| Plan Review Stops For Permit 20020408 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-19 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-19 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2020-02-19 15:08:19 | NOT REQUIRED - NEW BUILDING BUILD OUT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-05-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-01 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-01 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-30 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-30 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-19 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2020-02-19 15:07:31 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - | | | 1) NEED CONTRACTOR INFO ON THE BUILDING PERMIT | | | APPLICATION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2020-05-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-12 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-05-12 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-06 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-05-06 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2020-05-06 12:23:46 | TO DATE ONLY NOTE #5 HAS BEEN ADDRESSED SEE FIRST | | | REVIEW FOR ALL PLAN REVIEW NOTES JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-03-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-03-28 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-03-28 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2020-03-28 12:33:50 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | ONLY NOTE #5 FROM THE ORIGINAL REVIEW HAS BEEN | | | ADDRESSED JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-07 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-28 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2020-04-07 15:34:05 | REVIEWED BY JAKE LEAHY. | | 2020-03-28 11:33:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | ONLY PLAN REVIEW NOTE #5 HAS BEEN ADDRESSED. | | | | | | SEE ORIGINAL PLAN REVIEW NOTES FROM 3/2/20 JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-03-02 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-03-02 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2020-03-02 11:14:55 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) VALUE IS LOW FOR THIS TYPE OF BUILDOUT. $200,000 | | | | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2) PAGE E110 | | | A FEW NOTES CALL FOR " BY OWNER" THIS NEEDS TO BE | | | INCLUDED IN THE VALUE OF THE PERMIT. | | | KITCHEN AND KITCHEN AREA SEEMS TO BE MISSING GFCI | | | PROTECTION ON 15 AND 20 AMPR RECEPTACLES. | | | 210.8 (B) OTHER THAN DWELLING UNITS. ALL 125-VOLT, | | | SINGLE-PHASE, | | | 15- AND 20-AMPERE RECEPTACLES INSTA LLED IN THE | | | LOCATIONS SPECIFIED | | | IN 210.8(B)(1) THROUGH (8) SHALL HAVE GROUND-FAULT | | | CIRCUITINTERRUPTER | | | PROTECTION FOR PERSONNEL. (2) KITCHENS (5) SINKS ? | | | WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8 M (6 FT) | | | OF THE OUTSIDE EDGE OF THE SINK, | | | | | | 3) NO PANEL SCHEDULES ARE INCLUDED WITH PLANS. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO | | | ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE | | | IDENTIFICATION SHALL INCLUDE AN APPROVED DEGREE OF | | | DETAIL THAT ALLOWS | | | EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE | | | POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR | | | SWITCHES SHALL BE | | | DESCRIBED ACCORDINGLY. THE IDENTIFICATION SHALL BE | | | INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE | | | FACE OR INSIDE OF THE | | | PANEL DOOR IN THE CASE OF A PANELBOARD AND AT EACH | | | SWITCH OR CIRCUIT BREAKER IN A SWITCHBOARD OR | | | SWITCHGEAR | | | | | | 4) NO LOAD CALCULATION INCLUDED WITH THE PLANS. | | | PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL LOADS. | | | NEC 220 | | | | | | 5) NO FAULT CURRENT CALCULATION FOR AIC RATING INCLUDED | | | WITH THE PLANS. | | | PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT | | | AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC | | | 110.10 | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED | | | WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | | AVAILABLE PER NEC 110.24 | | | PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | | | | 6) PAGE E710 | | | SEPARATE PERMIT REQUIRED FOR UPS SYTEM BY OWNER. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-02-26 |
Time |
0:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2020-02-26 |
Time |
00:00 |
Sent To |
|
|
| Notes |
| 2020-03-10 11:29:04 | PROVISO - COLD SHELL ONLY |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-22 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-22 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2020-05-22 08:08:42 | REVIEWED BY JERRY SMITH. NO CHANGES TO PREVIOUSLY | | | APPROVED GAS PLAN. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2020-04-07 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-03-28 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-02-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-27 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-27 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2020-02-27 11:47:53 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 58 = LIQUIFIED PETROLEUM GAS | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | | | | GAS COMMENTS: DENIED | | | 1. PLANS INDICATE A LPG SYSTEM. PREVIOUSLY ISSUED | | | MASTER PERMIT 19081537 FOR BUILDING SHELL DOES NOT SHOW | | | EVIDENCE OF SEPARATE GAS PERMIT BEING APPLIED FOR AND | | | ISSUED. CONSEQUENTLY THERE IS NO RECORD OF ANY | | | INSTALLATION OF THAT SYSTEM AND AS SUCH THE NOTE ON NEW | | | PERMIT 20020408 SUMITTAL (PLAN PAGE SP101) INDICATING | | | EXISTING 1000 GALLON LP TANK IS INCORRECT. IT SHOULD | | | READ NEW 1000 GALLON LP TANK TO BE PROVIDED UNDER A | | | SEPARATE PERMIT. ADDITIONALLY, THE PIPING NOTED ON MP | | | 19081537 PLAN PAGE P.01 SHALL BE INCORPORATED INTO MP | | | 20020408 AND SHALL CLEARLY INDICATE WHICH WILL BE UNDER | | | THE OLD MP 19081537 AND WHICH IS TO BE UNDER THE NEW | | | PERMIT. ADDITIONALLY, THE ORIGINAL MP DRAWINGS DO NOT | | | PROVIDE FOR LONGEST LENGTH AND LOAD FOR THE 2 PSI | | | PIPING AND CALCULATIONS SHALL BE PROVIDED FOR THE SAME. | | | IF THE STEPDOWN REGULATOR IS IN MP 20020408 SCOPE OF | | | WORK, THEN PROVIDE A DETAIL SHOWING REGULATOR WITH | | | SHUTOFF VALVE, UNION AND DIRT LEG. PROVIDE | | | MANUFACTURE'S SPECIFICATION; REGULATOR SHALL BE RATED | | | FOR OUTDOORS. ALL VERBAGE ALLUDING TO EXISTING SHALL BE | | | REMOVED AND INSTEAD SHALL REFERENCE WORK PROVIDED UNDER | | | MP 19081537. | | | 2. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING'S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. FBC FG | | | 304.9.3 | | | 3. PER WPB FBC 107.2.1 SUBMIT MANUFACTURER'S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT INCLUDING BUT NOT LIMITED TO KITCHEN, WATER | | | HEATER AND ROOFTOP AIR CONDITIONING UNITS. TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND FBC FG | | | 402.2, AND 301.3. GAS APPLIANCES SHALL BE LISTED AND | | | LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | 4. PLAN SHEET A131: KES 13 (GRILL) AND KES 14 (RANGE) | | | INDICATE NATURAL GAS AS FUEL; PLAN SHEET P100 INDICATES | | | FUEL TYPE IS LP. PER WPB FBC 107.2.1, RECONCILE THE TWO | | | PLAN SHEETS. | | | 5. PLAN SHEET P100; GAS RISER NOTES A SECTION OF | | | HORIZONTAL PIPING DOWNSTREAM OF DWH-1 CONNECTION SIZED | | | 1 INCH. SHALL BE 1-1/4 INCH PER FBC FG TABLE 402.4(28). | | | 6. SUBMIT A COMPLETE DETAIL SHOWING THE TYPE, LOCATION, | | | SIZE, TERMINATION POINT, HEIGHT ABOVE THE FINISH ROOF | | | AND ANCHORING DETAILS OF THE GAS VENT(S) PER FBC FG 502 | | | THRU 505 | | | 7. REVISE DETAIL SHOWING THE EMERGENCY HOOD SHUT DOWN | | | SHUT OFF VALVE. EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE | | | SHALL BE BELOW THE CEILING. THE MANUAL SHUTOFF VALVE | | | SHALL BE UPSTREAM. "UNION TO BE DOWN STREAM OF MANUAL | | | VALVE". SECS. 10.4, 10.5 OF NFPA 96-08. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 20020408 7000 OKEECHOBEE BLVD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-05-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-05-07 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-05-06 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-04-23 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-04-07 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-03-26 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-03-10 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-11 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-19 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-19 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2020-02-19 15:09:41 | NOT REQUIRED - BUILD OUT FOR AN EXISTING SHELL BUILDING |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-04-28 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-27 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-30 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-03-30 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-03-30 07:57:22 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT-20020408 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE AC AND HEATING CALCULATIONS REQUIRES THE | | | ELECTRONIC SIGNATURE AND SEAL OF THE ENGINEER WHO | | | PREPARED THE DOCUMENT. FL. STATUTE 471.025 AND SECTION | | | 61G15-23.005 FLORIDA ADMINISTRATIVE CODE. | | | 2) SHEET M100: PROVIDE CFM?S OF EACH SUPPLY AIR GRILL | | | SUPPLIED FROM THE 20/16 DUCT FROM RTU-1 AT THE HOOD | | | AREA. | | | 3) PLEASE INDICATE WHICH SHEET HAS THE GAS APPLIANCE | | | CUT SHEETS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-24 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-24 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2020-02-24 15:01:27 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #20010408 | | | 2/25/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN | | | EXHAUST HOODS, FIRE SUPPRESSION SYSTEMS, AND THE WALKIN | | | COOLER- SECTION 107.2.1 WPB. PLEASE NOTE THAT THE COSTS | | | ASSOCIATED WITH THESE PHASES OF THE PROJECT SHALL BE | | | ALSO BE SEPARATED FROM THE MAIN PERMIT VALUE. PLEASE | | | PROVIDE A COST BREAKDOWN FOR THE ENTIRE PROJECT TO | | | VERIFY ACCURATE PERMIT VALLUE- SECTION 109.3 WPB | | | | | | 2) THE COMCHECK ENERGY COMPLIANCE SUBMITTAL REQUIRES | | | THE ELECTRONIC SIGNATURE AND SEAL OF THE ENGINEER WHO | | | PREPARED THE DOCUMENT- FL. STATUTE 471.025 AND SECTION | | | 61G15-23.005 FLORIDA ADMINISTRATIVE CODE. | | | | | | 3) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | RTU'S IN ACCORDANCE WITH SECTION C403.2.1 FBC EC. | | | | | | 4) SHEET M600: PROVIDE MINIMUM VENTILATION CALCULATIONS | | | FOR ALL OCCUPIED ROOMS AND SPACES- TABLE 403.3.1.1 FBC | | | M. PROVIDE A SCHEDULE ON THE PLAN THAT INDICATES THE | | | REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 5) M600: INDICATE HOW COMBUSTION AIR IS BEING PROVIDED | | | TO THE NEW GAS COOKING APPLIANCES AND PROVIDE | | | CALCULATIONS- SECTION 304 FBC FG. | | | | | | 6) M100 & M600: AUTOMATIC SHUTOFF DAMPERS, EITHER | | | MOTORIZED OR GRAVITY, SHALL BE PROVIDED FOR THE O/A | | | INTAKES- SECTION C403.2.4.3 FBC-EC. | | | | | | 7) M700: PROVIDE DUCT HANGING AND CONNECTION DETAILS | | | PER SMACNA STANDARDS- SECTION 603 FBC M. | | | | | | 8) M100: PROVIDE CONDENSATE DISPOSAL DETAILS FOR THE | | | RTU'S- SECTION 307.2.3 FBC M. | | | | | | 9) M100: PROVIDE ENGINEERING FOR INSTALLATION OF THE | | | RTU'S- SECTION 301.15 FBC M. PLEASE NOTE THAT | | | ENGINEERING FOR THE THE KITCHEN HOOD FANS AND THE | | | WALKIN COOLER CONDENSERS SHALL BE PROVIDED UNDER THE | | | REQUIRED SEPARATE PERMITS. | | | | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | GAS-FIRE COOKING APPLIANCES- SECTION 623.1 FBC FG. | | | | | | 11) ADVISORY: THE KITCHEN HOOD IS UNDER SEPARATE | | | PERMIT, HOWEVER PLEASE BE ADVISED THAT THE TEMPERATURE | | | DIFFERENTIAL BETWEEN THE EXHAUST HOOD MAKEUP AIR AND | | | THE AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 | | | DEGREES F- SECTION 508.