Plan Review Details - Permit 20021064
Plan Review Stops For Permit 20021064
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-31 Cont ID  
Sent By jgomez Date 2020-03-31 Time 16:28 Rev Time 0.00
Received By jgomez Date 2020-03-31 Time 11:55 Sent To  
Notes
2020-03-31 12:09:40EXISTING MECHANICAL EQUIPMENT:
 MECHANICAL SUB-PERMIT MAY BE REQUIRED WHEN THE
 EQUIPMENT IS REPLACED OR MOVED AND IS NOT IN COMPLIANCE
 WITH THE BUILDING CODE RELATING TO ROOF-MOUNTED
 MECHANICAL UNITS.
 SEC. 102.8 CITY AMENDMENTS AND SEC. 1510.10 FBC.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-26 Cont ID  
Sent By jgomez Date 2020-03-26 Time 09:59 Rev Time 0.00
Received By jgomez Date 2020-03-25 Time 13:18 Sent To  
Notes
2020-03-25 13:30:22RE-ROOF SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- OK
  
 2- DECK REPAIR ENGINEERING CALCULATIONS SUBMITTED;
 A) OK.
  
 B) ENGINEER TO PROVIDE SKETCH SHOWING AREAS WHERE
 REPAIRS ARE REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. NOTE: BECAUSE OF THE
 CURRENT CORONAVIRUS EVENT, HIS CAN BE DONE VIA E-MAIL.
  
 3- STRUCTURAL DECK REPAIRS REQUIRE A SEPARATE PERMIT.
 THIS CAN BE DONE AS A SUB-PERMIT TO THE ROOFING PERMIT.
 NEED A SEPARATE PERMIT APPLICATION FOR THIS SCOPE OF
 WORK. NOTE: THIS WORK CAN NOT BE DONE BY THE ROOFING
 CONTRACTOR UNLESS ROOFING CONTRACTOR POSSESSES THE
 PROPER LICENSE TO PERFORM THIS STRUCTURAL WORK.
  
 RESPONSE:
 REPEAT COMMENT. PERMIT APPLICATION FOR THE STRUCTURAL
 REPAIRS WAS NOT SUBMITTED.
  
 4- PROVIDE COMPLETE FLAT ROOF FLORIDA PRODUCT APPROVAL.
 PRODUCT APPROVAL SUBMITTED IS MISSING THE FLORIDA
 PRODUCT APPROVAL COVER PAGE. THIS PAGE IS REQUIRED
 BECAUSE IT SHOWS THE CURRENT CODE VERSION AND THE
 PRODUCT APPROVAL STATUS. CHAPTER 553 F.S. AND FAC
 61G20-3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. NOTE: BECAUSE OF THE
 CURRENT CORONAVIRUS EVENT, HIS CAN BE DONE VIA E-MAIL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD PERMIT PACKAGE FOR
 REFERENCE). A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By jgomez Date 2020-02-25 Time 14:14 Rev Time 0.00
Received By jgomez Date 2020-02-25 Time 11:16 Sent To  
Notes
2020-02-25 14:32:10RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- NEED A FIELD UPLIFT RESISTANCE TEST (TAS 124) AS
 REQUIRED BY LIMITATION #8 ON PAGE 5 OF 6 OF FLORIDA
 PRODUCT APPROVAL FL16758-R14 SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- DECK REPAIR ENGINEERING CALCULATIONS SUBMITTED;
 A) CALCULATIONS SUBMITTED HAVE A COPY OF A DIGITAL
 SIGNATURE. THIS IS NOT A DIGITAL SUBMITTAL.
 CALCULATIONS NEED TO HAVE THE ORIGINAL SEAL AND
 SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY SEC.
 61G15-23.003 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
 NOTE: THIS APPLIES TO OTHER CALCULATION SUBMITTED BY
 THE SAME ENGINEER (ROOF WIND PRESSURE & ATTACHMENT
 DESIGN, AND ROOF STORM WATER DRAINS CALCULATIONS).
  
 B) ENGINEER TO PROVIDE SKETCH SHOWING AREAS WHERE
 REPAIR ARE REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- STRUCTURAL DECK REPAIRS REQUIRE A SEPARATE PERMIT.
 THIS CAN BE DONE AS A SUB-PERMIT TO THE ROOFING PERMIT.
 NEED A SEPARATE PERMIT APPLICATION FOR THIS SCOPE OF
 WORK. NOTE: THIS WORK CAN NOT BE DONE BY THE ROOFING
 CONTRACTOR UNLESS ROOFING CONTRACTOR POSSESSES THE
 PROPER LICENSE TO PERFORM THIS STRUCTURAL WORK.
  
 4- PROVIDE COMPLETE FLAT ROOF FLORIDA PRODUCT APPROVAL.
 PRODUCT APPROVAL SUBMITTED IS MISSING THE FLORIDA
 PRODUCT APPROVAL COVER PAGE. THIS PAGE IS REQUIRED
 BECAUSE IT SHOWS THE CURRENT CODE VERSION AND THE
 PRODUCT APPROVAL STATUS. CHAPTER 553 F.S. AND FAC
 61G20-3.001.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD PERMIT PACKAGE FOR
 REFERENCE). A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-31 Cont ID  
Sent By jgomez Date 2020-03-31 Time 16:28 Rev Time 0.00
Received By jgomez Date 2020-03-31 Time 11:55 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-26 Cont ID  
Sent By jgomez Date 2020-03-26 Time 09:59 Rev Time 0.00
Received By jgomez Date 2020-03-26 Time 09:59 Sent To I
Notes
2020-03-24 15:33:11RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-25 Cont ID  
Sent By jgomez Date 2020-02-25 Time 14:32 Rev Time 0.00
Received By jgomez Date 2020-02-25 Time 11:13 Sent To I
Notes
***NONE***