Plan Review Details - Permit 20030099
Plan Review Stops For Permit 20030099
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-15 Cont ID  
Sent By rmcphers Date 2020-09-15 Time 15:15 Rev Time 0.00
Received By rmcphers Date 2020-09-15 Time 15:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-04-20 Cont ID  
Sent By rmcphers Date 2020-04-20 Time 13:45 Rev Time 0.00
Received By rmcphers Date 2020-04-20 Time 11:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-04-21 Cont ID  
Sent By jleahy Date 2020-04-21 Time 09:02 Rev Time 0.00
Received By jleahy Date 2020-04-21 Time 08:09 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2020-05-04 Cont ID  
Sent By rrossano Date 2020-05-04 Time   Rev Time 0.00
Received By rrossano Date 2020-05-04 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-22 Cont ID  
Sent By ccarvaja Date 2020-09-22 Time 14:49 Rev Time 0.00
Received By ccarvaja Date 2020-09-09 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-09 Cont ID  
Sent By rmcdouga Date 2020-07-09 Time 15:56 Rev Time 0.00
Received By rmcdouga Date 2020-06-23 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-05-15 Cont ID  
Sent By lmarchan Date 2020-05-15 Time 13:14 Rev Time 0.00
Received By lmarchan Date 2020-04-07 Time 11:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-09-14 Cont ID  
Sent By lcrespo Date 2020-09-14 Time 11:30 Rev Time 0.00
Received By lcrespo Date 2020-09-14 Time 11:30 Sent To  
Notes
2020-09-14 11:31:249/14/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-07-09 Cont ID  
Sent By jsmith Date 2020-07-09 Time 15:45 Rev Time 0.00
Received By rmcdouga Date 2020-07-09 Time 12:16 Sent To  
Notes
2020-07-09 12:17:26CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 20030099 3111 S DIXIE HWY
  
 PLUMBING COMMENTS: DENIED
 ENGINEER HAS REMOVED ALL DRAINAGE PIPING, FLOOR DRAINS,
 TRENCH DRAINS AND THE OIL INTERCEPTOR FROM THE PLANS
 AND PROVIDED A NOTE ON PLAN SHEET P-2.0 REGARDING THE
 DISCHARGE OF LIQUID WASTE FROM THE TRASH COMPACTOR.
 THERE IS NO ISSUE TAKEN WITH THIS CONCEPT. THE NOTE
 NEEDS TO BE REVISED TO REFLECT THE FACT THAT THERE WILL
 BE NO DRAINS AS IT SUGGESTS DISCHARGE TO TRENCH DRAIN.
 HOWEVER, THE ARCHITECTURAL PLANS DO NOT IN ANY WAY
 ADDRESS THE THE DRAINAGE ISSUE IN THE STRUCTURE NOW
 THAT THE DRAINS HAVE BEEN REMOVED. PER WPB FBC 107.2.1,
 PROVIDE ARCHITECTURAL DRAWINGS THAT ALLOW FOR RUNOFF OF
 WATER FROM THE FLOORS IN A WAY THAT IS COMPLIANT WITH
 ALL PROVISIONS OF THE FLORIDA BUILDING CODE INCLUDING,
 BUT NOT LIMITED TO FBC AND FBC PL
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20030099 3111 S DIXIE HWY
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-04-22 Cont ID  
Sent By tklarge Date 2020-04-22 Time 11:15 Rev Time 0.00
Received By tklarge Date 2020-04-22 Time 09:31 Sent To  
Notes
2020-04-22 11:10:081) INDICATE ON THE PLAN WHAT TYPE OF LIQUID WASTE WILL
 BE DISCHARGED INTO THE TRENCH DRAIN. IF THERE IS A
 POSSIBILITY OF ANY OF THE LIQUID WASTE FROM THE TRASH
 COMPACTOR DISCHARGING INTO THE TRENCH DRAIN, THEN THE
 TRENCH DRAIN MUST DISCHARGE TO THE OIL INTERCEPTOR AND
 NOT TO THE STORM DRAINAGE SYSTEM. 2017 FBC-PLUMBING
 SEC.1003.1, 1003.4.1.
 2) THE SAMPLING PORTS ARE REQUIRED TO BE 4 INCHES IN
 DIAMETER WHICH WOULD ALSO REQUIRE THE DRAIN FROM THE
 INTERCEPTORS TO BE 4 INCHES IN DIAMETER. A FOUR INCH
 SAMPLING PORT AND DRAIN IS REQUIRED SO THE CITY OF WEST
 PALM BEACH UTILITIES DEPARTMENT HAS AMPLE ROOM FOR
 THEIR EQUIPMENT TO TAKE SAMPLES.
 3) THE OIL SEPARATOR SHALL HAVE A DEPTH OF NOT LESS
 THAN 2 FEET BELOW THE INVERT OF THE DISCHARGE DRAIN PER
 2017 FBC SEC. 1003.4.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-15 Cont ID  
Sent By rmcphers Date 2020-09-15 Time 15:15 Rev Time 0.00
Received By rmcphers Date 2020-09-15 Time 15:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-09 Cont ID  
Sent By rmcdouga Date 2020-07-09 Time 15:56 Rev Time 0.00
Received By rmcdouga Date 2020-07-09 Time 15:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-20 Cont ID  
Sent By rmcphers Date 2020-04-20 Time 13:45 Rev Time 0.00
Received By rmcphers Date 2020-04-20 Time 13:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-09-22 Cont ID  
Sent By jroach Date 2020-09-22 Time 13:49 Rev Time 0.00
Received By jroach Date 2020-09-22 Time 13:44 Sent To  
Notes
2020-09-22 13:49:19THIS REVIEW IS FOR TRASH ENCLOSURE #1 ONLY!
 _______________________________________________________
 _____________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 P: 561.822.1448 | E: [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2020-05-15 Cont ID  
Sent By jroach Date 2020-05-15 Time 11:51 Rev Time 0.00
Received By jroach Date 2020-05-15 Time 11:51 Sent To  
Notes
2020-05-15 11:52:22THIS REVIEW IS FOR TRASH ENCLOSURE #1 ONLY!
 _______________________________________________________
 _____________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 P: 561.822.1448 | E: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved