Plan Review Details - Permit 20020932
Plan Review Stops For Permit 20020932
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-07-20 Cont ID  
Sent By rmcphers Date 2020-07-20 Time 08:56 Rev Time 0.00
Received By rmcphers Date 2020-07-20 Time 08:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-05-28 Cont ID  
Sent By rmcphers Date 2020-05-28 Time 10:40 Rev Time 0.00
Received By rmcphers Date 2020-05-28 Time 09:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-03 Cont ID  
Sent By rmcphers Date 2020-03-03 Time 09:32 Rev Time 0.00
Received By rmcphers Date 2020-03-02 Time 16:38 Sent To  
Notes
2020-03-03 09:32:45SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE REQUIRED ATTIC ACCESS PER FBC R807.1
 2) PLEASE SHOW THE GARAGE FLOOR SURFACE TO SLOPE PER
 FBC R309.1
 3) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT PER
 NOTE ON DRAWING S1.1
 4) PRODUCT APPROVAL PROVIDED FOR THE SINGLE HUNG
 WINDOWS (19-1015.10) IS APPROVED FOR SMALL MISSILE
 IMPACT WHICH WILL REQUIRE SHUTTERS FOR WINDOWS BELOW 30
 FEET FROM GRADE - PLEASE PROVIDE A COMPLETE MIAMI DADE
 OR FLORIDA STATE PRODUCT APPROVAL FOR THE REQUIRED
 SHUTTERS. FBC R301.2.1.2
 5) CANNOT HAVE AN OPENING (DOOR) FROM THE SLEEPING AREA
 TO THE GARAGE PER FBC R302.5.1
 6) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD. FBC WPB
 AMENDMENTS 107.3.4
 7) PLEASE SHOW THE REQUIRED WIND DESIGN PRESSURES FOR
 THE ROOFING (CLADDING AND COMPONENTS). FBC R301.1.3

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2020-07-20 Cont ID  
Sent By jleahy Date 2020-07-20 Time 14:37 Rev Time 0.00
Received By jleahy Date 2020-07-20 Time 14:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2020-05-28 Cont ID  
Sent By jpearson Date 2020-05-28 Time 13:50 Rev Time 0.00
Received By jpearson Date 2020-05-28 Time 10:38 Sent To  
Notes
2020-05-28 13:47:02CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B.
 DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN
 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1
 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND
 FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE
 OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30;
 FBC RE E3704.1, E3706.1
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
 6.CORRECTED.
 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS
 REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR,
 SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE
 E3704.6, 3607.3.1 (SEE NEW COMMENTS.)
 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A
 NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR
 IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC
 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC
 107.2.1 (SEE NEW COMMENTS.)
 9. CORRECTED.
  
 NEW COMMENTS:
  
 10. THE RISER DIAGRAM PROVIDED IS NOT CODE COMPLIANT
 AND IS VERY CONFUSING. IT IS NOT POSSIBLE TO GIVE
 ACCURATE COMMENTS FOR CORRECTION BECAUSE SO MUCH IS
 WRONG WITH THIS DIAGRAM. IT IS RECOMMENDED THAT THE
 ARCHITECT CONTACT THE REVIEWER TO DISCUSS, OR HAVE
 SOMEONE FAMILIAR WITH ELECTRICAL DESIGN DO SO. WPB FBC
 107.2.1
 11. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE
 NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT
 REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN
 AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW
 IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO
 EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)
 THE ADDITIONAL FEE FOR THIS PROJECT WOULD BE $4,150.00
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-05-08 Cont ID  
Sent By ppetty Date 2020-05-08 Time 12:56 Rev Time 0.00
Received By ppetty Date 2020-05-08 Time 12:53 Sent To  
Notes
2020-05-08 12:56:04CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B.
 DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN
 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1
 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND
 FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE
 OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30;
 FBC RE E3704.1, E3706.1
 3.
 4.
 5. .
 6.
 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS
 REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR,
 SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE
 E3704.6, 3607.3.1
 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A
 NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR
 IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC
 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC
 107.2.1
 9.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-19 Cont ID  
Sent By jpearson Date 2020-03-19 Time 15:47 Rev Time 0.00
Received By jpearson Date 2020-03-19 Time 14:48 Sent To  
Notes
2020-03-19 15:11:34CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B.
 DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN
 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1
 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND
 FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE
 OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30;
 FBC RE E3704.1, E3706.1
 3. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2
 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE FOR THE ENTIRE DWELLING UNIT. PROVIDE FULL
 FLOOR PLAN SHOWING ALL EXISTING ALARMS. IF NONE ARE
 EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS, OR
 PROVIDE A NOTE REQUIRING COMPLIANCE. FBC RE R314.3,
 R315.1; WPB FBC 107.2.1
 5. AFCI PROTECTION AS SHOWN IN NOTE 2 IS NOT CODE
 COMPLIANT, KITCHEN AREA IS MISSING FROM THIS NOTE. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 6. IT APPEARS THAT PANEL B IS LOCATED IN A SEPARATE
 STRUCTURE. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE
 REQUIRE A DISCONNECTING MEANS AT THE BUILDING OR
 SEPARATE STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN
 DISCONNECT OR MAIN BREAKER AT THE PANEL FOR PANEL B.
 NEC 225.31, 225.32
 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS
 REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR,
 SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE
 E3704.6, 3607.3.1
 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A
 NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR
 IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC
 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC
 107.2.1
 9. THERE ARE TWO SHEETS IDENTIFIED AS E-1.0. PROVIDE
 EACH SHEET WITH A UNIQUE NAME. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2020-07-06 Cont ID  
Sent By aborngra Date 2020-07-06 Time 15:13 Rev Time 0.00
Received By aborngra Date 2020-07-06 Time 14:54 Sent To  
Notes
2020-07-06 15:13:20CONDITIONAL APPROVAL - LANDSCAPING. LANDSCAPING PERMIT
 MUST BE ISSUED AND INSPECTION OF LANDSCAPING
 INSTALLATION APPROVED PRIOR TO CO BEING ISSUED.
  
 THE FOLLOWING ARE PROPOSED CONDITION(S)
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2020-06-02 Cont ID  
Sent By aborngra Date 2020-06-02 Time 09:52 Rev Time 0.00
Received By aborngra Date 2020-06-02 Time 09:52 Sent To  
Notes
2020-06-02 09:52:32CONDITIONAL APPROVAL - LANDCAPING SINGLE FAMILY IS
 PENDING SUBMISSION BY APPLICANT. THIS REVIEW WILL NOT
 PASS UNTIL DOCUMENT IS RECEIVED.
  
 THE FOLLOWING ARE PROPOSED CONDITION(S)
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2020-05-18 Cont ID  
Sent By aborngra Date 2020-05-18 Time 14:13 Rev Time 0.00
Received By aborngra Date 2020-05-18 Time 14:11 Sent To  
Notes
2020-05-18 14:13:03THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. SUBMIT A LANDSCAPING PERMIT OR COMPLETE THE
 CONDITIONAL PERMIT - LANSCAPING SINGLE FAMILY FORM THAT
 WAS EMAILED ON THURSDAY, MAY 14TH.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS ARE APPROVED,
 SUBJECT TO CHANGE.
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-02-28 Cont ID  
Sent By aborngra Date 2020-02-28 Time 08:53 Rev Time 0.00
Received By aborngra Date 2020-02-27 Time 15:41 Sent To  
Notes
2020-02-28 08:53:28THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. THE PERMIT DESCRIPTION STATES THAT THE PROPOSED
 PERMIT INCLUDES REPLACING WINDOWS IN THE EXISTING
 HOUSE. PROVIDE ADDITIONAL CLARIFICATION INCLUDING A
 WINDOW SCHEDULE.
 2. ILLUSTRATE COMPLIANCE WITH SECTION 94-442(C)(2) A.
 SINGLE FAMILY DWELLING UNITS. IF THE PROJECT DOES NOT
 COMPLY WITH THE RESIDENTIAL LANDSCAPING REQUIREMENTS.
 SUBMIT A LANDSCAPING PERMIT. THIS PERMIT WILL NOT PASS
 HISTORIC AND/OR ZONING REVIEW UNTIL COMPLIANCE IS SHOWN
 OR A LANDSCAPING PERMIT IS SUBMITTED.
  
 HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C
 ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXIVLA
 LACLTRPRARTU_S94-442OPSPLARE
  
 3. ILLUSTRATE ON THE SITE PLAN THAT ALL MECHANICAL
 EQUIPMENT WILL COMPLY WITH SECTION 94-305 (B)(4)
 MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW
 AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18
 INCHES INTO A REQUIRED SIDE SETBACK.
  
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL.
 SUBJECT TO CHANGE
 1. ALL GLASS SHALL BE CLEAR OR CLEAR WITH LOW-E
 COATING. BATHROOM WINDOWS MAY HAVE OBSCURED GLASS.
 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-20 Cont ID  
Sent By jleahy Date 2020-07-20 Time 14:38 Rev Time 0.00
Received By jleahy Date 2020-07-01 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-08 Cont ID  
Sent By aborngra Date 2020-06-02 Time 10:03 Rev Time 0.00
Received By aborngra Date 2020-05-04 Time 15:34 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-23 Cont ID  
Sent By lcrespo Date 2020-03-23 Time 18:58 Rev Time 0.00
Received By lcrespo Date 2020-02-21 Time 10:08 Sent To  
Notes
2020-02-25 10:09:22R30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By shill Date 2020-07-31 Time 14:26 Rev Time 0.00
Received By shill Date 2020-07-31 Time 14:04 Sent To  
Notes
2020-07-31 14:05:05MU 2020 027656
 $384.19 PAID
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-03-03 Cont ID  
Sent By rmcphers Date 2020-03-03 Time 09:34 Rev Time 0.00
Received By rmcphers Date 2020-03-03 Time 09:33 Sent To  
Notes
2020-03-03 09:33:56PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-05-28 Cont ID  
Sent By medwards Date 2020-05-28 Time 08:15 Rev Time 0.00
Received By medwards Date 2020-05-28 Time 07:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-03-13 Cont ID  
Sent By medwards Date 2020-03-13 Time 11:00 Rev Time 0.00
Received By medwards Date 2020-03-12 Time 16:55 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status N Date 2020-05-28 Cont ID  
Sent By rmcphers Date 2020-05-28 Time 10:52 Rev Time 0.00
Received By rmcphers Date 2020-05-28 Time 10:52 Sent To  
Notes
2020-05-28 10:52:47FLOOD ZONE X

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-07-07 Cont ID  
Sent By ccole Date 2020-07-07 Time 10:56 Rev Time 0.00
Received By ccole Date 2020-07-07 Time 10:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-06-02 Cont ID  
Sent By ccole Date 2020-06-02 Time 16:50 Rev Time 0.00
Received By ccole Date 2020-06-02 Time 15:59 Sent To  
Notes
2020-06-02 16:50:392ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20020932
 6/2/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS FROM THE 1ST REVIEW PRINTED BELOW WILL BE
 LABELED AS PASSED OR FAILED PER THE REVISED PLANS.
  
 1) PASSED. ON ISOMETRIC (E1.0) DRAWING KITCHEN SINK
 CANNOT DISCHARGE INTO WET VET OF A BATHROOM GROUP IT
 MUST BE DOWNSTREAM PER THE 2017 FBC SECTION R 3108.1
 HORIZONTAL WET VENT PERMITTED.
  
 2) FAILED. PLEASE SHOW THAT SHOWER PAN IS RECESSED IN
 PS1.0, IF THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE
 LINING PER 2017 FBC SECTION R 2709.2.
  
 SHEETS A1 AND S1: THE SHOWER CURB SHALL BE NOT LESS
 THAN 2" DEEP WHEN MEASURED FROM THE TOP OF THE CURB TO
 THE TOP OF THE DRAIN. IF THE INTENTION IS TO PROVIDE A
 RECESSED SHOWER DRAIN, PLEASE SEE SECTION P2709.2
 EXCEPTION 3: THE FINISHED SHOWER DRAIN SHALL BE
 DEPRESSED A MINIMUM OF 2" BELOW THE SURROUNDING
 FINISHED FLOOR ON THE FIRST FLOOR LEVEL AND THE SHOWER
 RECESS SHALL BE POURED INTEGRALLY WITH THE ADJOINING
 FLOOR.
  
