Plan Review Details - Permit 20020396
Plan Review Stops For Permit 20020396
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date   Cont ID  
Sent By   Date   Time 07:27 Rev Time 0.00
Received By jwitmer Date 2020-09-09 Time 07:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-06-30 Cont ID  
Sent By jwitmer Date 2020-06-30 Time 13:43 Rev Time 0.00
Received By jwitmer Date 2020-06-30 Time 13:28 Sent To  
Notes
2020-06-25 15:35:1806/25/2020 UPLOADED 2 DRAWINGS & ONE RESUBMITTAL FORM.
 ONE DRAWING HAD A COPY OF THE DIGITAL SIGNATURE AND THE
 OTHER DRAWING HAD NOT SIGNATURE AT ALL. RESUBMITTAL
 PACKAGE SENT TO LIBRARY UNDER "DONE" STACK. JG.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-04-23 Cont ID  
Sent By rmcdouga Date 2020-04-23 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2020-04-23 Time 11:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-03-30 Cont ID  
Sent By pvalenti Date 2020-03-30 Time 14:20 Rev Time 0.00
Received By pvalenti Date 2020-03-30 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-02 Cont ID  
Sent By jwitmer Date 2020-03-02 Time 10:58 Rev Time 0.00
Received By jwitmer Date 2020-03-02 Time 06:30 Sent To  
Notes
2020-03-02 10:57:582017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20020396
 ADD: 4510 GARDEN AVE.
 CONT: UNIVERSAL WORLD CONSTRUCTION
 TEL: 954-317-6771
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY, MARCH 02/2020
 ACTION: DENIED
  
 1) THE RATIONAL ANALYSIS AND ENGINEERING DESIGN
 CALCULATIONS SUBMITTED HAS A COVERSHEET AND 5 NUMBERED
 PAGES. THE NUMBER PAGE ONE IS THE ONLY SHEET THAT IS
 SIGNED AND SEALED BY THE ENGINEER OF RECORD.
  
 FLORIDA ADMINISTRATIVE CODE. 61G15-23.002(2)(B) FL.
 ADMIN. CODE. A COVER SHEET WITH LISTED PAGES OR INDEX
 SHEET FOR ENGINEERING CALCULATIONS AND OR
 SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE
 SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION &
 PREPARATION OF EACH SECTION OF THE ENGINEERING
 SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER
 SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER
 THE COVER SHEET OR INDEX SHEET.
  
 2) SHEET 1 OF THE CALCULATIONS INDICATES THE COLUMN
 HEIGHT OF 5 FEET WHEREAS THE PLANS SHEET DT1 DETAIL # 8
 INDICATES THE COLUMN TO BE 6 FEET 4 INCHES TALL?
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
 DISCREPANCY BETWEEN THE PLAN AND CALCULATIONS.
  
 3) SHEET 1 OF THE CALCULATIONS INDICATES THE BASIC WIND
 VELOCITY OF 170 MPH AND WIND DESIGN OF 115 MPH.
 THE BASIC WIND VELOCITY OF 170 MPH SHOULD IT NOT READ,
 170 MPH VULT THIS WOULD BE FOR CATEGORY II STRUCTURES,
 THE DERATING TO VASD WOULD THEN BE 132 MPH VASD SEE
 FIGURE 1609.3(1). FOR STRUCTURES IN A CATEGORY I
 CLASSIFICATION THE WIND DESIGN WOULD BE 150 MPH VULT
 AND 116 MPH VASD NOT 115 VULT. PLEASE PROVIDE
 ADDITIONAL INFORMATION 107.2.1.2.
  
 4) THE SITE PLAN DOES NOT PROVIDE TO WHAT SCALE THE
 PLANS WERE DRAWN, THEY INDICATE NOT TO SCALE. THE PLAN
 ALSO INDICATES THE POST FOR THE WALL SYSTEM AND
 FOUNDATIONS. THERE ARE FOUNDATIONS ON THE WEST, NORTH
 AND EAST SIDE OF THE PROPERTY THAT EXTEND PAST THE
 PROPERTY LINE AND INTO THE RIGHT OF WAY. THE 2017 FBC-B
 DOES NOT ALLOW FOR FOUNDATIONS PAST THE PROPERTY LINE
 SEE FBC-B 3202.1.1. PLEASE ADJUST THE PLANS FOR ALL
 FOUNDATIONS TO BE WITHIN THE PROPERTY LINE.
  
