| Plan Review Stops For Permit 20020611 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2020-04-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-30 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-30 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2020-04-24 17:38:38 | SEE ASBESTOS LETTER SUBMITTED WITH THIS RESUBMITTAL. | | | JG. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-04-07 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-04-07 12:06:04 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-02-24 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-02-24 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2020-02-24 08:20:50 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-04-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-04-30 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-04-30 |
Time |
17:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-04-07 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-04-07 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2020-04-07 12:03:45 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20020611 | | | ADD: 1200 S. FLAGLER DR. / SUITE: 1003 | | | CONT: R & B CONSTRUCTION INC. | | | TEL: 561-346-8996 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. APRIL 07TH/ 2020 | | | ACTION: DENIED. | | | | | | 1) COMPLIED. | | | 2) 2ND ROUND COMMENTS. WITH THE UNIT BEING REMODELED | | | BEING ON THE 10TH FLOOR, AND THE FLOOR FINISHES ARE | | | BEING REMOVED THEN THE NEW FLOORS WILL NEED TO MEET THE | | | 2017 FBC-B CODE, THEY WERE TOTALLY REMOVED NOT A | | | REPAIR. 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | WITH STATING THAT THE STRUCTURAL FLOORS ARE 8 INCH | | | FLOOR SYSTEMS THEN THE TESTING REPORTS COULD BE FOR N 8 | | | INCH SLAB AND NO DROP CEILINGS. SEE THE 3 REQUIREMENTS | | | THAT WILL NEED TO BE MET. | | | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | | 2017) | | | FOR TILE, STONE, MARBLE, AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A 8 INCH | | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 1ST ROUND OF COMMENTS. WITH THE SUITE # 1003 IT APPEARS | | | IS ON THE 1ST FLOOR AND IS EXEMPT FROM THE REQUIREMENTS | | | FOR SOUND INSULATION UNDER THE 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATIVE CODE SECTION 105.2(2). THIS BUILDING IS | | | A HIGH RISE BUILDING AND STILL MEET THE REQUIREMENT | | | FOUND IN THE 2017 FBC-B SECTION 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | PLEASE PROVIDE TO THE CITY THE ACTUAL FLAME SPREAD TEST | | | REPORT. | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX,SFP & CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-02-24 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-02-24 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2020-02-24 09:58:57 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20020611 | | | ADD: 1200 S. FLAGLER DR. / SUITE: 1003 | | | CONT: R & B CONSTRUCTION INC. | | | TEL: 561-346-8996 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. FEB. 24/ 2020 | | | ACTION: DENIED. | | | | | | 1) THE COVERSHEET LIST THE MINIMUM BUILDING TYPE AS AN | | | TYPE II-B CONSTRUCTION. PLEASE NOTE IN AN UNSPRINKLERED | | | R-2 OCCUPANCY THE BUILDING WOULD BE ALLOWED TO BE 4 | | | STORIES. IN THE 2017 FBC-B TABLE 404.4 INDICATES THE | | | BUILDING MUST BE CLASSIFIED AS TYPE I-A CONSTRUCTION. | | | | | | 2) WITH THE SUITE # 1003 IT APPEARS IS ON THE 1ST FLOOR | | | AND IS EXEMPT FROM THE REQUIREMENTS FOR SOUND | | | INSULATION UNDER THE 2017 WEST PALM BEACH AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE | | | CODE SECTION 105.2(2). THIS BUILDING IS A HIGH RISE | | | BUILDING AND STILL MEET THE REQUIREMENT FOUND IN THE | | | 2017 FBC-B SECTION 603.1. EXCEPTION 2. INSULATION | | | INSTALLED BETWEEN A FINISHED FLOOR AND SOLID DECKING | | | WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A | | | FLAME SPREAD INDEX OF NOT MORE THAN 200. PLEASE PROVIDE | | | TO THE CITY THE ACTUAL FLAME SPREAD TEST REPORT. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX,SFP & CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-04-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-13 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-07 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2020-04-13 07:25:39 | PASSED WITH PROVISO FOR LOAD CALCULATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-16 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-16 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2020-03-16 13:43:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN HAS 3 RISER DIAGRAMS ON IT, WHAT IS THE PUPOSE | | | OF THIS? THE LOAD CALCULAITON IS ALSO SHOWN TWICE. | | | REMOVE REDUNDANT INFORMATION. PROVIDE CLARIFICATION. | | | WPB FBC 107.2.1 | | | 2. WIRE FOR FEEDER TO PANEL IS SPECIFIED AS # 2, WHICH | | | IS RATED FOR 115 AMPS. THE LOAD CLACULATION PROVIDED | | | STATES THAT THE LOAD IS 116 AMPS, SO THIS WIRE IS NOT | | | SIZED TO HANDLE THE LOAD. PROVIDE CORRECTION. NEC 240.