Plan Review Details - Permit 20030100
Plan Review Stops For Permit 20030100
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By rmcphers Date 2020-04-15 Time 13:32 Rev Time 0.00
Received By rmcphers Date 2020-04-15 Time 13:32 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2021-08-31 Cont ID  
Sent By rrossano Date 2021-08-31 Time   Rev Time 0.00
Received By rrossano Date 2021-08-31 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-04-13 Cont ID  
Sent By rrossano Date 2020-04-13 Time   Rev Time 0.00
Received By rrossano Date 2020-04-13 Time   Sent To  
Notes
2020-04-13 16:12:00PLEASE ADDRESS ZONING COMMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-18 Cont ID  
Sent By aoliver Date 2022-01-18 Time 11:58 Rev Time 0.00
Received By aoliver Date 2021-11-17 Time 06:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-28 Cont ID  
Sent By lmarchan Date 2021-09-28 Time 08:16 Rev Time 0.00
Received By lmarchan Date 2021-08-23 Time 07:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-05-22 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-08 Time 16:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-12-02 Cont ID  
Sent By ccole Date 2021-12-02 Time 16:13 Rev Time 0.00
Received By ccole Date 2021-12-02 Time 14:23 Sent To  
Notes
2021-12-02 16:17:093RD REVIEW FBC-2020 PLUMBING
 PERMIT- 20030100
 12/2/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COMMENT #2 FROM THE 2ND PLAN REVIEW COPIED BELOW HAS
 NOT BEEN ADDRESSED. PLEASE SUBMIT THE MANUFACTURER?S
 SPECIFICATIONS FOR THE NEW TRASH COMPACTOR TO JUSTIFY
 THE REMOVAL OF THE OIL/WATER SEPARATOR. REFER TO SEC.
 90-203 WPB CODE OF ORDINANCES WHICH PROHIBITS ANY
 PERSON TO DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE,
 SPILL, OR DUMP ANY SUBSTANCE OTHER THAN STORMWATER INTO
 MUNICIPAL STORM WATER SYSTEM.
  
 NEW COMMENT: REGARDING ENGINEER?S RESPONSE THAT ALL
 DRAINAGE HAS BEEN REMOVED. PER WPB FBC 107.2.1, PROVIDE
 CLARIFICATION AS TO WHAT HAS CHANGED THAT AN OIL/WATER
 SEPARATOR IS NO LONGER REQUIRED. PROVIDE MANUFACTURER?S
 EQUIPMENT INSTALLATION AND RECOMMENDATIONS TO SUPPORT.
  
 2) PLEASE NOTE THAT A SEPARATE PERMIT IS REQUIRED FOR
 THE RPZ BACKFLOW PREVENTER. A FL. LICENSED PLUMBING
 CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR
 INSTALLATION OF THE BACKFLOW PREVENTER IN ACCORDANCE
 WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF
 ORDINANCES. THE DEVICE SHALL BE TESTED AND CERTIFIED BY
 THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL INSPECTION
 BY THE BUILDING DEPARTMENT. PLEASE CONTACT THE WPB
 UTILITIES CENTRAL OPERATIONS DEPT.AT 561-822-2210 FOR
 FURTHER INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-09-16 Cont ID  
Sent By pvalenti Date 2021-09-16 Time 15:34 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 15:21 Sent To  
Notes
2021-09-16 15:35:28CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20030100 3111 S DIXIE HWY
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
  
 1. SECOND REQUEST: PLAN SHEET P-1.1 NOTES THAT WATER
 CONNECTIONS TO CM (CIVIL MAIN?). REFER TO CIVIL PLANS
 FOR LATERAL CONNECTION POINTS. PER WPB FBC 107.2.1,
 PROVIDE CIVIL DRAWINGS SHOWING THESE LATERAL CONNECTION
 POINTS. IF THE CIVIL DRAWINGS ARE UNDER A SEPARATE
 PERMIT, A COPY OF THE APPROPRIATE PAGE(S) MAY BE
 SUBMITTED AS REFERENCE ONLY.
  
 2. NEW COMMENT: REGARDING ENGINEER?S RESPONSE THAT ALL
 DRAINAGE HAS BEEN REMOVED. PER WPB FBC 107.2.1, PROVIDE
 CLARIFICATION AS TO WHAT HAS CHANGED THAT AN OIL/WATER
 SEPARATOR IS NO LONGER REQUIRED. PROVIDE MANUFACTURER?S
 EQUIPMENT INSTALLATION AND RECOMMENDATIONS TO SUPPORT.
  
