Plan Review Details - Permit 20020841
Plan Review Stops For Permit 20020841
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By cthroop Date 2020-04-29 Time 14:20 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 13:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-26 Cont ID  
Sent By cthroop Date 2020-03-26 Time 07:09 Rev Time 0.00
Received By cthroop Date 2020-03-12 Time 13:17 Sent To  
Notes
2020-03-26 08:05:08PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER ? BUILDING - PX3169
 PLANS EXAMINER ? 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ON PLAN PAGE A-00 INDICATE IN DESIGN CRITERIA IF THE
 COVERED PATIO IS DESIGNED AS AN OPEN OR ENCLOSED
 STRUCTURE.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. PROVIDE STRUCTURAL PLAN WITH DETAILS FOR FOUNDATION,
 WALLS AND ROOF FRAMING.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. ROOFING PERMIT WILL BE REQUIRED.
 PERMITS
 105.1 REQUIRED.
  
 4. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF SYSTEM
 COMPONENTS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 5. EAST ELEVATION ON PLAN PAGE A-03 INDICATES THERE ARE
 EXTERIOR DOORS. PROVIDE FRAMING DETAIL WITH ROUGH
 OPENINGS, DESIGN PRESSURES AND PRODUCT APPROVALS.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 6. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
 WOOD BURNING FIREPLACE.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 7. FLOOR PLAN INDICATES A BBQ GRILL WILL BE INSTALLED.
 WHAT TYPE OF FUEL WILL BE USED. IF NATURAL GAS PROVIDE
 GAS RISER DIAGRAHM. IF REMOVEABLE LP TANK PROVIDE
 DETAIL OF CABINET SHOWING REQUIRED VENTING.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 8. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
 BBQ GRILL.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By jleahy Date 2020-04-29 Time 13:55 Rev Time 0.00
Received By jleahy Date 2020-04-29 Time 13:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-23 Cont ID  
Sent By jleahy Date 2020-03-23 Time 09:11 Rev Time 0.00
Received By jleahy Date 2020-03-22 Time 09:20 Sent To  
Notes
2020-03-23 10:46:09ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) LIGHTS ON COLUMNS NEXT TO THE POOL PLEASE SHOW THE
 DIMENSION OF LIGHTS FROM POOL.
  
 FBC RESIDENTIAL CODE E4203.4 LIGHTS TO BE AT LEAST 5'
 FROM THE INSIDE WALL OF THE POOL AND 12' UP OF GRADE.
  
 2) ALL 15 AND 20 AMPERE RECEPTACLE OUTLETS INSTALLED
 OUTSIDE SHALL HAVE GFCI PROTECTION.
  
 FBC RESIDENTIAL CODE E3902.3
  
 3) NEED TO SUBMIT A PANEL SCHEDULE
  
 FBC RESIDENTIAL CODE E3706.2
  
 4) LOAD CALCULATION REQUIRED FOR ADDITIONAL LOADS.
  
 220.16(A)(1) 2014 NEC
2020-03-22 09:20:34JL

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-04-29 Cont ID  
Sent By cthroop Date 2020-04-29 Time 14:20 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 14:05 Sent To  
Notes
2020-04-29 14:21:08GAS BY SEPERATE PERMIT. PROVIDE CODE COMPLIANT PLAN,
 RISER DIAGRAHM AND TANKLESS WH SPECIFICATIONS. CT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-14 Cont ID  
Sent By cpuell Date 2020-05-14 Time 14:47 Rev Time 0.00
Received By cpuell Date 2020-04-23 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-26 Cont ID  
Sent By cthroop Date 2020-03-26 Time 08:05 Rev Time 0.00
Received By cthroop Date 2020-03-11 Time 16:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By cthroop Date 2020-04-29 Time 14:18 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 13:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-03-25 Cont ID  
Sent By jbaker Date 2020-03-25 Time 14:18 Rev Time 0.00
Received By shill Date 2020-03-25 Time 08:02 Sent To  
Notes
2020-03-25 14:19:03REVIEWED REMOTELY BY JAMES BAKER, PE
 PX3997, PE77268
 561-805-6724
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2020-04-29 Cont ID  
Sent By cthroop Date 2020-04-29 Time 14:18 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 14:05 Sent To  
Notes
2020-04-29 14:19:56ROOFING REQUIRES SEPERATE PERMIT. PROVIDE PRODUCT
 APPROVALS FOR ROOFING SYSTEM COMPONENTS. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-05-19 Cont ID  
Sent By shill Date 2020-05-19 Time 12:15 Rev Time 0.00
Received By shill Date 2020-05-19 Time 12:15 Sent To  
Notes
2020-05-19 12:16:14PAPER ORIGINAL RECEIVED
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-04-29 Cont ID  
Sent By cthroop Date 2020-04-29 Time 14:21 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 13:50 Sent To  
Notes
2020-04-29 14:26:53PLAN REVIEW - DIGITAL SIGNATURE AND SEAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER ? BUILDING - PX3169
 PLANS EXAMINER ? 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 COMMENTS FROM 1ST REVIEW:
  
 ****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS481, PAGES ARE NOT DIGITALLY SIGNED. PAGES LACK THE
 SEAL IMAGE REQUIRED.
  
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE WITH THE
 DIGITAL SIGNATURE FOR THE ARCHITECT.
  
 2ND REVIEW - CT
  
 DIGITAL SIGNATURES AND SEALS
  
 DESIGN PROFESSIONALS
  
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
 OPTION -1:
 RE-SUBMIT PLANS WITH VALID SIGNATURE AND SEAL.
  
 OPTION - 2:
 YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH WET
 SEAL AND SIGNATURE OF DESIGN PROFESSIONAL PRIOR TO
 PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL
 FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT
 SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR
 INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND
 IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING TO
 DOWNLOAD AND PRINT YOUR PLANS.
  
 OPTION - 3:
 YOU MAY MAIL IN A HARD COPY OF PLANS WITH WET SEAL AND
 SIGNATURE. A FINAL INSPECTION HOLD WILL BE PLACED ON
 YOUR PERMIT UNTIL DESIGN PROFESSIONALS SIGNATURE AND
 SEAL ARE VERIFIED.
  
 PLEASE ADVISE
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-03-22 Cont ID  
Sent By shill Date 2020-03-22 Time 10:14 Rev Time 0.00
Received By shill Date 2020-03-22 Time 10:14 Sent To  
Notes
2020-03-22 10:15:44****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS481, PAGES ARE NOT DIGITALLY SIGNED. PAGES LACK THE
 SEAL IMAGE REQUIRED.
  
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE WITH THE
 DIGITAL SIGNATURE FOR THE ARCHITECT.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-05-13 Cont ID  
Sent By awooten Date 2020-05-13 Time   Rev Time 0.00
Received By awooten Date 2020-05-13 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-03-18 Cont ID  
Sent By awooten Date 2020-03-18 Time   Rev Time  
Received By awooten Date 2020-03-18 Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved