Plan Review Details - Permit 20020963
Plan Review Stops For Permit 20020963
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-03 Cont ID  
Sent By rmcdouga Date 2021-09-03 Time 14:00 Rev Time 0.00
Received By rmcdouga Date 2021-09-03 Time 10:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-30 Cont ID  
Sent By dbattles Date 2021-06-30 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2021-06-30 Time 15:53 Sent To  
Notes
2021-06-30 16:08:27PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS THAT WERE SUBMITTED IN THE FILE NAMED,
 CLUBHOUSE SHOPS ENGINEER STAMP.PDF, HAS THE DRAWINGS
 FOR BUILDING I AND NOT THE DRAWINGS FOR THE CLUBHOUSE.
 SUBMIT THE CORRECT DRAWINGS. FBC AMEND. 107.2.1
  
 2) THE ENGINEER IS SELF-CERTIFYING HIS DIGITAL
 SIGNATURE. THE BOARD OF ENGINEERS REQUIRES ENGINEER'S
 DIGITAL SIGNATURES TO BE THIRD PARTY CERTIFIED. FS 471
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-10-05 Cont ID  
Sent By rmcdouga Date 2021-10-05 Time 16:35 Rev Time 0.00
Received By rmcdouga Date 2021-10-05 Time 14:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-09-16 Cont ID  
Sent By lmarchan Date 2021-09-16 Time 09:33 Rev Time 0.00
Received By lmarchan Date 2021-09-14 Time 08:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-03 Cont ID  
Sent By rmcdouga Date 2021-09-03 Time 14:16 Rev Time 0.00
Received By rmcdouga Date 2021-08-19 Time 16:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-30 Cont ID  
Sent By rmcdouga Date 2021-06-30 Time 16:08 Rev Time 0.00
Received By rmcdouga Date 2021-06-16 Time 07:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-10-05 Cont ID  
Sent By rmcdouga Date 2021-10-05 Time 16:35 Rev Time 0.00
Received By rmcdouga Date 2021-10-05 Time 16:35 Sent To  
Notes
2021-10-05 17:13:58SIGNATURE ON PAPER PLANS VERIFIED. SENT TO STORAGE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-09-15 Cont ID  
Sent By pvalenti Date 2021-09-15 Time 16:52 Rev Time 0.00
Received By pvalenti Date 2021-09-15 Time 16:43 Sent To  
Notes
2021-09-15 16:58:07****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW DENIED:
  
 THE ENGINEER?S (CARLOS HERNANDEZ, PE 81309) SIGNATURE
 IS SELF CERTIFIED. THE FLORIDA BOARD OF PROFESSIONAL
 ENGINEERS REQUIRES AN ENGINEER TO OBTAIN A DIGITAL
 SIGNATURE FROM A THIRD?PARTY CERTIFICATION AUTHORITY
 AND THAT IT IS CAPABLE OF VERIFICATION. SEE RULE
 61G15?23.004
 THE 18 PAGES OF DRAWINGS THAT WERE UPLOADED ON
 8/19/2021 ARE SHOWING AS BEENING SIGNED AND
 SELF?CERTIFIED BY KAHLIL CAMPBELL AND THE ENGINEER?S
 NAME ON THE COVERSHEET IS CARLOS HERNANDEZ, PE.
 SUBMIT CLEAN DOCUMENTS THAT HAVE THE VERIFIABLE
 ENGINEER?S DIGITAL SIGNATURE FROM A THIRD PARTY
 CERTIFICATION AGENCY.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-03 Cont ID  
Sent By rmcdouga Date 2021-09-03 Time 14:00 Rev Time 0.00
Received By rmcdouga Date 2021-09-03 Time 10:52 Sent To  
Notes
2021-09-03 14:16:41THE ENGINEER'S (CARLOS HERNANDEZ, PE 81309) SIGNATURE
 IS SELF CERTIFIED. THE FLORIDA BOARD OF PROFESSIONAL
 ENGINEERS REQUIRES AN ENGINEER TO OBTAIN A DIGITAL
 SIGNATURE FROM A THIRD-PARTY CERTIFICATION AUTHORITY
 AND THAT IT IS CAPABLE OF VERIFICATION. SEE RULE
 61G15-23.004
 THE 18 PAGES OF DRAWINGS THAT WERE UPLOADED ON
 8/19/2021 ARE SHOWING AS BEENING SIGNED AND
 SELF-CERTIFIED BY KAHLIL CAMPBELL AND THE ENGINEER'S
 NAME ON THE COVERSHEET IS CARLOS HERNANDEZ, PE.
 SUBMIT CLEAN DOCUMENTS THAT HAVE THE VERIFIABLE
 ENGINEER'S DIGITAL SIGNATURE FROM A THIRD PARTY
 CERTIFICATION AGENCY.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-30 Cont ID  
Sent By rmcdouga Date 2021-06-30 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2021-06-30 Time 15:53 Sent To  
Notes
2021-06-30 15:58:33SOME OF THE SIGNED AND SEALED DOCUMENTS ARE FOR
 BUILDING I AND NOT THE CLUBHOUSE. THE CORRECTED
 DOCUMENTS WILL NEED TO BE REVIEWED FOR SIGNATURE. THE
 ENGINEER IS SELF-CERTIFYING HIS DIGITAL SIGNATURE. THE
 ENGINEER'S BOARD REQUIRES ENGINEER'S DIGITAL SIGNATURES
 TO BE THIRD PARTY CERTIFIED.