK YOU, | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2020-03-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-20 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-20 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2020-03-20 10:06:05 | NO MECHANICAL PLANS HAVE BEEN SUBMITTED FOR THE | | | PROPOSED PROJECT. | | | THE ARCHITECT IS REQUESTING THAT ALL MECHANICAL WORK BE | | | PERFORMED UNDER A SEPARATE PERMIT. | | | CCOLE- 3/20/20 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-07-13 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-07-13 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2020-07-13 11:34:54 | SEE COMMENTS ON PERMIT 19051045. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-03-11 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-03-11 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2020-03-11 09:01:17 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION | | | MANUAL FOR THE OIL-GUARD SYSTEM. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 2) SHT. P000 - PUMP SCHEDULE - A FULL OPEN VALVE IS | | | REQUIRED ON THE DISCHARGE SIDE OF THE CHECK VALVE IN | | | THE PUMP OR EJECTOR DISCHARGE PIPING BETWEEN THE PUMP | | | OR EJECTOR AND THE GRAVITY DRAINAGE SYSTEM. | | | FBC-PLUMBING SEC. 712.2,1113.1.4. | | | 3) SHOW THE DIMENSIONS OF THE SUMP PIT ON SHT.P000. THE | | | SUMP PIT SHALL COMPLY WITH FBC-PLUMBING SEC.1113.1.2 AS | | | A MINIMUM. | | | 4) THERE ARE TWO COPIES OF SHT. P000. REMOVE THE OLD | | | SHEET FROM THIS SUBMITTAL. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 5) SHT. P000 - SHOW THE REQUIRED FULL OPEN VALVE ON THE | | | SUMP DETAIL. | | | 6) SHTS. P101 & P102 - SOME OF THE STORM DRAINS ARE | | | SHOWN AS 6 INCH ON THE PLAN VIEW YET THE STORM | | | ISOMETRIC TYPICAL DECK DRAIN SECTION ONLY SHOWS 4 INCH | | | PIPE. CLARIFY. | | | 7) SHT. P102 - THERE IS A NOTE AT EACH STAIRWELL THAT | | | STATES "SHEET FLOW DOWN TO FIRST LEVEL FROM COVERED | | | STAIRWELL.REFERENCE CIVIL PLANS FOR STORM DRAINAGE." | | | THERE IS NO INFORMATION REGARDING THIS ON THE CIVIL | | | DRAWINGS IN THIS SUBMITTAL. CLARIFY THIS NOTE.WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 8) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION | | | MANUAL FOR THE SUMP PUMP. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 9) SHT. P000 - SUMP PUMP DETAIL STILL SHOWS THE PUMP | | | DISCHARGE LINE DIRECTLY CONNECTED TO THE STORM SYSTEM. | | | THIS DISCHARGE LINE SHALL BE INDIRECTLY CONNECTED TO | | | THE SANITARY SYSTEM PER FBC-PLUMBING SEC.301.6. | | | 10) THE SANITARY LINE THAT THE PUMP IS DISCHARGING TO | | | APPARENTLY HAS BEEN ABANDONED AND IS CAPPED OFF PER ONE | | | OF MY FIELD INSPECTORS. RESEARCH SHALL BE DONE AND | | | DOCUMENTATION SUBMITTED ON THIS LINE AND VERIFIED BY | | | THE DESIGN PROFESSIONAL AND CONTRACTOR THAT THIS LINE | | | IS STILL ACTIVE.WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-07-13 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-07-13 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2020-07-13 09:33:58 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 07.07.2020 | | | PERMIT NO.: 20030124 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS REQUIRED FOR SITE WORK (PARKING | | | LOT), STRIPING, HARDSCAPE, LIGHTING, LANDSCAPING, | | | IRRIGATION, ETC. | | | | | | 2. ALL APPLICABLE DEVELOPMENT ORDER CONDITIONS, AS | | | SPECIFIED IN RESOLUTION NO. 81-20 SHALL APPLY AND BE | | | SATISFIED IN ACCORDANCE WITH THE TIMEFRAMES SPECIFIED | | | THEREIN. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | 19051045 IS FOR PARKING GARAGE | | | PLEASE ENTER RESULTS IN 20030124 AS WELL FOR THE ANCHOR | | | STORES TO THE SOUTH OF GARAGE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-03-23 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-03-23 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2020-03-23 11:08:44 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 3.23.2020 | | | PERMIT NO.: 19051045 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE SITE PLAN INCLUDED SHALL MATCH THAT WHICH WAS | | | PREPARED FOR THE MINOR DSI AMENDMENT, AS PREPARED BY | | | UDKS. THE SITE PLAN PREPARED BY THE ARCHITECT IS | | | MISSING A LOT OF NECESSARY INFORMATION, MAY NOT BE | | | CONSISTENT WITH THE MINOR DSI AMENDMENT, ETC. | | | | | | 2. THE SITE PLAN NEEDS TO CLEARLY IDENTIFY THE SCOPE OF | | | WORK THAT IS ASSOCIATED WITH THE PERMIT IT IS ASSIGNED | | | TO. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|