Plan Review Details - Permit 20020627
Plan Review Stops For Permit 20020627
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-06-15 Cont ID  
Sent By jgomez Date 2020-06-15 Time 15:04 Rev Time 0.00
Received By jgomez Date 2020-06-15 Time 12:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By jbrooks Date 2020-02-25 Time 08:26 Rev Time 0.00
Received By jbrooks Date 2020-02-25 Time 08:26 Sent To  
Notes
2020-02-25 08:27:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1. SUBMITTED PRODUCT APPROVAL FL17472-R3 HAS BEEN
 REVISED TO FL17472-R4. PLEASE PROVIDE TWO SETS. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3
 2. SUBMITTED PRODUCT APPROVAL FL14608-R8 HAS BEEN
 REVISED TO FL14608-R9. PLEASE PROVIDE TWO SETS. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3
 3. SUBMITTED PRODUCT APPROVAL FL14604-R7 HAS BEEN
 REVISED TO FL14604-R8. PLEASE PROVIDE TWO SETS. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3.
 4. FBC B 107.2.1. REVISE FLOOR PLANS/BUILDING FOOT
 PRINT SHOWING LOCATION OF PROPOSED WINDOWS/DOORS TO BE
 REPLACED AND INCLUDE WINDOW/DOOR TYPE FOR EACH OPENING
 AND ROOM DESIGNATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-06-15 Cont ID  
Sent By jgomez Date 2020-06-15 Time 15:09 Rev Time 0.00
Received By jgomez Date 2020-06-08 Time 14:05 Sent To I
Notes
2020-06-08 14:05:39ROUTED TO BLDG. MISC 1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-25 Cont ID  
Sent By jbrooks Date 2020-02-25 Time 08:27 Rev Time 0.00
Received By jbrooks Date 2020-02-14 Time 14:09 Sent To  
Notes
***NONE***