 3) PASSED. THERE ARE 2 E1.0 PAGES PLEASE LABEL TO
 DISTINGUISH IE, EP1.1 PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4) PASSED. A SUB PLUMBING PERMIT IS REQUIRED BY A
 LICENSED CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB
 AMENDMENTS TO THE FBC SEC. 105.1.
  
 5) FAILED. HOW IS CABANA GOING TO HAVE HOT WATER, IF
 FROM MAIN HOUSE AND LINES ARE BEING RAN UNDERGROUND,
 THE HOT ONLY MUST BE INSULATED WITH A MINIMUM R- 3
 INSULATION PER THE 2017 FBC RE SECTION 403.5.3.
  
 SHOW THE LOCATION OF THE WATER HEATER FOR THE CABANA
 AND PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN.
 A) SUBMIT MANUFACTURER'S SPECIFICATIONS- P2801.3 FBC
 RES.
 B) INDICATE HOW ACCESS FOR SERVICE AND REPLACEMENT OF
 THE WATER HEATER WILL BE PROVIDED- SECTION P2801.4.
 C) SHOW THE PAN DRAIN PIPING RUN AND TERMINATION
 LOCATION- P2801.6.2.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-03-23 Cont ID  
Sent By lcrespo Date 2020-03-23 Time 18:58 Rev Time 0.00
Received By lcrespo Date 2020-03-23 Time 18:05 Sent To  
Notes
2020-03-23 18:57:0403/23/2020 PLUMBING 1ST REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON ISOMETRIC (E1.0) DRAWING KITCHEN SINK CANNOT
 DISCHARGE INTO WET VET OF A BATHROOM GROUP IT MUST BE
 DOWNSTREAM PER THE 2017 FBC SECTION R 3108.1 HORIZONTAL
 WET VENT PERMITTED.
  
 2. PLEASE SHOW THAT SHOWER PAN IS RECESSED IN PS1.0, IF
 THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE LINING
 PER 2017 FBC SECTION R 2709.2.
  
 NOTE: SHOWER PAN MUST HAVE A SLOPED MORTAR BED THAT IS
 PRE-PITCHED BENEATH PRIOR TO LINER INSTALLATION OF 1/4"
 IN PER FOOT TOWARD THE DRAIN, MUST HAVE DAM CORNER,
 BACKING AROUND THE PERIMETER AND BEFORE FINAL MORTAR
 APPLICATION PLACE SOME PEA GRAVEL OVER WEEP HOLES SO
 THE MORTAR DOES NOT COVER THEM PER MANUFACTURES
 SPECIFICATIONS. (PLEASE PLACE THIS NOTE IF NOT RECESSED
 AND OR SHOW A DETAIL, IF RECESSED PLEASE INCLUDE SEAT
 IN THE RECESS TOTAL DIMENSION AS SEAT WILL PECULATE
 INTO RECESS OF PAN).
  
 3. THERE ARE 2 E1.0 PAGES PLEASE LABEL TO DISTINGUISH
 IE, EP1.1 PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 5. HOW IS CABANA GOING TO HAVE HOT WATER, IF FROM MAIN
 HOUSE AND LINES ARE BEING RAN UNDERGROUND, THE HOT ONLY
 MUST BE INSULATED WITH A MINIMUM R- 3 INSULATION PER
 THE 2017 FBC RE SECTION 403.5.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-03-03 Cont ID  
Sent By rmcphers Date 2020-03-03 Time 09:35 Rev Time 0.00
Received By rmcphers Date 2020-03-03 Time 09:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-07-31 Cont ID  
Sent By shill Date 2020-07-31 Time 14:28 Rev Time 0.00
Received By shill Date 2020-07-31 Time 14:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-20 Cont ID  
Sent By rmcphers Date 2020-07-20 Time 09:14 Rev Time 0.00
Received By rmcphers Date 2020-07-20 Time 09:14 Sent To  
Notes
2020-07-20 09:09:46DRAWING LABELED "A SHEETS 24 6 A2.PDF" IN PROJECTDOX
 NEEDS TO BE ELECTRONICALLY SIGNED AND SEALED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-05-28 Cont ID  
Sent By medwards Date 2020-05-28 Time 08:48 Rev Time 0.00
Received By medwards Date 2020-05-28 Time 08:17 Sent To  
Notes
2020-05-28 10:43:13SURVEY AND SOIL REPORT NEED TO BE DIGITALLY SIGNED AND
 SEALED. RM
2020-05-28 08:50:19SHEET A3.0 IS MISSING THE DIGITAL SIGNATURE AND SEAL.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 4 Status P Date 2020-07-06 Cont ID  
Sent By aborngra Date 2020-07-06 Time 15:13 Rev Time 0.00
Received By aborngra Date 2020-07-06 Time 15:13 Sent To  
Notes
2020-07-06 15:13:36CONDITIONAL APPROVAL - LANDSCAPING. LANDSCAPING PERMIT
 MUST BE ISSUED AND INSPECTION OF LANDSCAPING
 INSTALLATION APPROVED PRIOR TO CO BEING ISSUED.
  
