| Plan Review Stops For Permit 20020932 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-20 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-20 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-28 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-03 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-02 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2020-03-03 09:32:45 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE SHOW THE REQUIRED ATTIC ACCESS PER FBC R807.1 | | | 2) PLEASE SHOW THE GARAGE FLOOR SURFACE TO SLOPE PER | | | FBC R309.1 | | | 3) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT PER | | | NOTE ON DRAWING S1.1 | | | 4) PRODUCT APPROVAL PROVIDED FOR THE SINGLE HUNG | | | WINDOWS (19-1015.10) IS APPROVED FOR SMALL MISSILE | | | IMPACT WHICH WILL REQUIRE SHUTTERS FOR WINDOWS BELOW 30 | | | FEET FROM GRADE - PLEASE PROVIDE A COMPLETE MIAMI DADE | | | OR FLORIDA STATE PRODUCT APPROVAL FOR THE REQUIRED | | | SHUTTERS. FBC R301.2.1.2 | | | 5) CANNOT HAVE AN OPENING (DOOR) FROM THE SLEEPING AREA | | | TO THE GARAGE PER FBC R302.5.1 | | | 6) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD. FBC WPB | | | AMENDMENTS 107.3.4 | | | 7) PLEASE SHOW THE REQUIRED WIND DESIGN PRESSURES FOR | | | THE ROOFING (CLADDING AND COMPONENTS). FBC R301.1.3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-20 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-20 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-28 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-28 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2020-05-28 13:47:02 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B. | | | DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN | | | 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1 | | | 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND | | | FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE | | | OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30; | | | FBC RE E3704.1, E3706.1 | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6.CORRECTED. | | | 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS | | | REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, | | | SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1 (SEE NEW COMMENTS.) | | | 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A | | | NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR | | | IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC | | | 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC | | | 107.2.1 (SEE NEW COMMENTS.) | | | 9. CORRECTED. | | | | | | NEW COMMENTS: | | | | | | 10. THE RISER DIAGRAM PROVIDED IS NOT CODE COMPLIANT | | | AND IS VERY CONFUSING. IT IS NOT POSSIBLE TO GIVE | | | ACCURATE COMMENTS FOR CORRECTION BECAUSE SO MUCH IS | | | WRONG WITH THIS DIAGRAM. IT IS RECOMMENDED THAT THE | | | ARCHITECT CONTACT THE REVIEWER TO DISCUSS, OR HAVE | | | SOMEONE FAMILIAR WITH ELECTRICAL DESIGN DO SO. WPB FBC | | | 107.2.1 | | | 11. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW | | | IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | THE ADDITIONAL FEE FOR THIS PROJECT WOULD BE $4,150.00 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-05-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-05-08 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-05-08 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2020-05-08 12:56:04 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B. | | | DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN | | | 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1 | | | 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND | | | FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE | | | OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30; | | | FBC RE E3704.1, E3706.1 | | | 3. | | | 4. | | | 5. . | | | 6. | | | 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS | | | REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, | | | SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1 | | | 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A | | | NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR | | | IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC | | | 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC | | | 107.2.1 | | | 9. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-19 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-19 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2020-03-19 15:11:34 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B. | | | DEMAND FACTORS ARE NOT PERMITTED ON FEEDERS LESS THAN | | | 100 AMP CAPACITY. NEC 220.82; FBC RE E3602.2.2.1 | | | 2. BASED ON THE LOAD SPECIFIED FOR PANEL B, WHEN DEMAND | | | FACTORS ARE NOT USED, THE PANEL AND FEEDERS WOULD BE | | | OVERLOADED. PROVIDE CORRECTION. NEC 215.2, 220, 408.30; | | | FBC RE E3704.1, E3706.1 | | | 3. