Plan Review Details - Permit 20030019
Plan Review Stops For Permit 20030019
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-05-20 Cont ID  
Sent By rmcphers Date 2020-05-20 Time 08:48 Rev Time 0.00
Received By rmcphers Date 2020-05-20 Time 08:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-05-11 Cont ID  
Sent By rmcphers Date 2020-05-11 Time 11:55 Rev Time 0.00
Received By rmcphers Date 2020-05-11 Time 10:23 Sent To  
Notes
2020-05-11 11:35:29OPEN PORCH ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE A WINDOW SCHEDULE SHOWING WINDOW
 TYPES AND SIZES.
 2) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS AND DOORS.
 3) JOB COST SHOWN ON THE BUILDING PERMIT APPLICATION
 APPEARS TO BE LOW - PLEASE PROVIDE A SIGNED CONTRACT TO
 VERIFY THE COMPLETE JOB COST ( ALL MATERIAL AND LABOR).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-05 Cont ID  
Sent By rmcphers Date 2020-03-05 Time 16:19 Rev Time 0.00
Received By rmcphers Date 2020-03-05 Time 14:17 Sent To  
Notes
2020-03-05 15:53:07WINDOWS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) PLEASE PROVIDE THE ROOFING PRODUCT APPROVALS LISTED
 ON THE DRAWINGS FOR BOTH SLOPE AND LOW SLOPE. ( 2
 COPIES OF EACH) FBC WPB AMENDMENTS 107.2.1.1
 2) FOR THE LOW SLOPE PRODUCT APPROVAL - PLEASE CIRCLE
 THE SYSTEM IN THE PRODUCT APPROVAL TO BE USED AND
 PROVIDE ANY REQUIRED ENGINEERED SIGNED AND SEALED
 ADDITIONAL ATTACHMENT REQUIREMENTS FOR PRESSURES HIGHER
 THAN THE PRODUCT APPROVAL IS DESIGNED FOR. (PLEASE
 REVIEW NOTES ON THE PRODUCT APPROVALS).
 3) PLEASE SHOW THE WIND DESIGN PRESSURES FOR THE
 ROOFING COMPONENTS. FBC WPB AMENDMENTS 107.2.1.1
 4) DRAWING S2 SHOWS ROOF SHEATHING ATTACHED WITH 10D
 RINGSHANK NAILS - DRAWING S3 SHOWS ROOF SHEATHING
 ATTACHED WITH 8D NAILS - PLEASE CLARIFY PER FBC
 R803.2.3.1 (SHOULD BE RING SHANK)
 5) DRAWING A1 HAS NOTES FOR WINDOWS -- PLEASE REMOVE
 THE WINDOW NOTES OR PROVIDE WINDOW SCHEDULES, PRODUCT
 APPROVALS, WIND DESIGN PRESSURES ETC.
 6) PLEASE PROVIDE CEILING FRAMING AND INSULATION
 DETAILS FOR THE FLORIDA ROOM.
 7) PLEASE PROVIDE COMPLETE DETAILS FOR THE GUTTER CUT
 INTO THE RAFTERS - CUTTING AND NOTCHING OF RAFTERS
 NEEDS TO COMPLY WITH FBC R802.7.1.1
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-05-20 Cont ID  
Sent By jpearson Date 2020-05-20 Time 14:51 Rev Time 0.00
Received By jpearson Date 2020-05-20 Time 14:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-05-07 Cont ID  
Sent By jpearson Date 2020-05-07 Time 07:56 Rev Time 0.00
Received By jpearson Date 2020-05-07 Time 07:26 Sent To  
Notes
2020-05-07 07:39:40CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2 (NOT PROVIDED.)
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 (NOT
 PROVIDED.)
 3. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1 (NOT PROVIDED.)
 4. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR RECEPTACLE OUTLETS. RECEPTACLES SHALL
 BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY
 ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6
 FEET FROM A RECEPTACLE OUTLET. THE WALL SPACING
 REQUIREMENTS FOR KITCHEN COUNTER SPACE STATE THAT
 RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT
 ALONG THE WALL LINE IS MORE THAN 24 INCHES MEASURED
 HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE.
 THE PLAN PROVIDED DOES NOT MEET THIS CODE IN SOME
 AREAS. PROVIDE CORRECTION. NEC 210.52(C)(1); FBC RE
 E3901 (NOT PROVIDED.)
 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (NOT
 PROVIDED.)
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS, OR PROVIDE A NOTE REQUIRING
 COMPLIANCE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (NOT
 PROVIDED.)
 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902;
 FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE.
 (NOT PROVIDED.)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-20 Cont ID  
Sent By jpearson Date 2020-03-20 Time 13:15 Rev Time 0.00
Received By jpearson Date 2020-03-20 Time 13:09 Sent To I
Notes
2020-03-20 13:15:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 3. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
 4. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR RECEPTACLE OUTLETS. RECEPTACLES SHALL
 BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY
 ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6
 FEET FROM A RECEPTACLE OUTLET. THE WALL SPACING
 REQUIREMENTS FOR KITCHEN COUNTER SPACE STATE THAT
 RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT
 ALONG THE WALL LINE IS MORE THAN 24 INCHES MEASURED
 HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE.
 THE PLAN PROVIDED DOES NOT MEET THIS CODE IN SOME
 AREAS. PROVIDE CORRECTION. NEC 210.52(C)(1); FBC RE
 E3901
 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS, OR PROVIDE A NOTE REQUIRING
 COMPLIANCE. FBC RE R314.3, R315.1; WPB FBC 107.2.1
 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902;
 FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-05-20 Time   Rev Time 0.00
Received By lmarchan Date 2020-05-20 Time 07:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-14 Cont ID  
Sent By shill Date 2020-05-14 Time 16:13 Rev Time 0.00
Received By ccarvaja Date 2020-04-22 Time 10:49 Sent To  
Notes
2020-05-07 09:44:1805/07/2020 DRAWINGS/SUPPORTING DOCUMENTS UPLOADED TO
 PROJECTDOX. JG.
2020-05-01 15:05:3605/01/2020 CONVERTED TO DIGITAL. JG. (NOTE: PLANS SENT
 TO TEQUESTA FOR SCANNING. PLANS WILL BE UPLOADED TO
 PROJECTDOX WHEN SCANNED)
 05/01/2020 FEES PAID. PLANS BACK IN FOR REVIEW. JG.
  
