Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-21 Cont ID  
Sent By jgomez Date 2020-02-21 Time 15:14 Rev Time 0.00
Received By jgomez Date 2020-02-21 Time 15:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-14 Cont ID  
Sent By jgomez Date 2020-02-14 Time 17:19 Rev Time 0.00
Received By jgomez Date 2020-02-14 Time 17:02 Sent To  
Notes
2020-02-14 17:19:46RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- FLAT ROOF NOA 18-0919.12 SUBMITTED: SELECTED
 ASSEMBLY ON PAGE 53 OF 67 DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER
 AND CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7
 ON LAST PAGE OF NOA. NEED THE CALCULATIONS TO MEET THE
 DESIGN PRESSURES REQUIRED BY SEC. R301.2.1
 FBC-RESIDENTIAL.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-21 Cont ID  
Sent By jgomez Date 2020-02-21 Time 15:14 Rev Time 0.00
Received By jgomez Date 2020-02-21 Time 15:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-14 Cont ID  
Sent By jgomez Date 2020-02-14 Time 17:20 Rev Time 0.00
Received By jgomez Date 2020-02-14 Time 13:00 Sent To I
Notes
***NONE***