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE FOR THE ENTIRE DWELLING UNIT. PROVIDE FULL | | | FLOOR PLAN SHOWING ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS, OR | | | PROVIDE A NOTE REQUIRING COMPLIANCE. FBC RE R314.3, | | | R315.1; WPB FBC 107.2.1 | | | 5. AFCI PROTECTION AS SHOWN IN NOTE 2 IS NOT CODE | | | COMPLIANT, KITCHEN AREA IS MISSING FROM THIS NOTE. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | | 801.2, OR 901.2 AS APPLICABLE. | | | 6. IT APPEARS THAT PANEL B IS LOCATED IN A SEPARATE | | | STRUCTURE. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE | | | REQUIRE A DISCONNECTING MEANS AT THE BUILDING OR | | | SEPARATE STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN | | | DISCONNECT OR MAIN BREAKER AT THE PANEL FOR PANEL B. | | | NEC 225.31, 225.32 | | | 7. FEED TO INTERIOR PANEL A FROM DISCONNECT A IS | | | REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, | | | SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1 | | | 8. FEED TO PANEL B IS SHOWN WITH ONE # 6 CONDUCTOR. A | | | NEUTRAL CONDUCTOR AND AN EQUIPMENT GROUNDING CONDUCTOR | | | IS REQUIRED AT THIS PANEL. PROVIDE CORRECTION. NEC | | | 250.24(C), 250.122; FBC RE E3704.6, 3607.3.1; WPB FBC | | | 107.2.1 | | | 9. THERE ARE TWO SHEETS IDENTIFIED AS E-1.0. PROVIDE | | | EACH SHEET WITH A UNIQUE NAME. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-07-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-07-06 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2020-07-06 15:13:20 | CONDITIONAL APPROVAL - LANDSCAPING. LANDSCAPING PERMIT | | | MUST BE ISSUED AND INSPECTION OF LANDSCAPING | | | INSTALLATION APPROVED PRIOR TO CO BEING ISSUED. | | | | | | THE FOLLOWING ARE PROPOSED CONDITION(S) | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-06-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-06-02 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2020-06-02 09:52:32 | CONDITIONAL APPROVAL - LANDCAPING SINGLE FAMILY IS | | | PENDING SUBMISSION BY APPLICANT. THIS REVIEW WILL NOT | | | PASS UNTIL DOCUMENT IS RECEIVED. | | | | | | THE FOLLOWING ARE PROPOSED CONDITION(S) | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-05-18 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-05-18 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-05-18 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2020-05-18 14:13:03 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. SUBMIT A LANDSCAPING PERMIT OR COMPLETE THE | | | CONDITIONAL PERMIT - LANSCAPING SINGLE FAMILY FORM THAT | | | WAS EMAILED ON THURSDAY, MAY 14TH. | | | | | | THE FOLLOWING ARE PROPOSED CONDITIONS ARE APPROVED, | | | SUBJECT TO CHANGE. | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-02-28 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-02-28 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-02-27 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2020-02-28 08:53:28 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. THE PERMIT DESCRIPTION STATES THAT THE PROPOSED | | | PERMIT INCLUDES REPLACING WINDOWS IN THE EXISTING | | | HOUSE. PROVIDE ADDITIONAL CLARIFICATION INCLUDING A | | | WINDOW SCHEDULE. | | | 2. ILLUSTRATE COMPLIANCE WITH SECTION 94-442(C)(2) A. | | | SINGLE FAMILY DWELLING UNITS. IF THE PROJECT DOES NOT | | | COMPLY WITH THE RESIDENTIAL LANDSCAPING REQUIREMENTS. | | | SUBMIT A LANDSCAPING PERMIT. THIS PERMIT WILL NOT PASS | | | HISTORIC AND/OR ZONING REVIEW UNTIL COMPLIANCE IS SHOWN | | | OR A LANDSCAPING PERMIT IS SUBMITTED. | | | | | | HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C | | | ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXIVLA | | | LACLTRPRARTU_S94-442OPSPLARE | | | | | | 3. ILLUSTRATE ON THE SITE PLAN THAT ALL MECHANICAL | | | EQUIPMENT WILL COMPLY WITH SECTION 94-305 (B)(4) | | | MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW | | | AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18 | | | INCHES INTO A REQUIRED SIDE SETBACK. | | | | | | | | | THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL. | | | SUBJECT TO CHANGE | | | 1. ALL GLASS SHALL BE CLEAR OR CLEAR WITH LOW-E | | | COATING. BATHROOM WINDOWS MAY HAVE OBSCURED GLASS. | | | 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-20 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-01 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-05-08 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-06-02 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-05-04 |
Time |
