| Plan Review Stops For Permit 20030099 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-04-20 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-20 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-04-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-04-21 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-04-21 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2020-05-04 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-05-04 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-09-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2020-09-09 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-09 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-06-23 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-05-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-05-15 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-07 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-14 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-14 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2020-09-14 11:31:24 | 9/14/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-07-09 |
|
|
Cont ID |
|
| Sent By |
jsmith |
Date |
2020-07-09 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-09 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2020-07-09 12:17:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 20030099 3111 S DIXIE HWY | | | | | | PLUMBING COMMENTS: DENIED | | | ENGINEER HAS REMOVED ALL DRAINAGE PIPING, FLOOR DRAINS, | | | TRENCH DRAINS AND THE OIL INTERCEPTOR FROM THE PLANS | | | AND PROVIDED A NOTE ON PLAN SHEET P-2.0 REGARDING THE | | | DISCHARGE OF LIQUID WASTE FROM THE TRASH COMPACTOR. | | | THERE IS NO ISSUE TAKEN WITH THIS CONCEPT. THE NOTE | | | NEEDS TO BE REVISED TO REFLECT THE FACT THAT THERE WILL | | | BE NO DRAINS AS IT SUGGESTS DISCHARGE TO TRENCH DRAIN. | | | HOWEVER, THE ARCHITECTURAL PLANS DO NOT IN ANY WAY | | | ADDRESS THE THE DRAINAGE ISSUE IN THE STRUCTURE NOW | | | THAT THE DRAINS HAVE BEEN REMOVED. PER WPB FBC 107.2.1, | | | PROVIDE ARCHITECTURAL DRAWINGS THAT ALLOW FOR RUNOFF OF | | | WATER FROM THE FLOORS IN A WAY THAT IS COMPLIANT WITH | | | ALL PROVISIONS OF THE FLORIDA BUILDING CODE INCLUDING, | | | BUT NOT LIMITED TO FBC AND FBC PL | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE | | | DESIGNER IN ACCORDANCE WITH FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | | | | 20030099 3111 S DIXIE HWY | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-04-22 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-04-22 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2020-04-22 11:10:08 | 1) INDICATE ON THE PLAN WHAT TYPE OF LIQUID WASTE WILL | | | BE DISCHARGED INTO THE TRENCH DRAIN. IF THERE IS A | | | POSSIBILITY OF ANY OF THE LIQUID WASTE FROM THE TRASH | | | COMPACTOR DISCHARGING INTO THE TRENCH DRAIN, THEN THE | | | TRENCH DRAIN MUST DISCHARGE TO THE OIL INTERCEPTOR AND | | | NOT TO THE STORM DRAINAGE SYSTEM. 2017 FBC-PLUMBING | | | SEC.1003.1, 1003.4.1. | | | 2) THE SAMPLING PORTS ARE REQUIRED TO BE 4 INCHES IN | | | DIAMETER WHICH WOULD ALSO REQUIRE THE DRAIN FROM THE | | | INTERCEPTORS TO BE 4 INCHES IN DIAMETER. A FOUR INCH | | | SAMPLING PORT AND DRAIN IS REQUIRED SO THE CITY OF WEST | | | PALM BEACH UTILITIES DEPARTMENT HAS AMPLE ROOM FOR | | | THEIR EQUIPMENT TO TAKE SAMPLES. | | | 3) THE OIL SEPARATOR SHALL HAVE A DEPTH OF NOT LESS | | | THAN 2 FEET BELOW THE INVERT OF THE DISCHARGE DRAIN PER | | | 2017 FBC SEC. 1003.4.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-09 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-09 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-04-20 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-20 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-09-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-09-22 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2020-09-22 13:49:19 | THIS REVIEW IS FOR TRASH ENCLOSURE #1 ONLY! | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-05-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-05-15 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-05-15 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2020-05-15 11:52:22 | THIS REVIEW IS FOR TRASH ENCLOSURE #1 ONLY! | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|