 3. N/A
  
 4. SECOND REQUEST: APPLICATION IS FOR TRASH ENCLOSURE
 #2. PLAN SHEETS SP-TRH AND TRH 1.1 REFERENCE TRASH
 ENCLOSURE #1. PER WPB FBC 107.2.1, CLARIFY AND
 RECONCILE. CLARIFY ON P-1.1 AND REMOVE REFERENCES TO
 WHICHEVER TRASH ENCLOSURE IS NOT PART OF THE PERMIT
 APPLICATION.
 I SEE NOTHING THAT INDICATES ON REVISED P1.1 V2 THAT
 IDENTIFIES TRASH ENCLOSURE #2 AS THE STRUCTURE BEING
 PERMITTED. THE TWO STRUCTURES SHOWN ARE NOT IDENTIFIED
 AS TRASH ENCLOSURE #1 AND TRASH ENCLOSURE #2.
 PER WPB FBC 107.2.1,
 ...A)IDENTIFY EACH OF THE TWO STRUCTURES
 ...B)PROVIDE A NOTE STATING TRASH ENCLOSURE #1 IS NOT
 IN THE SCOPE OF WORK.
  
 5. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE DETAIL AND
 SPECIFICATION FOR RPZ.
  
 6. NEW COMMENT: RE: P-2.0; ALL DRAINAGE APPEARS TO HAVE
 BEEN DELETED. PER WPB FBC 107.2.1, REMOVE ALL NOTES,
 SCHEDULES AND DETAILS THAT REFER TO SAID DRAINAGE.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS
 REQUIRED BY FAC AND FS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20030100 3111 S DIXIE HWY
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-05-22 Cont ID  
Sent By jpearson Date 2020-05-22 Time 12:25 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 15:22 Sent To  
Notes
2020-05-22 09:56:32REVIEWED BY JERRY SMITH.
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20030100 3111 S DIXIE HWY
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 1. PLAN SHEET P-1.1 NOTES THAT WATER CONNECTIONS TO CM
 (CIVIL MAIN?). REFER TO CIVIL PLANS FOR LATERAL
 CONNECTION POINTS. THE SAME NOTES ARE MADE CONCERNING
 SANITARY AND STORM. PER WPB FBC 107.2.1, PROVIDE CIVIL
 DRAWINGS SHOWING THESE LATERAL CONNECTION POINTS.
 PLEASE BE ADVISED THAT PER WPB CCCM, A BACKFLOW
 PREVENTER COMPLYING WITH THE REQUIREMENTS OF WPB CCCM
 AND FBC PL 608 IS REQUIRED ON A WATER SERVICE TO A
 STRUCTURE. PROVIDE THE SAME AS REQUIRED.
 2. RE: PLAN SHEET P-1.1; PER WPB FBC 107.2.1, PROVIDE
 PLANS AND SPECIFICATION FOR DRAW OFF PIPING AND OIL
 STORAGE TANK IN CONJUNCTION WITH THE OIL INTERCEPTOR.
 THE PIPING AND CONNECTION INDICATED AS A VENT ON THE
 PLANS IS INCORRECT. THE CONNECTION IS FOR OIL DRAW OFF,
 NOT FOR VENTING. SEE MANUFACTURER?S SPECIFICATION
 INDICATED ON P-2.0.
 3. RE: PLAN SHEET P-1.1; PER WPB FBC 107.2.1, SHOW TRAP
 PRIMER VALVE INSTALLATION IN THE WATER RISER AND PLAN
 VIEW.
 4. APPLICATION IS FOR TRASH ENCLOSURE #2. PLAN SHEETS
 SP-TRH AND TRH 1.1 REFERENCE TRASH ENCLOSURE #1. PER
 WPB FBC 107.2.1, CLARIFY AND RECONCILE. CLARIFY ON
 P-1.1 AND REMOVE REFERENCES TO WHICHEVER TRASH
 ENCLOSURE IS NOT PART OF THE PERMIT APPLICATION.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS
 REQUIRED BY FAC AND FS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20030100 3111 S DIXIE HWY
  