 THE FOLLOWING ARE PROPOSED CONDITION(S)
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop Z ZONING
Rev No 3 Status F Date 2020-06-02 Cont ID  
Sent By aborngra Date 2020-06-02 Time 09:52 Rev Time 0.00
Received By aborngra Date 2020-06-02 Time 09:50 Sent To  
Notes
2020-06-02 09:52:13CONDITIONAL APPROVAL - LANDCAPING SINGLE FAMILY IS
 PENDING SUBMISSION BY APPLICANT. THIS REVIEW WILL NOT
 PASS UNTIL DOCUMENT IS RECEIVED.
  
 THE FOLLOWING ARE PROPOSED CONDITION(S)
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop Z ZONING
Rev No 2 Status F Date 2020-05-18 Cont ID  
Sent By aborngra Date 2020-05-18 Time 14:13 Rev Time 0.00
Received By aborngra Date 2020-05-18 Time 14:13 Sent To  
Notes
2020-05-18 14:13:16THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. SUBMIT A LANDSCAPING PERMIT OR COMPLETE THE
 CONDITIONAL PERMIT - LANSCAPING SINGLE FAMILY FORM THAT
 WAS EMAILED ON THURSDAY, MAY 14TH.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS ARE APPROVED,
 SUBJECT TO CHANGE.
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF
 THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR
 REPLACEMENT WINDOWS ONLY)
 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING
 REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW
 MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY.
 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE
 AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR
 GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET
 FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS.
 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-28 Cont ID  
Sent By aborngra Date 2020-02-28 Time 08:53 Rev Time 0.00
Received By aborngra Date 2020-02-28 Time 08:53 Sent To PC
Notes
2020-02-28 08:53:49THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. THE PERMIT DESCRIPTION STATES THAT THE PROPOSED
 PERMIT INCLUDES REPLACING WINDOWS IN THE EXISTING
 HOUSE. PROVIDE ADDITIONAL CLARIFICATION INCLUDING A
 WINDOW SCHEDULE.
 2. ILLUSTRATE COMPLIANCE WITH SECTION 94-442(C)(2) A.
 SINGLE FAMILY DWELLING UNITS. IF THE PROJECT DOES NOT
 COMPLY WITH THE RESIDENTIAL LANDSCAPING REQUIREMENTS.
 SUBMIT A LANDSCAPING PERMIT. THIS PERMIT WILL NOT PASS
 HISTORIC AND/OR ZONING REVIEW UNTIL COMPLIANCE IS SHOWN
 OR A LANDSCAPING PERMIT IS SUBMITTED.
  
 HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C
 ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXIVLA
 LACLTRPRARTU_S94-442OPSPLARE
  
 3. ILLUSTRATE ON THE SITE PLAN THAT ALL MECHANICAL
 EQUIPMENT WILL COMPLY WITH SECTION 94-305 (B)(4)
 MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW
 AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18
 INCHES INTO A REQUIRED SIDE SETBACK.
  
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL.
 SUBJECT TO CHANGE
 1. ALL GLASS SHALL BE CLEAR OR CLEAR WITH LOW-E
 COATING. BATHROOM WINDOWS MAY HAVE OBSCURED GLASS.
 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE
 MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE
 SEMI-CONTOURED MUNTIN PROFILE.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  