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-04-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-04-07 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-02-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-02-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-02-21 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2020-02-21 15:25:03 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL | | | AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE | | | FIRE SPRINKLER AND FIRE ALARM SYSTEMS FOR CODE COVERAGE | | | AND COMPLIANCE BY CERTIFIED CONTRACTORS. | | | | | | 2) ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE | | | ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND | | | SHOP DRAWINGS BY CERTIFIED CONTRACTORS. | | | | | | 3) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL | | | REMAIN ACTIVE THROUGHOUT THE DEMO AND CONSTRUCTION | | | PERIODS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-05-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-05-12 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-05-12 |
Time |
11:01 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-05-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-05-08 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-23 |
Time |
17:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-04-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-04-06 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-14 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-04-27 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-27 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-04-08 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-04-08 16:17:58 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #20020611 | | | 4/8/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE 1ST REVIEW COMMENTS LISTED BELOW STILL EXIST. | | | | | | THE ARCHITECT IS NOW INTENDING TO PROVIDE A LETTER ON | | | THE 3RD RESUBMITTAL THAT WILL ADDRESS EXISTING BUILDING | | | CONDITIONS AND THE TECHNICAL INFEASIBILTY OF MEETING | | | THE CURRENT CODES. | | | | | | 1) SHEET M1: PROVIDE RETURN AIR FROM THE BEDROOMS- | | | SECTION 601.6 FBC M. | | | | | | 2) M1: THE KITCHEN RANGE EXHAUST DUCT MUST RUN | | | INDEPENDENTLY AND CANNOT BE LOCATED IN THE SAME SHAFT | | | AS THE TOILET EXHAUST- SECTION 505.3 (12) FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-02-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-26 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-26 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2020-02-26 12:40:44 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #20020611 | | | 2/26/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: PROVIDE RETURN AIR FROM THE BEDROOMS- | | | SECTION 601.6 FBC M. | | | | | | 2) M1: THE KITCHEN RANGE EXHAUST DUCT MUST RUN | | | INDEPENDENTLY AND CANNOT BE LOCATED IN THE SAME SHAFT | | | AS THE TOILET EXHAUST- SECTION 505.3 (12) FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-04-07 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-04-07 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2020-04-07 13:59:48 | 2017 FBC- PLUMBING PLAN REVIEW | | | W. P. B. PERMIT: 20020611 | | | ADD: 1200 S. FLAGLER DR. SUITE: 1003 | | | CONT: R & B CONSTRUCTION INC | | | TEL: 561-346-8996 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. APRIL 07TH/ 2020 | | | ACTION: PLUMBING PROVISO | | | | | | 1) 2017 FBC-P SECTION 504.7.1. THE PAN SHAALL BE | | | DRAINED BY AN INDIRECT WASTE PIPE HAVING A DIAMETER OF | | | NOT LESS THAN 3/4 INCH. | | | PIPING FOR SAFETY PAN DRAINS SHALL BE OF THOSE | | | MATERIALS LISTED IN TABLE 605.4. | | | PLUMBING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-04-07 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2020-03-17 14:21:23 | 2017 FBC- PLUMBING PLAN REVIEW | | | W. P. B. PERMIT: 20020611 | | | ADD: 1200 S. FLAGLER DR. SUITE: 1003 | | | CONT: R & B CONSTRUCTION INC | | | TEL: 561-346-8996 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 17TH/ 2020 | | | ACTION: DENIED | | | | | | 1) SHEET A1.1THE EXISTING FLOOR PLAN AND PROPOSED FLOOR | | | PLAN IT WOULD APPEAR THE RANGE AND KITCHEN SINK HAVE | | | CHANGED LOCATIONS. THE P1 SHEET DOES NOT SHOW A RISER | | | FOR THE NEW LOCATION OF THE KITCHEN SINK FOR SANITARY | | | NOR THE SUPPLY LINES. THE LOCATION OF THE RISER NOR THE | | | SIZE OF THE LATERAL ARE SHOWN ON SHEET P1. | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1 OF THE ADMINISTRATIVE CODE 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) MASTER