15:34 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-03-23 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-02-21 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-31 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-31 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2020-07-31 14:05:05 | MU 2020 027656 | | | $384.19 PAID | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-03 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-03 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2020-03-03 09:33:56 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-05-28 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-05-28 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-13 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-03-12 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-28 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-28 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2020-05-28 10:52:47 | FLOOD ZONE X |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-07-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-07 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-07 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-06-02 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-06-02 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2020-06-02 16:50:39 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT- 20020932 | | | 6/2/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | PLAN REVIEW RESULTS: DENIED. | | | | | | COMMENTS FROM THE 1ST REVIEW PRINTED BELOW WILL BE | | | LABELED AS PASSED OR FAILED PER THE REVISED PLANS. | | | | | | 1) PASSED. ON ISOMETRIC (E1.0) DRAWING KITCHEN SINK | | | CANNOT DISCHARGE INTO WET VET OF A BATHROOM GROUP IT | | | MUST BE DOWNSTREAM PER THE 2017 FBC SECTION R 3108.1 | | | HORIZONTAL WET VENT PERMITTED. | | | | | | 2) FAILED. PLEASE SHOW THAT SHOWER PAN IS RECESSED IN | | | PS1.0, IF THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE | | | LINING PER 2017 FBC SECTION R 2709.2. | | | | | | SHEETS A1 AND S1: THE SHOWER CURB SHALL BE NOT LESS | | | THAN 2" DEEP WHEN MEASURED FROM THE TOP OF THE CURB TO | | | THE TOP OF THE DRAIN. IF THE INTENTION IS TO PROVIDE A | | | RECESSED SHOWER DRAIN, PLEASE SEE SECTION P2709.2 | | | EXCEPTION 3: THE FINISHED SHOWER DRAIN SHALL BE | | | DEPRESSED A MINIMUM OF 2" BELOW THE SURROUNDING | | | FINISHED FLOOR ON THE FIRST FLOOR LEVEL AND THE SHOWER | | | RECESS SHALL BE POURED INTEGRALLY WITH THE ADJOINING | | | FLOOR. | | | | | | 3) PASSED. THERE ARE 2 E1.0 PAGES PLEASE LABEL TO | | | DISTINGUISH IE, EP1.1 PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4) PASSED. A SUB PLUMBING PERMIT IS REQUIRED BY A | | | LICENSED CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 105.1. | | | | | | 5) FAILED. HOW IS CABANA GOING TO HAVE HOT WATER, IF | | | FROM MAIN HOUSE AND LINES ARE BEING RAN UNDERGROUND, | | | THE HOT ONLY MUST BE INSULATED WITH A MINIMUM R- 3 | | | INSULATION PER THE 2017 FBC RE SECTION 403.5.3. | | | | | | SHOW THE LOCATION OF THE WATER HEATER FOR THE CABANA | | | AND PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN. | | | A) SUBMIT MANUFACTURER'S SPECIFICATIONS- P2801.3 FBC | | | RES. | | | B) INDICATE HOW ACCESS FOR SERVICE AND REPLACEMENT OF | | | THE WATER HEATER WILL BE PROVIDED- SECTION P2801.4. | | | C) SHOW THE PAN DRAIN PIPING RUN AND TERMINATION | | | LOCATION- P2801.6.2. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-03-23 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-03-23 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2020-03-23 18:57:04 | 03/23/2020 PLUMBING 1ST REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON ISOMETRIC (E1.0) DRAWING KITCHEN SINK CANNOT | | | DISCHARGE INTO WET VET OF A BATHROOM GROUP IT MUST BE | | | DOWNSTREAM PER THE 2017 FBC SECTION R 3108.1 HORIZONTAL | | | WET VENT PERMITTED. | | | | | | 2. PLEASE SHOW THAT SHOWER PAN IS RECESSED IN PS1.0, IF | | | THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE LINING | | | PER 2017 FBC SECTION R 2709.2. | | | | | | NOTE: SHOWER PAN MUST HAVE A SLOPED MORTAR BED THAT IS | | | PRE-PITCHED BENEATH PRIOR TO LINER INSTALLATION OF 1/4" | | | IN PER FOOT TOWARD THE DRAIN, MUST HAVE DAM CORNER, | | | BACKING AROUND THE PERIMETER AND BEFORE FINAL MORTAR | | | APPLICATION PLACE SOME PEA GRAVEL OVER WEEP HOLES SO | | | THE MORTAR DOES NOT COVER THEM PER MANUFACTURES | | | SPECIFICATIONS. (PLEASE PLACE THIS NOTE IF NOT RECESSED | | | AND OR SHOW A DETAIL, IF RECESSED PLEASE INCLUDE SEAT | | | IN THE RECESS TOTAL DIMENSION AS SEAT WILL PECULATE | | | INTO RECESS OF PAN). | | | | | | 3. THERE ARE 2 E1.0 PAGES PLEASE LABEL TO DISTINGUISH | | | IE, EP1.1 PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 5. HOW IS CABANA GOING TO HAVE HOT WATER, IF FROM MAIN | | | HOUSE AND LINES ARE BEING RAN UNDERGROUND, THE HOT ONLY | | | MUST BE INSULATED WITH A MINIMUM R- 3 INSULATION PER | | | THE 2017 FBC RE SECTION 403.5.