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-22 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-22 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2020-05-22 08:08:20 | REVIEWED BY JERRY SMITH. | | | | | | PLUMBING COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | | | | 20020408 7000 OKEECHOBEE BLVD | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-05 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-05 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2020-05-05 08:43:46 | REVIEWED BY JERRY SMITH. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 3RD REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. GENERAL: ARCHITECTURAL RESPONSE TO COMMENT #1 TO | | | PLUMBING COMMENTS PROVIDED BY TIM LARGE DATED 4/7/20 IS | | | NOTED AND PROVIDES COMPLIANCE. | | | HOWEVER, MEP DID NOT RESPOND TO PLUMBING COMMENTS | | | PROVIDED BY TIM LARGE DATED 4/7/20 IN THE RESPONSE | | | LETTER PREPARED BY MR. DENNIS ALT AND DATED 4/16/20; | | | UPON FURTHER REVIEW OF THE PLANS I OFFER THE FOLLOWING: | | | 2. COMMENT #2: THREE COMPARTMENT SINK IS FOR POT WASH | | | AND NOT FOOD PREP; AS SUCH, IT IS NOT SUBJECT TO THE | | | REQUIREMENTS OF FBC PL 802.1.1 WHICH APPLIES TO FOOD | | | PREP SINKS. | | | 3. COMMENT #3: RESPONSE IS REQUIRED. | | | 4. COMMENT #4: IT IS NOTED THAT NOTE 9 ON P110 CALLS | | | FOR A ? INCH VALVED DRAIN FROM HOT FOOD TABLE TO THE | | | FLOOR SINK IN QUESTION. THE TERM SML SEEMS TO APPLY TO | | | KITCHEN EQUIPMENT SCHEDULE AND FLOOR PLAN (SEE A130 AND | | | A131) WHICH DESCRIBES SHELVING. PER WPB FBC 107.2.1, | | | PLEASE CLARIFY; REMOVE THE TERM SML FROM THE SANITARY | | | RISER AND REPLACE WITH THE SYMBOL FOR NOTE 9. | | | 5. COMMENT #5: IT IS NOTED THAT NOTE 10 ON P110 CALLS | | | FOR DRAINS FROM THE TEA TRAY DRAIN AND THE SODA MACHINE | | | TO THE FLOOR SINK IN QUESTION. AS SUCH, THEY ARE NOT | | | REQUIRED TO DISCHARGE TO THE GREASE INTERCEPTOR. PER | | | WPB FBC 107.2.1, PLEASE REMOVE THE TERM UTENSIL COUNTER | | | FROM THE SANITARY RISER AND REPLACE WITH THE SYMBOL FOR | | | NOTE 10. | | | | | | ADDITIONAL COMMENT REGARDING COMMENT #12 OF REVIEW #1 | | | DATED 2/27/20: PLEASE NOTE THAT P110 REV 1 PLAN VIEW | | | CORRECTED THE DEFICIENCY REGARDING THE HORIZONTAL DRY | | | VENT AT THE THREE-COMPARTMENT SINK, BUT THE SANITARY | | | RISER IS STILL NOT COMPLIANT. PER WPB FBC 107.2.1, SHOW | | | COMPLIANCE ON THE SANITARY RISER AND RECONCILE TO THE | | | PLAN VIEW. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE | | | DESIGNER IN ACCORDANCE WITH FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | | | | 20020408 7000 OKEECHOBEE BLVD | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-04-07 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2020-04-07 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-04-06 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2020-04-07 10:17:46 | 1) SHT. A710 - DETAIL #1 - SHOW THE DIMENSIONS OF THE | | | REQUIRED CLEAR FLOOR SPACES FOR THE HANDICAP ACCESSIBLE | | | FIXTURES ON THE PLAN. COMPLY WITH 2017 FBC-ACCESS. | | | SECS. 305, 604.3, 606.2. | | | 2) SHT. P700 - DETAIL #2 - EACH WELL OF THE THREE | | | COMPARTMENT SINK SHALL DISCHARGE INDEPENDENTLY TO A | | | WASTE RECEPTOR. 2017 FBC-PLUMBING SEC.802.1.1. | | | 3) SHT. P 110 - THE RISER SHOWS AN ICE MACHINE | | | DISCHARGING TO THE GREASE WASTE SYSTEM. WASTES THAT DO | | | NOT REQUIRE TREATMENT OR SEPARATION SHALL NOT BE | | | DISCHARGED INTO ANY INTERCEPTOR OR SEPARATOR. | | | FBC-PLUMBING SEC.1003.2. | | | 4) SHT. P110 - IDENTIFY FIXTURE SML ON THE RISER | | | DIAGRAM ON SHT. 110. THIS IS NOT SHOWN ON THE EQUIPMENT | | | SCHEDULE ON SHT. P600. - CLARIFY. | | | 5) SUBMIT ADDITIONAL INFORMATION ON THE INDIRECT WASTE | | | FROM THE UTENSIL COUNTER. IF THIS WASTE CONTAINS ANY | | | GREASE IT SHALL DISCHARGE TO THE GREASE WASTE SYSTEM. | | | FBC-PLUMBING SEC.1003.1.CLARIFY. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-02-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-27 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-25 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2020-02-27 15:41:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. GENERAL: ELIMINATE ALL VERBAGE ALLUDING TO EXISTING | | | WORK. INSTEAD, REFER TO WORK PERFORMED OR TO BE | | | PERFORMED UNDER MP 19081537. | | | 2. PLAN PAGE SP101 INDICATES AN EXISTING 1250 GALLON | | | GREASE TRAP. A PERMIT HAS BEEN ISSUED FOR THE GREASE | | | TRAP AND PIPING OUT OF BUILDING INTO THE INTERCEPTOR | | | AND CONNECTION TO THE SANITARY (SEE MASTER PERMIT | | | 19081537 PLAN PAGE P.01 AND SUB PERMIT 20010671) | | | ADDITIONALLY A SUB PERMIT 20011040 HAS BEEN ISSUED FOR | | | PLUMBING FOR THE SHELL. BOTH DISCIPLINES STILL APPEAR | | | TO BE OPEN. INDICATE ON THE NEW PLANS THAT NEW WORK IS | | | TO BE COORDINATED WITH WORK PERMITTED UNDER MASTER | | | PERMIT 19081537. THERE ARE INCONSISTENCIES BETWEEN MP | | | 19081537 AND NEW MP 20020408. THE PIPING NOTED ON MP | | | 19081537 PLAN PAGE P.01 SHALL BE INCORPORATED INTO NEW | | | MP 20020408 AND SHALL CLEARLY INDICATE WHICH WILL BE | | | UNDER THE OLD MP 19081537 AND WHICH IS TO BE UNDER THE | | | NEW PERMIT. | | | 3. PLAN SHEET P110, NOTE 7; REVISE TO READ ?TO 1250 | | | GALLON INTERCEPTOR INSTALLED UNDER MP 19081537, SUB | | | PERMIT 20010671. REMOVE ALL VERBAGE ALLEGING EXISTING | | | WORK. | | | 4. MP 19081537 PLAN SHEET P.01 INDICATES A BACKFLOW | | | PREVENTER ON THE WATER SERVICE. NOWHERE DOES THERE | | | APPEAR TO BE A SIZE OR LOCATION INDICATED ON THE PLANS | | | FOR EITHER MP 19081537 OR NEW MP 20020408. PER WPB FBC | | | 107.2.1, PROVIDE ON PLAN SHEET SP101, A LOCATION OF THE | | | BACKFLOW PREVENTER WITH A NOTE THAT STATES A SEPARATE | | | PERMIT SHALL BE REQUIRED FOR THE BACKFLOW PREVENTER. | | | 5. REGARDING THE GREASE TRAP; PROVIDE CALCULATIONS TO | | | CONFIRM THAT THE 1250 GALLON GREASE TRAP WILL BE | | | SUFFICIENT FOR THE GREASY WASTE PER WPB FBC 107.2.1. | | | 6. P110, NOTE 5; PROVIDE BACKFLOW PREVENTER AT ICE | | | MACHINE PER FBC PL 608.3. | | | 7. P110, NOTE 6; MOP SINK FAUCET SHALL BE PROVIDED WITH | | | A VACUUM BREAKER PER FBC PL 608.2. | | | 8. P110, NOTE 6 AND 12; CHEMICAL DISPENSER FAUCET SHALL | | | BE PROVIDED WITH A BACKFLOW PREVENTER PER FBC PL 608.3. | | | 9. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S | | | SPECIFICATION/CUT SHEETS ON ALL KITCHEN AND SPECIALTY | | | EQUIPMENT APPURTENANCES THAT CONNECT TO WATER OR | | | DRAINAGE, EITHER DIRECTLY OR INDIRECTLY. | | | 10. LAVATORY TEMPERATURE LIMITING DEVICES SHALL CONFORM | | | TO ASSE 1070 PER FBC PL 416.5. | | | 11. THE HORIZONTAL DRY VENTS CONNECTING TO THE WATER | | | CLOSET FIXTURE DRAINS ARE PROHIBITED PER FBC PL 905.3 | | | (A DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL | | | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN | | | PIPE) AND 905.4 (A DRY VENT SHALL RISE VERTICALLY TO | | | NOT LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD LEVEL | | | RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING | | | VENTED) | | | 12. THE HORIZONTAL DRY VENT CONNECTING TO GREASY WASTE | | | AT THE THREE COMPARTMENT SINK IS PROHIBITED PER FBC PL | | | 905.3 (A DRY VENT CONNECTING TO A HORIZONTAL DRAIN | | | SHALL CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL | | | DRAIN PIPE) AND 905.4 (A DRY VENT SHALL RISE VERTICALLY | | | TO NOT LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD | | | LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING | | | VENTED) | | | 13. PROVIDE SIZING OF THE GREASY WASTE COMPLYING WITH | | | THE REQUIREMENTS OF FBC PL 915.2.2 AND TABLE 915.2.2. | | | 14. PROVIDE SIZING OF THE SANITARY BUILDING DRAIN | | | COMPLYING WITH THE REQUIREMENTS OF FBC PL 710.1 AND | | | TABLE 710.1(1). | | | 15. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS AND TRENCH | | | DRAINS PER FBC PL 1002.4. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 20020408 7000 OKEECHOBEE BLVD | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-22 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-22 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-05-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-01 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-01 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-30 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-19 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-19 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|