BATHROOM THE P1 SANITARY RISER INDICATES A | | | NEW TOILET WHEREAS THERE SEEMS TO BE A RELOCATION OF | | | THE TOILET ABOUT 6 INCHES CLOSER TO THE NEW SHOWER | | | ENCLOSURE. THE PLAN DOES NOT INDICATE ANY NEW OR | | | RELOCATED HOLE THROUGH THE FLOOR SLAB AND FIRE | | | RESISTANCE RATING OF THE SLAB AS REQUIRED BY SECTION | | | 307.3 OF THE 2017 FBC-PLUMBING CODE. PENETRATIONS OF | | | FLOOR/ CEILING ASSEMBLIES AND ASSEMBLIES REQUIRED TO | | | HAVE A FIRE-RESISTANCE RATING SHALL BE PROTECTED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING. | | | PLEASE SHOW HOW COMPLIANCE WILL BE ACHIEVED FOR | | | 714.4.1.2 THROUGH- PENETRATION (HORIZONTAL) FIRESTOP | | | SYSTEMS. | | | | | | 3) SHEET P1 RISER P1 SHOWS A NEW TOILET, JUST | | | RELOCATED, WHAT IS MISSING ON THIS RISER ARE THE 2 | | | LAVATORIES (1 NEW) SIZE OF THE LATERAL AND LENGTH OF | | | THE LATERAL TO THE VERTICAL SANITARY. 2017 FBC-P TABLE | | | 710.1(2). | | | | | | 4) SHEET P1 ON THE RISER P2 FOR THE GUEST BATH THE | | | SANITARY RISER ONLY SHOWS THE TUB TO SHOWER CHANGE OF | | | LOCATION, MISSING IS THE WATER CLOSET CHANGE OF | | | LOCATION. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 5) SHEET P1 WITH THE NEW LOCATION OF THE SHOWER AND | | | WATER CLOSET AGAIN MISSING INFORMATION FOR THE | | | THROUGH THE FLOOR AND FIRE RATED FLOOR/CEILING | | | ASSEMBLY, 307.3 OF THE 2017 FBC-PLUMBING CODE. | | | PENETRATIONS OF FLOOR/ CEILING ASSEMBLIES AND | | | ASSEMBLIES REQUIRED TO HAVE A FIRE-RESISTANCE RATING | | | SHALL BE PROTECTED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. PLEASE SHOW HOW COMPLIANCE | | | WILL BE ACHIEVED FOR 714.4.1.2 THROUGH- PENETRATION | | | (HORIZONTAL) FIRESTOP SYSTEMS. | | | | | | 6) SHEET A1.1 ALSO SHOWS THE FOYER AND UTILITY CLOSET | | | BEING REARRANGED. THE LOCATION OF THE STACKED WASHER/ | | | DRYER HAS MOVED BUT THERE IS NO MENTION AS TO HOW OR | | | WHERE THE LATERAL FORM THE WASHER WILL TIE INTO THE | | | VERTICAL WASTE RISER. PLEASE SHOW COMPLIANCE WITH THE | | | 2017 FBC-P SECTION 406.2 THE TRAP AND FIXTURE DRAIN FOR | | | AN AUTOMATIC CLOTHES WASHER STANDPIPE SHALL NOT BE LESS | | | THAN 2 INCHES IN DIAMETER. THE FIXTURE DRAIN FOR THE | | | STANDPIPE SERVING AN AUTOMATIC CLOTHES WASHER SHALL | | | CONNECT TO A 3 INCH OR LARGER DIAMETER FIXTURE BRANCH | | | OR STACK. | | | | | | 7) SHEET P-1 DOES NOT SHOW THE LOCATION OF THE CLOTHES | | | WASHER SHUT OFF VALVES AND IS BLOCKED IN BY THE WATER | | | HEATER ON ONE SIDE AND A WALL ON THE OTHER. THE PLAN | | | DOES NOT SHOW HOW COMPLIANCE WITH THE 2017 FBC-P | | | SECTION 606.3 ACCESS SHALL BE PROVIDED TO ALL SHUT OFF | | | VALVES WITHOUT THE HAVING TO MOVE THE APPLIANCES | | | (CLOTHES WASHER). | | | | | | 8) THE P-1 SHEET DOES NOT SHOW ANY RISERS FOR THE | | | SUPPLY LINES. THE DISHWASHER AND CLOTHES WASHER HAVE | | | QUICK CLOSING VALVES ARE BEING UTILIZED AND NEED TO | | | SHOW COMPLIANCE WITH 604.9 WATER HAMMER ARRESTORS. | | | | | | 9) THE P-1 SHEET SHOWS AN ELECTRIC WATER HEATER DETAIL | | | AND DRAIN PAN. THE PAN DOES NOT SHOW A ? INCH DRAIN | | | PIPE FROM THE PAN. SEE FBC-P SECTION 504.7.1 PAN SIZE | | | AND DRAIN. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | JAMES A. WITMER BN, PX, SFP & CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-05-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-05-12 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-05-12 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2020-05-12 11:05:59 | 05/12/2020 MECHANICAL REVIEW LETTER RECEIVED WITH | | | ARCHITECT'S ORIGINAL SEAL /SIGNATURE. LETTER SENT TO | | | LIBRARY UNDER "DONE" STACK. JG. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-05-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-05-08 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-05-08 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2020-04-24 17:35:40 | ARCHITECT'S MECHANICAL RESPONSE LETTER HAS A COPY OF | | | THE ARCHITECT'S SEAL AND SIGNATURE. JG. | | | | | | NO PLANS SUBMITTED THIS TIME. SEE SIGNATURE REVIEW | | | COMMENTS ON FIRST ROUND. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-04-07 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-04-07 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2020-04-07 06:46:40 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FS471, 481 | | | | | | 1. PAGES ARE NOT DIGITALLY SIGNED. EITHER EMAIL | | | DIGITALLY SIGNED DOCUMENTS TO ME, OR SUBMIT ONE SIGNED | | | AND SEALED ORIGINAL AFTER ALL REVIEWS ARE COMPLETE. | | | (PAPER ORIGINALS ORIGINALLY SUBMITTED HAVE BEEN | | | SUPERSEDED, ALL SHEETS). | | | | | | 2. THE APPLICATION LACKS THE SIGNATURE OF THE QUALIFIER | | | OF R&B CONSTRUCTION INC. THE APPLICATION IS SIGNED BY | | | THE OWNERS ON EACH SIDE (THOMAS DUNN, CINDY DUNN). | | | |
|
|