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-03 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-03 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-31 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-31 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-20 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-20 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2020-07-20 09:09:46 | DRAWING LABELED "A SHEETS 24 6 A2.PDF" IN PROJECTDOX | | | NEEDS TO BE ELECTRONICALLY SIGNED AND SEALED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-05-28 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-05-28 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2020-05-28 10:43:13 | SURVEY AND SOIL REPORT NEED TO BE DIGITALLY SIGNED AND | | | SEALED. RM | | 2020-05-28 08:50:19 | SHEET A3.0 IS MISSING THE DIGITAL SIGNATURE AND SEAL. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-07-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-07-06 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2020-07-06 15:13:36 | CONDITIONAL APPROVAL - LANDSCAPING. LANDSCAPING PERMIT | | | MUST BE ISSUED AND INSPECTION OF LANDSCAPING | | | INSTALLATION APPROVED PRIOR TO CO BEING ISSUED. | | | | | | THE FOLLOWING ARE PROPOSED CONDITION(S) | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-06-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-06-02 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2020-06-02 09:52:13 | CONDITIONAL APPROVAL - LANDCAPING SINGLE FAMILY IS | | | PENDING SUBMISSION BY APPLICANT. THIS REVIEW WILL NOT | | | PASS UNTIL DOCUMENT IS RECEIVED. | | | | | | THE FOLLOWING ARE PROPOSED CONDITION(S) | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-05-18 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-05-18 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-05-18 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2020-05-18 14:13:16 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. SUBMIT A LANDSCAPING PERMIT OR COMPLETE THE | | | CONDITIONAL PERMIT - LANSCAPING SINGLE FAMILY FORM THAT | | | WAS EMAILED ON THURSDAY, MAY 14TH. | | | | | | THE FOLLOWING ARE PROPOSED CONDITIONS ARE APPROVED, | | | SUBJECT TO CHANGE. | | | | | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME AND MATCH THE INSET/LOCATION/PLACEMENT OF | | | THE ORIGINAL WINDOWS. (THIS IS APPLICABLE FOR | | | REPLACEMENT WINDOWS ONLY) | | | 2. ALL EXISTING MULLIONS SHALL REMAIN (UNLESS BEING | | | REMOVED FOR THE ADDITION) OR BE REPLACED WITH A NEW | | | MULLION OF THE SAME WIDTH. | | | 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL | | | HAVE CLEAR GLASS ONLY. NO LOW-E, TINTING, OR PRIVACY. | | | 4. ALL NON-STREET FACING GLASS ON THE FRONT STRUCTURE | | | AND ALL GLASS ON THE REAR STRUCTURE SHALL HAVE CLEAR | | | GLASS OR CLEAR GLASS WITH LOW-E COATING. A NON-STREET | | | FACING BATHROOM MAY HAVE OBSCURED TEXTURED GLASS. | | | 5. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-02-28 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-02-28 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-02-28 |
Time |
08:53 |
Sent To |
PC |
|
| Notes |
| 2020-02-28 08:53:49 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. THE PERMIT DESCRIPTION STATES THAT THE PROPOSED | | | PERMIT INCLUDES REPLACING WINDOWS IN THE EXISTING | | | HOUSE. PROVIDE ADDITIONAL CLARIFICATION INCLUDING A | | | WINDOW SCHEDULE. | | | 2. ILLUSTRATE COMPLIANCE WITH SECTION 94-442(C)(2) A. | | | SINGLE FAMILY DWELLING UNITS. IF THE PROJECT DOES NOT | | | COMPLY WITH THE RESIDENTIAL LANDSCAPING REQUIREMENTS. | | | SUBMIT A LANDSCAPING PERMIT. THIS PERMIT WILL NOT PASS | | | HISTORIC AND/OR ZONING REVIEW UNTIL COMPLIANCE IS SHOWN | | | OR A LANDSCAPING PERMIT IS SUBMITTED. | | | | | | HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C | | | ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXIVLA | | | LACLTRPRARTU_S94-442OPSPLARE | | | | | | 3. ILLUSTRATE ON THE SITE PLAN THAT ALL MECHANICAL | | | EQUIPMENT WILL COMPLY WITH SECTION 94-305 (B)(4) | | | MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW | | | AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18 | | | INCHES INTO A REQUIRED SIDE SETBACK. | | | | | | | | | THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL. | | | SUBJECT TO CHANGE | | | 1. ALL GLASS SHALL BE CLEAR OR CLEAR WITH LOW-E | | | COATING. BATHROOM WINDOWS MAY HAVE OBSCURED GLASS. | | | 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL OGEE | | | MUNTINS. FOR CGI SENTINEL LINE, THIS IS THE | | | SEMI-CONTOURED MUNTIN PROFILE. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | |
|
|