2020-04-29 08:17:09PLAN REVIEW FEES NOT PAID, REMOVED FROM REVIEW,
 INFORMED APPLICANT
  
  
2020-04-23 16:29:38SENT TO R2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-03-20 Time   Rev Time 0.00
Received By lmarchan Date 2020-03-02 Time 14:16 Sent To  
Notes
2020-03-03 14:17:07R14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2020-05-20 Cont ID  
Sent By rmcphers Date 2020-05-20 Time 08:46 Rev Time 0.00
Received By rmcphers Date 2020-05-20 Time 08:46 Sent To  
Notes
2020-05-20 08:48:00NO ADDED SPACE - RAISING THE ROOF ON EXISTING SPACE
2020-05-20 07:52:315/20 EMAILED IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-05-03 Cont ID  
Sent By shill Date 2020-05-03 Time 09:09 Rev Time 0.00
Received By shill Date 2020-05-03 Time 09:09 Sent To  
Notes
2020-05-03 09:09:16IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2020-05-20 Cont ID  
Sent By rmcphers Date 2020-05-11 Time 13:09 Rev Time 0.00
Received By rmcphers Date 2020-05-11 Time 11:56 Sent To  
Notes
2020-05-11 11:58:49BUILDING VALUE = 183,398.00 / 2 = 91,699.00
 JOB COST = 23,000.00
 PAST 5YRS = 0
2020-04-23 15:47:28FLOOD ZONE AE (BFE:6).

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-05-20 Cont ID  
Sent By rmcphers Date 2020-05-20 Time 11:10 Rev Time 0.00
Received By rmcphers Date 2020-05-20 Time 11:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-05-21 Cont ID  
Sent By jpearson Date 2020-05-21 Time 07:15 Rev Time 0.00
Received By jpearson Date 2020-05-21 Time 07:15 Sent To  
Notes
2020-05-21 07:15:45PER EMAIL FROM RACHEL SARGENT, THE SIGNED/SEALED SHEETS
 ARE IN OFFICE. THEY HAVE NOT BEEN UPLOADED TO THE
 SIGNATURES FOLDER YET, BUT I AM PASSING THE STOP SO THE
 PERMIT CAN BE ISSUED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-05-20 Cont ID  
Sent By jpearson Date 2020-05-20 Time 14:51 Rev Time 0.00
Received By jpearson Date 2020-05-20 Time 14:51 Sent To  
Notes
2020-05-20 14:51:03PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, A
 SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING
 DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1;
 FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-05-07 Cont ID  
Sent By jgomez Date 2020-05-07 Time 09:42 Rev Time 0.00
Received By jgomez Date 2020-05-07 Time 09:41 Sent To  
Notes
2020-05-07 09:42:53CONVERTED TO DIGITAL.
 DRAWINGS WITH ENGINEER'S ORIGINAL SEAL/SIGNATURE ON
 CITY'S FILE. JG

Review Stop Z ZONING
Rev No 2 Status P Date 2020-05-14 Cont ID  
Sent By llouie Date 2020-05-14 Time   Rev Time 0.00
Received By llouie Date 2020-05-14 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-03-12 Cont ID  
Sent By llouie Date 2020-03-12 Time   Rev Time  
Received By llouie Date 2020-03-12 Time   Sent To  
Notes
2020-03-12 09:19:18** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 PROVIDE AN UPDATED SIGNED AND SEALED SURVEY OF THE
 PROPERTY.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  
 * DOES NOT TRIGGER 50% THRESHOLD FOR LANDSCAPE
 IMPROVEMENT (SCOPE OF WORK: $23,000; IMPROVEMENT VALUE
 PER PAPA: $183,398)
  