  
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2021-09-27 Time   Rev Time 0.00
Received By   Date 2021-09-27 Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-12-02 Cont ID  
Sent By ccole Date 2021-12-02 Time 16:19 Rev Time 0.00
Received By ccole Date 2021-12-02 Time 16:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-16 Cont ID  
Sent By pvalenti Date 2021-09-16 Time 15:38 Rev Time 0.00
Received By pvalenti Date 2021-09-16 Time 15:38 Sent To  
Notes
2021-09-16 15:41:38****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW DENIED:
  
 PLAN SHEET P1.1 2ND VERSION HAS DESIGN PROFESSIONAL'S
 DIGITAL SIGNATURE BUT IS NOT 3RD PARTY VERIFIABLE.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-15 Cont ID  
Sent By rmcphers Date 2020-04-15 Time 13:34 Rev Time 0.00
Received By rmcphers Date 2020-04-15 Time 13:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-01-18 Cont ID  
Sent By jroach Date 2022-01-18 Time 09:25 Rev Time 0.00
Received By jroach Date 2022-01-18 Time 09:25 Sent To  
Notes
2022-01-18 09:29:54THE CASA MARA COMMERCIAL PLANNED DEVELOPMENT SHALL BE
 SUBJECT TO ALL DEVELOPMENT ORDER CONDITIONS, AS
 OUTLINED IN RESOLUTION NO. 108-21, APPROVED ON JUNE 1,
 2021, AND AS MAY BE AMENDED.
 _______________________________________________________
 _____________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 P: 561.822.1448 | E: [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2021-09-25 Cont ID  
Sent By jroach Date 2021-09-25 Time 15:08 Rev Time 0.00
Received By jroach Date 2021-09-25 Time 15:08 Sent To  
Notes
2021-09-25 15:10:42ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 09.25.2021
 PERMIT NO.: 20030100
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. [ NOT SATISIFED ] - SITE PLAN PROVIDED DOES NOT
 MATCH THAT WHICH WAS SUBMITTED AS PART OF THE MINOR
 PLANNED DEVELOPMENT (PD) AMENDMENT ON FEBRUARY 12,
 2020. ENSURE THAT ALL PLANS ARE THE LATEST APPROVED
 PLANS.
  
 1.1 [ NEW COMMENT ] - WHILE IT IS UNDERSTOOD THAT THE
 SITE PLAN IS ONLY BEING PROVIDED FOR THE LOCATION OF
 TRASH ENCLOSURE #2, THE SITE PLAN RPOVIDED INDICATES
 DIFFERENT SETBACKS FROM THE PROPERTY LINES, ETC. THAN
 THAT WHICH IS APPROVED AS PART OF THE CASA MARA
 COMMERCIAL PLANNED DEVELOPMENT. IF THE APPROVED SITE
 PLAN IS TO BE REVISED, A MINOR AMENDMENT TO THE CPD
 SHALL BE SUBMITTED TO AND APPROVED BY THE DEVELOPMENT
 SERVICES - PLANNING DIVISION.
  
 2. [ SATISFIED ] - THE PERMIT INDICATES THAT THIS
 PERMIT IS FOR TRASH ENCLOSURE #2, BUT ON SHEET TRH-1.1,
 ALL DETAILS ARE ASSOCIATED WITH TRASH ENCLOSURE #1.
 MAKE SURE THAT ALL PLANS ARE CONSISTENT AND ACCURATELY
 REFLECT THE SCOPE OF THE PERMIT.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-04-10 Cont ID  
Sent By jroach Date 2020-04-10 Time 08:34 Rev Time 0.00
Received By jroach Date 2020-04-10 Time 08:34 Sent To  
Notes
2020-04-10 08:34:16ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 04.10.2020
 PERMIT NO.: 20030100
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. SITE PLAN PROVIDED DOES NOT MATCH THAT WHICH WAS
 SUBMITTED AS PART OF THE MINOR PLANNED DEVELOPMENT (PD)
 AMENDMENT ON FEBRUARY 12, 2020. ENSURE THAT ALL PLANS
 ARE THE LATEST APPROVED PLANS.
  
 2. THE PERMIT INDICATES THAT THIS PERMIT IS FOR TRASH
 ENCLOSURE #2, BUT ON SHEET TRH-1.1, ALL DETAILS ARE
 ASSOCIATED WITH TRASH ENCLOSURE #1. MAKE SURE THAT ALL
 PLANS ARE CONSISTENT AND ACCURATELY REFLECT THE SCOPE
 OF THE PERMIT.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved