| Plan Review Stops For Permit 20020963 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-03 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-03 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-06-30 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-30 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2021-06-30 16:08:27 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS THAT WERE SUBMITTED IN THE FILE NAMED, | | | CLUBHOUSE SHOPS ENGINEER STAMP.PDF, HAS THE DRAWINGS | | | FOR BUILDING I AND NOT THE DRAWINGS FOR THE CLUBHOUSE. | | | SUBMIT THE CORRECT DRAWINGS. FBC AMEND. 107.2.1 | | | | | | 2) THE ENGINEER IS SELF-CERTIFYING HIS DIGITAL | | | SIGNATURE. THE BOARD OF ENGINEERS REQUIRES ENGINEER'S | | | DIGITAL SIGNATURES TO BE THIRD PARTY CERTIFIED. FS 471 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-10-05 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-10-05 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-09-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-16 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-14 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-03 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-19 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-06-30 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-16 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-10-05 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-10-05 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2021-10-05 17:13:58 | SIGNATURE ON PAPER PLANS VERIFIED. SENT TO STORAGE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-09-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-15 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-15 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2021-09-15 16:58:07 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SIGNATURE REVIEW DENIED: | | | | | | THE ENGINEER?S (CARLOS HERNANDEZ, PE 81309) SIGNATURE | | | IS SELF CERTIFIED. THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS REQUIRES AN ENGINEER TO OBTAIN A DIGITAL | | | SIGNATURE FROM A THIRD?PARTY CERTIFICATION AUTHORITY | | | AND THAT IT IS CAPABLE OF VERIFICATION. SEE RULE | | | 61G15?23.004 | | | THE 18 PAGES OF DRAWINGS THAT WERE UPLOADED ON | | | 8/19/2021 ARE SHOWING AS BEENING SIGNED AND | | | SELF?CERTIFIED BY KAHLIL CAMPBELL AND THE ENGINEER?S | | | NAME ON THE COVERSHEET IS CARLOS HERNANDEZ, PE. | | | SUBMIT CLEAN DOCUMENTS THAT HAVE THE VERIFIABLE | | | ENGINEER?S DIGITAL SIGNATURE FROM A THIRD PARTY | | | CERTIFICATION AGENCY. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL | | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-03 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-03 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2021-09-03 14:16:41 | THE ENGINEER'S (CARLOS HERNANDEZ, PE 81309) SIGNATURE | | | IS SELF CERTIFIED. THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS REQUIRES AN ENGINEER TO OBTAIN A DIGITAL | | | SIGNATURE FROM A THIRD-PARTY CERTIFICATION AUTHORITY | | | AND THAT IT IS CAPABLE OF VERIFICATION. SEE RULE | | | 61G15-23.004 | | | THE 18 PAGES OF DRAWINGS THAT WERE UPLOADED ON | | | 8/19/2021 ARE SHOWING AS BEENING SIGNED AND | | | SELF-CERTIFIED BY KAHLIL CAMPBELL AND THE ENGINEER'S | | | NAME ON THE COVERSHEET IS CARLOS HERNANDEZ, PE. | | | SUBMIT CLEAN DOCUMENTS THAT HAVE THE VERIFIABLE | | | ENGINEER'S DIGITAL SIGNATURE FROM A THIRD PARTY | | | CERTIFICATION AGENCY. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-06-30 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-30 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2021-06-30 15:58:33 | SOME OF THE SIGNED AND SEALED DOCUMENTS ARE FOR | | | BUILDING I AND NOT THE CLUBHOUSE. THE CORRECTED | | | DOCUMENTS WILL NEED TO BE REVIEWED FOR SIGNATURE. THE | | | ENGINEER IS SELF-CERTIFYING HIS DIGITAL SIGNATURE. THE | | | ENGINEER'S BOARD REQUIRES ENGINEER'S DIGITAL SIGNATURES | | | TO BE THIRD PARTY CERTIFIED. |
|
|