 5) PLEASE PROVIDE A CURRENT SURVEY LESS THAN A YEAR
 OLD. 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION
 107.3.5.3. MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
  
 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP & CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2020-09-09 Time 07:27 Rev Time 0.00
Received By lmarchan Date 2020-08-24 Time 15:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By kalexand Date 2020-08-23 Time 21:10 Rev Time 0.00
Received By jgomez Date 2020-06-01 Time 15:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-05-08 Cont ID  
Sent By ajones Date 2020-05-08 Time 14:54 Rev Time 0.00
Received By ajones Date 2020-04-13 Time 11:52 Sent To  
Notes
2020-04-21 11:53:56CONVERTED TO DIGITAL. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-30 Cont ID  
Sent By pvalenti Date 2020-03-30 Time 14:21 Rev Time 0.00
Received By pvalenti Date 2020-03-20 Time 14:50 Sent To  
Notes
2020-03-24 09:30:353/24 ROUTED TO BLDG MISC 2
2020-03-20 14:50:34ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-03-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-11 Time 13:07 Sent To  
Notes
2020-02-21 17:55:43ROUTED TO MISC 2 INBOX
2020-02-12 13:07:26ROUTED TO ZONING INBOX

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-09 Cont ID  
Sent By jwitmer Date 2020-09-09 Time 07:27 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-21 Cont ID  
Sent By jgomez Date 2020-04-21 Time 12:23 Rev Time 0.00
Received By jgomez Date 2020-04-21 Time 12:23 Sent To  
Notes
2020-04-21 12:23:57CONVERTED TO DIGITAL.
 DRAWINGS/CALCULATIONS WITH ENGINEER'S ORIGINAL
 SEAL/SIGNATURE ON CITY'S FILE. JG
  

Review Stop Z ZONING
Rev No 4 Status P Date 2020-08-23 Cont ID  
Sent By kalexand Date 2020-08-23 Time 21:10 Rev Time 0.00
Received By kalexand Date 2020-08-21 Time 21:10 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2020-05-08 Cont ID  
Sent By ajones Date 2020-05-08 Time 14:50 Rev Time 0.00
Received By ajones Date 2020-05-08 Time 14:50 Sent To  
Notes
2020-05-08 14:53:575/8/2020- FAILED. THE FENCE AND THE COLUMNS CAN NOT
 EXCEED 48 INCHES WITHIN THE FRONT SETBACK. DECORATIVE
 FEATURES OF THE WALL/FENCE CAN EXCEED THE REQUIRED
 HEIGHT BY 10 PERCENT.
  
 ANGELLA VANN, AICP
 [email protected]
 561-822-1441

Review Stop Z ZONING
Rev No 2 Status F Date 2020-03-24 Cont ID  
Sent By rfalcone Date 2020-03-24 Time 08:53 Rev Time 0.00
Received By rfalcone Date 2020-03-24 Time 08:53 Sent To I
Notes
2020-03-24 08:56:38ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 3/24/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE PROPOSED WALL IS EXCEEDING THE MAXIMUM HEIGHT
 OF 4 FT WITHIN THE FRONT SETBACK. PLEASE REVISE THE
 WALL HEIGHT ALONG GARDEN AVENUE INTO THE PROPERTY 25FT
 TO COMPLY WITH ZONING REGULATIONS.
  
 PURSUANT ZLDR SEC. 94-302(B)RESIDENTIAL FENCE, HEDGE,
 AND WALL LIMITATIONS.
 MAXIMUM HEIGHT. IN RESIDENTIAL DISTRICTS, NO FENCE OR
 WALL SHALL EXCEED SIX FEET IN HEIGHT WITHIN REQUIRED
 SIDE AND REAR SETBACKS. FENCES OR WALLS SHALL NOT BE IN
 EXCESS OF 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT
 SETBACK. HEDGES SHALL NOT EXCEED TEN FEET IN HEIGHT IN
 ANY REQUIRED SETBACK.
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST
 THAT IT BE SENT TO YOU BY EMAILING [email protected]
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-21 Cont ID  
Sent By rfalcone Date 2020-02-21 Time 14:00 Rev Time 0.00
Received By rfalcone Date 2020-02-21 Time 14:00 Sent To I
Notes
2020-02-21 14:01:232/21/2020 FAILED.
  
 PLEASE PROVIDE A SURVEY OF THE SUBJECT SITE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 E-MAIL: [email protected]
 TEL: (561) 822-1442